• Title/Summary/Keyword: 조영

Search Result 9,136, Processing Time 0.034 seconds

Determination of Early Graft Patency Using CT Angiography after Coronary Artery Bypass Surgery (관상동맥우회술 후 CT 조영술을 이용한 이식편의 조기 열림의 판정)

  • 이미경;류대웅;최순호;최종범
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.570-577
    • /
    • 2004
  • CT angiography is now available to evaluate the early graft patency after coronary bypass surgery. We investigated whether patency or occlusion of the bypass grafts can be visualized by CT angiography and what factors effect the visuality. Material and Method: Fifty patients underwent scanning with a 4-slice computed tomographic scanner (Somatom Volume ZoomTM; Siemens, Germany) before being discharged after coronary artery bypass grafting. To evaluate graft patency and relationship between the quality of graft image and the characteristics of the diseased coronary vessels, 50 internal thoracic artery grafts, 18 radial artery grafts, and 56 vein grafts were included in this study. Result: All vein grafts (24 grafts; 32 anastomoses) to left coronary artery system were well visualized, but 3 grafts (4.7%) of 30 vein grafts (35 anastomoses) to right coronary artery system were not visualized. The latter was also occluded in invasive coronary angiographic study. Thirty-nine (78%) internal thoracic artery grafts were well visualized, 8 (16%) faintly visualized, and 3 (6%) not visualized, but all the internal artery grafts were well patent in invasive coronary angiographic study. Conclusion: Unvisualized vein grafts in CT angiography means occlusion of the grafts, but unvisualized arterial grafts in CT angiography may not mean occlusion of the graft but result from competitive flow between the graft and coronary artery. To confirm patency of the unvisualized arterial grafts, invasive coronary angiography is needed.

Synthesis of contrast CT image using deep learning network (딥러닝 네트워크를 이용한 조영증강 CT 영상 생성)

  • Woo, Sang-Keun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.01a
    • /
    • pp.465-467
    • /
    • 2019
  • 본 논문에서는 영상생성이 가능한 딥러닝 네트워크를 이용하여 조영증강 CT 영상을 획득하는 연구를 수행하였다. CT는 고해상도 영상을 바탕으로 환자의 질병 및 암 세포 진단에 사용되는 의료영상 기법 중 하나이다. 특히, 조영제를 투여한 다음 CT 영상을 획득되는 영상을 조영증강 CT 영상이라 한다. 조영증강된 CT 영상은 물질의 구성 성분의 영상대비를 강조하여 임상의로 하여금 진단 및 치료반응 평가의 정확성을 향상시켜준다. 하지많은 수의 환자들이 조영제 부작용을 갖기 때문에 이에 해당되는 환자의 경우 조영증강 CT 영상 획득이 불가능해진다. 따라서 본 연구에서는 조영증강 영상을 얻지 못하는 환자 및 일반 환자의 불필요한 방사선의 노출을 최소화 하기 위하여 영상생성 딥러닝 기법을 이용하여 CT 영상에서 조영증강 CT 영상을 생성하는 연구를 진행하였다. 영상생성 딥러닝 네트워크는 generative adversarial network (GAN) 모델을 사용하였다. 연구결과 아무런 전처리도 거치지 않은 CT 영상을 이용하여 영상을 생성하는 것 보다 히스토그램 균일화 과정을 거친 영상이 더 좋은 결과를 나타냈으며 생성영상이 기존의 실제 영상과 영상의 구조적 유사도가 높음을 확인할 수 있다. 본 연구결과 딥러닝 영상생성 모델을 이용하여 조영증강 CT 영상을 생성할 수 있었으며, 이를 통하여 환자의 불필요한 방사선 피폭을 최소하며, 생성된 조영증강 CT 영상을 바탕으로 정확한 진단 및 치료반응 평가에 기여할 수 있을거라 기대된다.

  • PDF

The Frontiers of Product Liability for Adverse Reactions to the Contrast Medium (조영제부작용에 대한 제조물책임의 한계)

  • Lim, Chang-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1386-1391
    • /
    • 2008
  • The Korean Product Liability Act established the principle that a manufacturer has a duty to take care of a person who is not the customer who bought the product for him. In this instance, there is a duty to the patient for whom the product was purchased by the hospital from the pharmaceutical company. Therefore, the pharmaceutical company has the product liability for adverse reactions to the contrast medium. But the possibility for the patient to successfully sue the pharmaceutical company is quite low, because the patient needs to prove that a "defect" in the unsafe product was the cause of his injuries. And the physician or the radiological technologist can not reduce his liability risks based on the Product Liability Act. On the contrary, The has the product liability because diluting contrast medium belongs to the product category.

