• Title/Summary/Keyword: 조명기구

Search Result 316, Processing Time 0.025 seconds

Optimization and Fabrication of Color Temperature Tunable White LED Luminaires (색온도 가변 LED 조명 최적화 설계 및 제작)

  • Kang, Da-Il;Kim, Kun-Yul;Yu, Young-Moon;Choi, Hee-Lack
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.102-107
    • /
    • 2014
  • In this paper the spectra of correlated color temperature (CCT) tunable white light-emitting diode (LED) luminaires, consisting of commercial red, green, blue, and amber LED chips, were optimized to increase color rendering index (CRI), and a special CRI of R9 for deep red color was obtained. To improve the design's accuracy, measured LED spectra were used instead of mathematically modeled ones. Real CCT tunable LED luminaires with CRIs of 87-90 and R9s of 34-93 were fabricated and demonstrated at CCTs of 3000-6000 K.

Evaluation of Interior Factors in Gyunro-dang and Recommendations for Improvement -In 14 Facilities at Apartment Complex in Seoul- (경로당 실내환경 평가와 개선방안 -서울지역 아파트 단지 내 14개 시설을 중심으로-)

  • 천진희
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.353-362
    • /
    • 2004
  • This research has been done to evaluate the interior environmental factors in Gyungro-dang to suggest the advanced recommendations for them. For this research, the essential interior elements influencing on elderly's behavior were examined with the developed checklist, the lighting and color conditions of main hall at 14 facilities in Seoul area were analysed, and 124 subjects staying at Gyungro-dang were participated in questionaire survey for color preferences. Results showed that 1.The average installation rate of 39 items in checklist was 59%, the mandatory items such as accessible dimension were considered, but several items related to mobility and safety were not properly installed. Therefore not only guiding handrail and floor block to destination but also elimination of obstacles should be reconsidered. 2.The average of illuminances was 289 Lux dose to standard 300 Lux, but lighting quality was too low to support the activities of elderly users. The lighting control devices, combined lighting sources, and suitable lighting techniques should be applied for those facilities. 3.Most facilities were predominantly in warm colors in hue, medium or high value, low saturation, and natural atmosphere with similarity harmony. The color applications in those facilities were not functional, but similar as color preferences for the elderly except overall atmosphere. It is recommendable to include contrast harmony with classic or romantic mood.

  • PDF

Analysis of Frictional Characteristics of Direct-Acting OHC Valve Train System Equipped with HLA (HLA를 장착한 직접 구동형 OHC 밸브 트레인 시스템의 마찰 특성 해석)

  • 지유철;조명래;한동철;최재권
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.3
    • /
    • pp.78-87
    • /
    • 1998
  • A dynamic model of direct-acting OHC valve train system has been used to determine the load conditions in the system. The modified equations for calculating the friction forces between cam and HLA, and at a camshaft bearing have been defined considering the lubrication conditions. Then, to understand the frictional characteristics in the system, a parameter study has been performed. As the results of the analysis, valve spring stiffness and preload have great effects on the friction in the system, but the effects of other parameters are negligible. So, how to design the valve train system with respect to the reduction of friction is to minimize the valve spring stiffness and preload in the limit of satisfying the dynamic constraints.

  • PDF

Analyze on Heat-sink of 20Watt Class LED Lamp using COMSOL (COMSOL을 이용한 20W급 LED램프의 방열 해석)

  • Eo, Ik-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1484-1488
    • /
    • 2009
  • This thesis is about Heat-sink design which is considered as the biggest problems for commercialization of LED lighting and suggests how to solve the problems though analysis on heat-sink using COMSOL. The temperature difference after simulation value and modelling was $10^{\circ}C$by Transient analysis of Heat Transfer Module which is in the COMSOL Multiphysics. The result approximated the object which is close to actual lighting, when various elements are used according to temperature change of interior and exterior surroundings LED lighting is set up.

A Study on Walking Characteristics of Novices at Onboard Environments under Blackout Conditions in a Training Ship (선내 정전조건에서 승선환경 비숙련자의 이동특성 실험 연구)

  • Hwang, Kwang-Il;Cho, Ik-Soon;Lee, Yun-Sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.74-81
    • /
    • 2016
  • Because most of the passengers are not accustomed with onboard environments, it is very important to analyze and predict the behaviors' characteristics of passengers under disasters' conditions, and apply those results for making countermeasures. On this view point, this study focused on the walking characteristics of onboard-novices are tested and analyzed under blackout condition that has high possibility to happen. As a result, comparing to under normal lighting conditions, the waking times under blackout conditions are 155.8~247.1 % longer on full path, 56.9~331.7 % on corridors, 75.3~152.9 % on stairs, respectively. And under the same blackout conditions, walking times in cases of the exit guidance marks being attached on top side of walls saved times, like 21.6~24.0 % on full path, 37.7~58.9 % on corridors, 18.7~19.2 % on stairs, comparing to the cases of exit guidance marks being not attached. On the other hand, after tests under without exit guidance marks, 60.7% among respondents answered that internal structures like wall/stair (35.7 %) and handrail (25 %) are very helpful to decide way findings, and 28.6 % selected personal instincts is important. But 50 % responded that exit guide marks are effective to find ways, after the tests under with exit guidance marks.

