• Title/Summary/Keyword: 조영 검사

Search Result 846, Processing Time 0.03 seconds

A Study on Efficacy Of Small Examination According to The W/V% Barium Suspension Mixed With Sodium-Carboxy Methyl Cellulose ($BaSO_4$ Mixed CMC-Na 조영제의 특성과 W/V%농도 변화에 따른 경구 소장조영 검사법의 유용성에 관한 연구)

  • Uhm, Joon-Yong;Lee, Eun-Joo;Lee, Yang-Sub;Lee, Won-Hong;Cho, Cheong-Chan;Ryu, Myung-Seon
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.39-44
    • /
    • 2003
  • The aim of this study is to evaluate a efficient w/v% barium suspension and w/v% sodium carboxy methyl cellulose (SCMC) for small bowel examination. Between november 2001 and june 2002, 370 patients were examined small bowel examination with oral administration of barium suspension mixed with SCMC. we classified into six groups including A(fine type 40% $BaSO_4$ mixed 0.5% SCMC and 600 ml 0.5% SCMC administration), B(fine type 30% $BaSO_4$ mixed 0.5% SCMC), C(fine type 20% $BaSO_4$ mixed 0.5% SCMC), D(fine type 25% $BaSO_4$ mixed 0.5% SCMC), E(D mixed coarse type 25% $BaSO_4$ mixed 0.5% SCMC), F(D mixed coarse type 25% $BaSO_4$ mixed 0.75% SCMC). We measured transparency rate of contrast media transit time, administration dose, viscosity and particle size. The transparency rate was higher then 80 kV and 90 kV in 100 kV in the same 20 mAs condition. Transit time was the fastest in A group(mean trans time 56 minutes) and the slowest in E group(mean 100 minutes), Administration dose was the smallest in A group(mean dose 541 ml and the most in E group(mean 1,100 ml), viscosity was the lowest in E(125.1 mpa/s) and the highest in A(375.5 mpa/s), and particle size was $1.0\;{\mu}m$ in A, B, C, and D group, $0.6\;{\mu}m,\;1.0\;{\mu}m,\;10.0\;{\mu}m$ in E, F group. In conclusion, we propose that the efficient condition for small examination is high voltage technique, high density $BaSO_4$, and 0.625% w/v SCMC.

  • PDF

Evaluation of Usefulness of CT Angiography in the Lower Extremity using Heart Rate (심박동 수를 활용한 Lower Extremity CT Angiography 검사의 유용성 평가)

  • Sung-Sik, Kim;Ho-Sung, Park
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.53-62
    • /
    • 2023
  • The purpose of this study is to find an optimized imaging technique and evaluate its usefulness by comparing and analyzing the difference in contrast enhancement of lower extremity artery according to the patient's heart rate during lower extremity Computed Tomography Angiography examination. From January 2022 to August 22nd, 139 outpatients who visited Ajou University Hospital and underwent lower extremity angio CT examination were targeted. According to the heart rate, the groups were divided into four groups: A(HR ≤65), B(65 < HR < 80), C(80≤ HR). In addition, among patients with a heart rate of 65 or less, the heart rate was considered, and the scan was divided into D, E, F group with a delay time. The time of arrival of contrast medium and the average value of contrast enhancement were compared and analyzed. As a result of quantitative evaluation, B and C groups with a heart rate of more than 65 times had better HU values in the popliteal artery than A group (HR ≤ 65), and D group showed better HU improvement effects compared to A group (p<0.001). The comparative analysis with other groups was insignificant. The difference in heart rate affected the angiographic intensity of the lower extremities artery. Therefore, it is effective to apply the appropriate test timing for each patient by using the heart rate during the lower extremity angio CT Scan.

Evaluation of the signal intensity of magnetic resonance angiography in accordance with the dilution rate of the contrast agent (조영제 희석률에 따른 조영증강 자기공명혈관조영검사의 신호강도 평가)

  • Choi, Kwan-Woo;Seo, Sung-Mi;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5124-5130
    • /
    • 2014
  • Dilution of the contrast agent by analyzing the change in the signal intensity during MR angiography in accordance with the viscosity and osmotic pressure minimizes the side effects, and improves the image quality. The contrast agent molarity changes by the dilution of the contrast agent in the blood, as it is injected, which leads to a change in signal intensity. Based on this principle, a phantom was prepared and experiments were performed. After the phantom experiment, a clinical experiment was conducted using the results of the phantom experiment. From November 2013 to January 2014, a group of patients were classified into diluted contrast agent (30 persons) and undiluted (30 persons), and the signal intensity of the cerebral vessels was compared. The signal intensity of the phantom according to the molarity of the contrast agent increased sharply from 0.0125 mmol, reached a peak at 20 mmol, and achieved equilibrium from 200 mmol. Based on the study results, the signal intensity of the blood vessels in the brain through were compared in a clinical experiment. All the brain vessels in the imaging range with diluting a high content of the gadolinium contrast agent showed high signal intensity. This result supports the phantom experiment and means that using the 500mmol diluted contrast agent is better than using 1000mmol undiluted contrast agent because it is easier to approach the 20mmol level needed to achieve the highest signal intensity. This study has significance in that it can minimize the high viscosity and osmotic pressure, which can cause side effects and improve the image quality using the method of the dilution rate.

