• Title/Summary/Keyword: 조명부하

Search Result 439, Processing Time 0.021 seconds

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting (조명발열 배기시스템의 배기위치에 따른 배기열량 실험연구)

  • Oh, Byung-Kil;Chung, Min-Ho;Won, Jong-Seo;Lee, Hun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • This study aims to reduce cooling energy by grasping kinds of heating load in building in order to decrease cooling energy in summer and eliminate efficiently heating load. Lighting heating value was confirmed through examination and experiment concerning lighting heating and reducible exhaustion value was extracted lighting apparatus. The optimal exhaust system by air conditioning type was suggested for applying lighting heat exhaust system and the method contributing to promotion supplying low energy architecture was suggested by predicting reduced cooling load.

Study on Development of Light Duct System for Perimeter Occupied Zone on Underground Space (지하대공간에 있어 Perimeter Occupied Zone에 대한 채광덕트 시스템 개발에 관한 연구)

  • 김회서;이성주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.21-26
    • /
    • 1999
  • Using daylight in underground spoce may significantly reduce electric lighting load and give a visually comfortable environment. This reper describes a fundaIrentaI study on light duct system to predict inter illuminance ratio on underground periIreter occupied zone level. As a result, integral equation for inter-reflection program are developed and by using optimize light duct system can gives daylight on deep underground space. space.

  • PDF

Daily peak load forecasting considering the load trend and temperature (수요경향과 온도를 고려한 1일 최대전력 수요예측)

  • 최낙훈;손광명;이태기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.6
    • /
    • pp.35-42
    • /
    • 2001
  • Since daily peak load forecasted data are essential to economic operation and power monitor, the technique of accurate forecasting is needled. The chief advantage of forecasting technique using neural network and fuzzy theory is high accuracy and operative implicity but the loaming time is long, and it makes large forecasting error when the load changes rapidly. This paper has resented a new forecasting technique to improve those faults and the forecasting technique prove to be valid by forcasted results.

  • PDF

Operational Characteristics of DC Reactor Type SFCL for Accident of Both Power Source Side and Load Side (전원단 및 부하단 사고에 따른 DC 리액터형 고온초전도 전류제한기 동작특성)

  • Lee, Su-Won;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.140-145
    • /
    • 2004
  • In this paper, we analyzed the operational characteristics of the modified DC reactor type SFCL and derived the design condition of superconducting coil to be operated properly as power source as well as fault current limiter. It was confirmed through the simulation for the operation of this SFCL that the modified DC reactor type SFCL could be operated as both the uninterruptible power supply and the fault current limiter by controlling the duty ratio of GTO thyristor bridge.

Performance Evaluation and Support of Failure Analysis for 25.8kV $SF_6$ Gas Insulated Load Breaker Switchgear (25.8kV $SF_6$ 가스절연 부하개폐기의 고장분석 및 성능평가)

  • Kim, Dong-Myeong;Chun, Sung-Nam;Kwon, Tae-Ho;Choi, Sun-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.244-247
    • /
    • 2005
  • 본 논문은 최근 2년간 25.8kV 가스 절연 부하개폐기에서 발생한 고장을 전력연구원에서 분석하여 고장 원인별 현황을 나타내었다. 고장 주요원인인 절연불량, 기계적 손상, 외부 손상 등이 발생하는 원인을 분석하였다. 가스절연개폐기의 고장모드 및 성능평가 방법을 나타내었다. 개폐기의 장기신뢰성 확보를 위해서는 제조업체 및 한전의 품질개선을 위한 노력이 필요하며 특히, 경년특성을 검증할 수 있는 효율적인 방법의 제시가 필요하다.