Mechanism of Micro-V Grooving with Single Crystal Diamond Tool (단결정 다이어몬드 공구를 이용한 Micro-V 홈 가공기구)

  • Park D.S.;Seo T.I.;Kim J.K.;Seong E.J.;Han J.Y.;Lee E.S.;Cho M.W.;Choi D.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1223-1227
    • /
    • 2005
  • Fine microgroove is the key component to fabricate micro-grating, micro-grating lens and so on. Conventional groove fabrication methods such as etching and lithography have some problems in efficiency and surface integrity. This study deals with the creation of ultra-precision micro grooves using non-rotational diamond tool and CNC machining center. The shaping type machining method proposed in the study allows to produce V-shaped grooves of $40\mu{m}$ in depth with enough dimensional accuracy and surface. For the analysis of machining characteristics in micro V-grooving, three components of cutting forces and AE signal are measured and processed. Experimental results showed that large amplitude of cutting forces and AE appeared at the beginning of every cutting path, and cutting forces had a linear relation with the cross-sectional area of uncut chip thickness. From the results of this study, proposed micro V-grooving technique could be successfully applied to forming the precise optical parts like prism patterns on light guide panel of TFT-LCD.

  • PDF

Thermal Analysis of a Radial Heat Sink with Radiation and Natural Convection (복사 열전달을 고려한 자연대류 원형 히트싱크 열전달 해석)

  • Yu, Seung-Hwan;Jang, Dae-Seok;Lee, Kwan-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.4
    • /
    • pp.385-390
    • /
    • 2012
  • A radial heat sink, adopted to LED(light emitting diode) downlight, was optimized. Discrete transfer radiation model (DTRM) was used to calculate radiation heat transfer, and numerical model was verified with experimental results. The effects of number of fin, long fin length and middle fin length on overall thermal resistance and radiation heat transfer were analyzed. As the emissivity increased, thermal resistance decreased due to the increment of radiation heat transfer. The radial heat sink was optimized and optimum number of long fins is 19~28, optimum length of long fin is about half of radius of heat fink and optimum fin ratio is 0.4~0.7.

Development of Deterioration Diagnosis System for Aged ACSR-OC Conductors in HV Overhead Distribution Lines (고압 가공배전선의 노화된 ACSR-OC 도체에 대한 열화진단시스템 개발)

  • 김성덕;이승호
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.43-50
    • /
    • 2000
  • Design and experiments of a nondestructive testing system with a solenoid eddy current sensor to inspect deterioration of ASCR-OC (ACSR Outdoor Cross-linked Polyethylene Insulated Wires) usually used in HV overhead distribution lines in domestic areas in presented in this paper. Through corrosion mechanisms and deterioration results for ACSR-OC conductors are examined, it is shown that corrosion may lead to the reduction of the effective cross section area of conductors is proposed. The measurement system consisting of a constant current source with a RF frequency, a signal processing unit and a motor driver/ controller is designed and implemented. This instrument has such capabilities as detecting the sensor output and estimating diameter change of the testing conductors, continuously. As a result, it was verified that such corrosion detector system with an eddy current sensor can be shown good effectiveness for estimating the serious faults due to deterioration in overhead distribution lines and giving an early warming before severe aged conductor may lead to fail.

  • PDF

Temperature Rise and Dielectric Characteristics of Distribution Transformers with Over-Loading Operation (배전용변압기의 부하운전에 의한 온도 및 유전특성 분석)

  • Kim, Byung-Sook;Lee, Byung-Sung;Song, Il-Keun;Han, Byoung-Sung;Joung, Jong-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.104-110
    • /
    • 2007
  • Temperature rise characteristics of medium voltage class transformers and dielectric characteristics of its insulation oil according to the loading rate were investigated using the transformer that has thermocouples embedded in the windings. The hottest-spot of the transformer locates at about 2/3 height of the windings where they adjoin each other among the 3 phase windings. The temperature difference between the hottest-spot and top-oil is about $17[^{\circ}C]$ and the value keeps uniformly in short time after changing the loading rate. Capacitance of the oil varies in inverse proportion to temperature and the inclination rate is about -0.0106 that is not dependent on the aging rate. On the other hand the capacitance is increased depending on the aging rate, so the capacitance characteristics of the oil could be applied to the diagnostic technique.

Design and Dose Distribution of Docking Applicator for an Intraoperative Radiation Therapy (수술중 방사선치료를 위한 조립형 조사기구의 제작과 선량 분포)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, John-Kyu
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.123-130
    • /
    • 1991
  • A docking intraoperative electron beam applicator system, which is easily docking in the collimator for a linear accelerator after setting a sterilized transparent cone on the tumor bearing area in the operation room, has been designed to optimize dose distribution and to improve the efficiency of radiation treatment method with linear accelerator. This applicator system consisted of collimator holder with shielded metals and docking cone with transparent acrylic cylinder, A number of technical innovations have been used in the design of this system, this dooking cone gives a improving latral dose coverage at therapeutic volume. The position of $90\%$ isodose curve under suface of 8 cm diameter cone was extended $4\sim7$ mm at 12 MeV electron and the isodose measurements beneath the cone wall showed hot spots as great as $106\%$ for acrylic cone. The leakage radiation dose to tissues outside the cone wall was reduced as $3\sim5\%$ of output dose. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented.

  • PDF