The Decision of Voiding Cystourethrography in Children with Urinary Tract Infection (소아 요로감염에서 배뇨성 방광 요도 조영술의 결정)

  • Kim, Dong-Woon;Choi, Eung-Sang;Lim, In-Seok
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.203-211
    • /
    • 2007
  • Purpose : We attempted to compare the independent factors such as age, sex, C-reactive protein(CRP), and white blood cell count(WBC) in children with radiologic studies and assess the necessity of performing voiding cystourethrography(VCUG). Method : 98 children who have been diagnosed their first time febrile urinary tract infection from Janurary 2002 to Januray 2005 were enrolled. In all patient, the duration of fever which occurred before and after treatment was recorded, and CRP, WBC, $^{99m}Tc$-2,3-dimercaptosuccinic acid($^{99m}Tc$-DMSA) renal scans, renal ultrasound and VCUG were analyzed. Results : Of the 98 children diagnosed with urinary tract infection(UTI), 52 were male and 46 were female. 18 had abnormalities in VCUG, 17 had abnormalities in kidney ultrasound, and 20 had partial defects or diffuse uptake decrease in $^{99m}Tc$-DMSA renal scans. There were no significant relationship between incidence of radiologic abnormalities and age. The risk of renal scar was significantly higher in children who had a longer febrile period before treatment than in those with shorter period. Both CRP and WBC were significantly elevated in children with the radiological abnormalities. A positive of $^{99m}Tc$-DMSA renal scans and renal ultrasound were highly associated with vesicoureteral reflux(VUR). Conclusion : If there are abnormalities in the kidney ultrasound and $^{99m}Tc$-DMSA renal scan of a child with initial UTI, a VCUG is recommended. Even in cases without abnormal findings in $^{99m}Tc$-DMSA renal scan and renal ultrasound, clinical data such as CRP and WBC should be assessed, and VCUG should be Performed for the undetected VUR.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

The Role of Dynamic CT for the Differential Diagnosis of Solitary Pulmonary Nodule (고립성 폐결절의 감별진단에서 Dynamic CT의 역할)

  • Chung, Jin-Hong;Park, Won-Jong;Cho, Ihn-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.2
    • /
    • pp.102-107
    • /
    • 2008
  • Background : Malignant pulmonary nodules account for 30 to 40 percent of all solitary pulmonary nodules (SPNs). Therefore, characterization of SPNs is very important for treatment. Recently, dynamic CT has been widely used for tissue characterization and formation of differential diagnoses. The purpose of this study was to evaluate the ability of dynamic CT to formulate the differential diagnosis of SPNs. Materials and Methods : Nineteen patients with SPNs underwent dynamic CT (unenhanced scans, followed by a series of images at 20, 40, 60, 80, 100, 120, 140, 160, and 180 sec after intravenous injection of contrast medium). Diagnosis of SPN was performed based on pathologic findings in needle biopsy samples. Peak enhancement, net enhancement, slope of enhancement, and maximum relative enhancement ratio of the SPN were measured on dynamic CT, and Levene's test was performed to assess benignancy and malignancy. Results : Twelve SPNs were confirmed to have malignant pathology. There were no significant differences between benign and malignant nodules with respect to peak enhancement (p=0.787), net enhancement (p=0.135), or slope of enhancement (p=0.698). The maximal enhancement ratio was increased in malignancy compared to benignancy, but the difference was not statistically significant (p=0.094). Conclusion : In our study, the hemodynamic characteristics of dynamic CT were not significantly different between benign and malignant nodules. Therefore, long-term studies of larger patient samples are required to confirm our findings.

  • PDF

Cardiac MRI (심장 자기공명영상)

  • Lee, Jong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The obstacles for cardiac imaging are motion artifacts due to cardiac motion, respiration, and blood flow, and low signal due to small tissue volume of heart. To overcome these obstacles, fast imaging technique with ECG gating is utilized. Cardiac exam using MRI comprises of morphology, ventricular function, myocardial perfusion, metabolism, and coronary artery morphology. During cardiac morphology evaluation, double and triple inversion recovery techniques are used to depict myocardial fluidity and soft tissue structure such as fat tissue, respectively. By checking the first-pass enhancement of myocardium using contrast-enhanced fast gradient echo technique, myocardial blood flow can be evaluated. In addition, delayed imaging in 10 - 15 minutes can inform myocardial destruction such as chronic myocardial infarction. Ventricular function including regional and global wall motion can be checked by fast gradient echo cine imaging in quantitative way. MRI is acknowledged to be practical for integrated cardiac evaluation technique except coronary angiography. Especially delay imaging is the greatest merit of MRI in myocardial viability evaluation.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Digital Subtraction Angiography

  • Ko, Seong-Jin
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.21-26
    • /
    • 1983
  • DSA는 해상능(解像能)에 있어서는 일반적(一船的)인 혈관(血管) 조영술(造影術)에 비해서 다소 못미치지만 소량(小量)의 조영제(造影劑)로도 혈관구조(血管構造)를 잘 관찰(觀察)할 수 있으며 큰 차이의 조직(組織)두께차를 적절히 수용(受容)할 수 있으며 필름의 소모도 적게 되었다. DSA는 경동맥검사(頸動脈檢査)에 가장 중요한 위치를 차지하며 많이 시행(施行)되고 있다. 혈관(血管)의 모양을 변화(變化) 시키는 여러 질환에서 혈관(血管)상태나 혈류(血流)의 변화(變化), 내경(內經)도 알수 있다. 최근에는 흉부(胸部)나 후두(喉頭) 등(等)에도 적용하여 일반검사(一般檢査)와 비교(比較)하여 좋은 결과(結果)를 얻고있다. 또 확대촬영(擴大撮影)이나 입체촬영(立體撮影)까지 응용(應用)하여 좋은 성적을 얻고 있다. DSA는 보고자 하는 혈관상(血管像)만을 단시간에 볼 수 있고 유연성(柔軟性)이 있고 비침습성(非侵襲性)(noninvasive)이며 간단한 검사방법(檢査方法)이라는 점 등(等)에서 매우 유용(有用)한 검사(檢査)라 하겠다.

  • PDF