  • PDF

Analysis of Condenser Thermal Distribution by the Variance of Voltage & Frequency (전압 및 주파수 변동에 따른 콘덴서 열 분포 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.33-36
    • /
    • 2009
  • 콘덴서는 유도성 부하의 늦은 역률 보상으로도 사용되며, 비선형 부하에서 발생하는 고조파를 저감하기 위해 리액터에 직렬로 연결하여 사용되기도 한다. 콘덴서는 전압이 증가할 경우 전류도 함께 증가하고, 주파수가 증가할 경우 콘덴서에 흐르는 전류가 증가하기 때문에 전류의 증가는 바로 열의 증가로 콘덴서 절연에 스트레스로 작용하여 고장의 원인을 제공할 수 있다. 본 연구에서는 콘덴서에 인가되는 전압의 크기와 주파수를 변화시킬 경우 콘덴서에서 발생하는 열을 열화상 카메라로 측정하여 외부 및 내부에서의 온도분포를 분석하였다. 측정결과 전압과 주파수가 증가할 경우 콘덴서에서 열이 매우 높게 분포함을 확인할 수 있었다.

  • PDF

The Speed Controller of DC Motor Using Model Reference Adaptive Control Method (기준 모델 적응 제어 방직을 이용한 직류 전동기의 속도 제어기)

  • 이성백;원영진;한완옥;임현철
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.41-46
    • /
    • 1992
  • 고전적인 제어 기법들을 이용한 전동기의 속도 제어기는 하나의 고정된 동작점에 대해서 대개 양호한 동작 특성을 얻을 수 있으나 전동기 매개변수의 섭동 및 부하 외란의 존재시 규정된 제어 동작을 유지하기가 어렵다는 단점을 갖고 있다. 따라서 본 연구에서는 이러한 단점을 극복하기 위하여 적응 제어 기법중의 하나인 기준 모델 적응 제어 (Model Reference Adaptive Control : MRAC) 방식을 직류 전동기의 속도 제어에 적용하였으며 또한, 2차 이상인 전동기의 속도 제어 시스템을 1차로 저차화시켜 제어 알고리즘의 계산에 소요되는 시간을 줄임으로써 실시간 제어가 가능토록 하였다. 제시된 기준 모델 제어 기법과 PI 제어 기법을 직류 전동기의 속도 제어에 각각 적용하고 부하의 관성변화에 다른 속도 응답 특성을 실험을 통하여 비교 검토하였다.

  • PDF

Speed Control of Induction Motor by Means of Expert PLC in Variable load (가변부하시 전문가 PLC에 의한 유도전동기의 속도제어)

  • Park, Wal-Seo;Oh, Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.54-58
    • /
    • 2002
  • PID Controller is widely used as automatic equipment for industry. However, when a system has various characters, parameter decision and tuning for accurate control is a hard task. In this paper, expert auto-tuning PID controller using PLC is presented as away of solving this problem. Expert auto tuning algorithm is based on Ziegler-Nichols step response and expert knowledge. The test of control performance is carried out in practical speed control of Induction Motor in variable load, the experimental results suggest its superior performance.

Power Converter for LED Drive with Minimized Cost (조명용 LED 구동을 위한 최소원가의 전력변환기)

  • Park, H.Y.;Jung, J.H.;Nho, E.C.;Kim, I.D.;Kim, H.G.;Chun, T.W.
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.135-136
    • /
    • 2013
  • 본 논문에서는 조명용 LED 구동을 위한 최소원가형 전력변환장치를 제안하였다. 부하측의 전압과 전류 피크값을 낮춤으로써 스위칭 손실을 줄이면서 플리커 현상도 최소화하고, 입력전압과 전류를 동상에 가깝게 제어를 하여 역률을 최적화 하였다. 전해커패시터를 없앰으로써 장수명화에 기여를 하였고, 필터에 사용되는 소량의 용량은 필름커패시터를 대체하여 부하측 전류의 안정화에 기여하였다. 본 연구의 결과는 LED 구동용 전원장치의 최적화에 기여하여 장수명화 및 비용을 최소화할 것으로 기대된다.

  • PDF