Usefulness of Reverse Flow Prevention Valves for Back-flow Prevention of Gadolinium Based Contrast Agent in Dynamic Examination of Magnetic Resonance Imaging (자기공명영상 동적검사 시 조영제 역류방지용 밸브의 유용성)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.6
    • /
    • pp.439-444
    • /
    • 2020
  • The purpose of this study is to seek an alternative method to prevent the contamination of normal saline caused by the back-flow of Gadolinium Based Contrast Agent(GBCA) by the use of auto-injector for dynamic MRI. The research method is to manufacture the non-return valve as an alternative to the existing, and to examine the usefulness of the normal saline by dividing the state of normal saline into three groups. The signal intensity were compared. As a result, there was no statistically significant difference between normal saline before injection of group 1 and group 3 non-return valve (p> 0.05). It is analyzed that the self-produced non-return valve completely blocked the GBCA back to normal saline when the GBCA was injected. In conclusion, the application of the non-return valve presented in this study for dynamic MRI imaging using the auto injector can prevent normal saline contamination due to GBCA back-flow.

삼차원 조영증강 자기공명혈관조영술을 이용한 내경동맥 협착에 대한 평가: 디지털감산혈관조영술과의 비교

  • 한동복;최충곤;박지강;이정현;이호규
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.139-139
    • /
    • 2001
  • 목적: 경동맥 분지부에서 내경동맥 협착에 대한 평가에 있어서 삼차원 조영증강 자기공명혈관조영술의 정확도를 알아보고자 하였다. 대상 및 방법: 삼차원 조영증강 자기공명혈관조영술(3D Contrast-enhanced MRA)과 디지털감산혈관 조영술(Digital Subtraction Angiography, DSA)을 모두 시행한 35명의 환자, 68예의 내경동맥을 분석하였다. 내경동맥 협착의 측정은 North American Symptomatic Carotid Endarterectom Trial (NASCET) 기준을 이용하였다. 두 가지 검사에서 협착 정도를 경도(mild:0-29%), 중등도(moderate:30-69%), 심한 협착(severe:70-99%), 완전 폐색(occlusion:100%)등 네 그룹으로 나누었다. 두 명의 관찰자(A,B)가 DSA에서 측정한 협착 정도를 기준으로 3D Contrast-enhanced MRA에서 측정한 협착 정도를 비교하여 두 검사 방법간에 판정 일치율과 차이점을 분석하였다.

  • PDF

The Precaution Duty and the Product Liability for Adverse Reactions to the Contrast Media (조영제 부작용에 대한 주의의무와 제조물책임)

  • Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.305-311
    • /
    • 2007
  • Contrast medium is a useful drug for radiological examinations and usability of it gradually increases while it has some inevitable adverse reaction and it is difficult to predict the occurrence and the degree of adverse reactions. Although the patient consented permission for the use of contrast media, the hospital could not be exempted from the responsibility for the adverse contrast media reaction. During radiological contrast media examination, the radiologist and the contrast media producer have the duty of precaution, prediction and avoid adverse results. In addition, they have reliabi lity of patient remedy for neglecting the duty. Since contrast medium are manufactured or processed as movable properties, the manufacturers are bound to the product liability if damages occur due to the defects in pharmaceuticals. In consideration of the characteristics of product liability, it is necessary to demand high degree of duty of care and diligence from producer or to reduce patient's burden of proof in a product liability lawsuit. For securing compensation ability and liability implementation, products compensation liability insurance is required for contrast medium manufacturers. In conclusion, contrast medium producer has legal liability for adverse reactions and the contract concluded with producer and hospital including legal liability will reduce liability of hospital and radiologist, patient.

  • PDF

Changing mask timing reduces venous contamination in contrast enhanced MR Angiography of the head and neck (조영제 사용 후 혈관조영영상 획득 시, mask 영상의 획득 시점에 따른 정맥 신호의 감소)

  • Lee, ho-beom;Chung, mi-ae
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.385-386
    • /
    • 2017
  • 진단을 위해 조영제를 연속해서 사용하는 검사는, 첫 번째 주입으로 인해 조영제가 영상에 미치는 효과를 고려해야 한다. 본 연구에서는 mask 영상의 획득 시점을 통해 이를 개선하고자, 관류영상 획득 후 조영영상을 감산하는 새로운 방법을 제시하여, 혈관 겹침의 원인이 정맥의 신호강도를 유의하게 감소시켰다. 따라서, 본 연구의 방법을 이용하면, 복잡한 재구성이나 추가적인 기법 없이도, 효율적으로 정맥신호를 제거 할 수 있어 유용하리라 사료된다.

  • PDF

Research and Consideration of Eco-friendly Radiation Shielding using CT Contrast Agent (CT 조영제를 이용한 친환경적인 방사선 차폐에 관한 연구 및 고찰)

  • Sung-Gil Kim;Yeon-Sang Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.827-833
    • /
    • 2023
  • CT(Computed Tomography) contrast agents are commonly used in general hospitals and university hospitals when taking radiographic examinations. The CT contrast medium contains a mixture of a substance called "Iodine", which absorbs radiation energy and makes it appear white in the CT image, further improving the image quality. In addition, the CT contrast agent, which moves like blood in the blood vessels, clearly differentiates it from muscle and water, so CT contrast agents are widely used in hospitals. These CT contrast agents absorb X-rays, but in order to absorb X-rays, they must have a high density or a high radiation absorption coefficient. Since the CT contrast agent is injected into the blood vessels, if the density is high, the blood vessels are strained and the patient is in shock. For this reason, it is necessary to match the density similar to that of water and always pay attention to side effects. In addition, the amount of CT contrast medium is adjusted according to the patient's body shape, and the remaining contrast medium is discarded. However, This study tried to find out the idea of recycling it as a radiation shielding material. Since the CT contrast medium has a high radiation absorption coefficient at a density similar to that of water, the amount to absorb radiation is adjusted, the amount of contrast medium and the amount of water are adjusted, and the amount of radiation absorbed is determined by mixing with water. In addition, a study was conducted to find out the result of the difference in radiation absorption in various ways by comparing the radiation quality coefficient and absorption coefficient with other substances or materials in an environmentally friendly method harmless to the human body by mixing CT contrast medium and water.

Dynamic MR Imaging in Gastric Cancer : Comparison Between Precontrast and Postcontrast Images (위암의 역동적 자기공명영상: 조영증강 전 후 영상의 비교)

  • 홍성환;한준구;장기현;최병인
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.130-134
    • /
    • 1997
  • Purpose: To analyze contrast-enhancement pattern of stomach cancer on dynamic MRI and to verify the efficacy of intravenous contrast agent in the evaluation of stomach cancer. Materials and Methods: Twelve patients with proven stomach cancer underwent dynamic MRI. By using l.OT scanner, we obtained precontrast FLASH images, and 30, 60, 90 second delay FLASH images after intravenous contrast injection. All patients ingested one liter of water and had intramuscular injection of Buscopan just before MR study. For quantitative analysis we measured signal to noise ratio (SiN) of stomach cancer on each image, and signal difference to noise ratio (SD/N) between cancer and intraluminal fluid, cancer and the pancreas. For qualitative analysis two radiologists evaluated lesion conspicuity on each image by grading system(grade 0, 1, 2, 3: poor, fair, good, excellent). Results: SiN of stomach cancer increased gradually by time(precontrast, 30, 60, 90 second delay: 38.7, 42.5, 57.4, 65.7). SD/N between cancer and intraluminal fluid significantly increased after contrast enhancement(l.24, 25.01, 39.30, 45.89). SD/Ns between cancer and the pancreas were 10.5, 9.33, 9.99, 10.66, respectively. In qualitative analysis, precontrast images were better than postcontrast images for delineation of stomach cancer. Postcontrast images showed clear endo-Iuminal side of stomach cancer, but outer margin of stomach cancer was more distinct on precontrast images. Conclusion: Precontrast MR images are better than postcontrast MR images in the depiction of stomach cancer. Intravenous contrast agent is not imperative in the evaluation of stomach cancer.

  • PDF

Contrast Optimization using of Weight-based Injection Protocol in Pediatric Abdomen CT Examination (소아 복부 CT 검사에서 체중에 기반한 조영제 주입 프로토콜 적용에 따른 조영증강의 최적화)

  • Kim, Yung-Kyoon;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.575-584
    • /
    • 2021
  • The aim of this study was to achieve optimal portal phase while reducing contrast medium by applying weight-based dose protocol compared to standard fixed dose protocol to performing of pediatric abdominal CT examination. Discovery 750HD (General Electric Medical Systems, Milwaukee, USA) was used, and a total of 167 children consisting of 85 men and 82 women under the age of 18 were studied. The group in which the 300 mgI/ml(Xenetix, Guerbet, France) contrast medium was fixedly injected at twice body weight and the group injected with physiological saline while gradually decreasing the injection amount by 10% while applying the weight-based protocol were distinguished. Also, the CT number and SNR of abdominal organs were compared and evaluated while changing the scan delay time. Subjective image quality of enhancement and beam-hardening artifacts of around the heart was assessed with five-point criterion. The group adapted weight-based protocol with 20% reduction in contrast medium was most similar in contrast enhancement in the group with fixed injection at twice body weight. Furthermore, the group with a delay time of 20% had the highest contrast enhancement effect, and the difference in CT attenuation coefficient from the group scanned immediately after injection of the contrast media. Therefore, the appropriate delay time after injection of the contrast agent increased the contrast enhancement of the parenchymal organ. In addition, the weight-based injection protocol with normal saline reduced artifacts around the heart, and the effect of contrast enhancement could be maintained. In conclusion, it is possible to reduce dosage of contrast media through the application of weight-based injection protocols and appropriate latency, and to characterize optimal portal phase imaging on pediatric abdominal CT.