• Title/Summary/Keyword: 조립오차

Search Result 126, Processing Time 0.026 seconds

A Study of Spacecraft Alignment Measurement with Theodolite (데오도라이트를 이용한 위성체 얼라인먼트 측정에 관한 연구)

  • Yun,Yong-Sik;Park,Hong-Cheol;Son,Yeong-Seon;Choe,Jong-Yeon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.10
    • /
    • pp.105-111
    • /
    • 2003
  • A measurement of spacecraft alignment is an important process of spacecraft assembly, integration and test. Because, it is necessary that a operator of a ground station controls the precise positions of on-orbit spacecraft by using the alignment data of attitude orbit control sensors(AOCS) on spacecraft. And, an accuracy of spacecraft alignment requirement is about $0.1^{\circ}{\sim}0.7^{\circ}$. A spacecraft alignment is measured by autocollimation of theodolite. This paper describes the measurement principle and method of spacecraft alignment. The result shows that all the AOCS on the spacecraft are aligned within the tolerance required through the alignment measurement.

A study on the improvement of construction error in PM stepping motor with claw pole (Claw pole PM stepping motor의 조립 오차를 개선시키기 위한 연구)

  • Ham, Sang-Hwan;Lee, Sung-Gu;Go, Sung-Chul;Kim, Won-Ho;Lee, Hyung-Woo;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1005-1006
    • /
    • 2007
  • This paper analyzed the characteristics of the claw pole permanent magnet(PM) stepping motor by using 3D Finite element method(FEM). In this motor, magnetization is occurred along the z-axis, therefore it is necessary to apply 3D FEM for analysis of the claw pole motor. A phase difference of the two stacks's detent torque is 180 degrees. When the center of a permanent magnet is identical with the middle of a pole, small detent torque is produced in order to cancel each of detent torques. However, there are construction errors which are a discrepancy between one and the other phase section in the manufacturing process, thus the detent torque is increased. Moreover, it is confirmed that the proportion of the detent torque is considerably arisen according to the error. Analysis of the construction error is studied by changing the error $0^{\circ}$ to $3^{\circ}$.

  • PDF

A Study on the Evaluation of the Optical Head of a Near-field Optical Recording System and Interference Pattern Analysis (근접장 광기록 헤드의 광학적 성능 평가와 정렬 오차에 대한 간섭 무늬 패턴 분석에 대한 연구)

  • Yoon Hyoung Kil;Gweon Dae Gab;Lee Jun Hee;Jung Jae Hwa;Oh Hyung Ryeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.5 s.170
    • /
    • pp.80-86
    • /
    • 2005
  • Optical performance evaluation results and an interference fringe pattern analysis of alignment errors for an optical head of a near-field receding (NFR) system are presented. The focusing unit is an optical head of a NFR system and is composed of a solid immersion lens (SIL) and an objective lens (OL). Generally, the size of the focusing unit is smaller than that of the conventional optical recording head. Hence there are difficulties to assemble the small focusing unit precisely. We composed an evaluation system with an interferometer and evaluated some focusing unit samples aligned and assembled by manual and present the obtained results. Using the conventional optical tool, Code V, a tolerance analysis of the alignment error between the SIL and the objective lens and an interference pattern analysis for the assembly error are executed. Then, through an analysis of the simulation results, the conceptual auto-alignment methodology using a neural network approach is considered.

Study on the Dynamic Behavior Characteristics due to the Unbalance High Speed Railway Vehicle Wheel (고속철도차량용 차륜 불평형에 의한 동적 거동 특성 연구)

  • Lee, Seung-Yil;Song, Moon-Shuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.175-181
    • /
    • 2016
  • This occurs when the unbalanced rotating body is inconsistent with the mass center line axis geometric center line. Wheelsets are assembled by a single axle with two wheels and a rotating body of a running railway vehicle. Owing to non-uniformity of the wheel material, the wear, and error of the wheel and axle assembly may cause an imbalance. Wheelsets will suffer the effects of vibrations due to the unbalanced mass, which becomes more pronounced due to the thin and high-speed rotation compared to the shaft diameter This can affect the driving safety and the running behavior of a rail car during high-speed running. Therefore, this study examined this unbalanced wheel using a railway vehicle multibody dynamics analysis tool to assess the impact of the dynamic VI-Rail movement of high-speed railway vehicles. Increasing the extent of wheel imbalance on the analysis confirmed that the critical speed of a railway vehicle bogie is reduced and the high-speed traveling dropped below the vehicle dynamic behaviour. Therefore, the adverse effects of the amount of a wheel imbalance on travel highlight the need for management of wheel imbalances. In addition, the static and dynamic management needs of a wheel imbalance need to be presented to the national rail vehicles operating agency.

Predicting Long-Term Shoreline Change Due to the Construction of Submerged Breakwaters in Manseongri Beach (잠제설치에 따른 만성리해빈에서 해안선의 장기변화 예측)

  • Park, Il Heum;Kang, Seong Wuk;Kang, Tae-Soon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.5
    • /
    • pp.527-535
    • /
    • 2016
  • The Manseongri Coast meets the sea on the southeast and is composed of coarse sediment as a mesotidal beach. The waves that strike the beach are stronger than the tides or tidal currents as external forces of beach deformation. Storm waves frequently reach significant wave heights of 2-3m and hit in spring and summer, leaving the sea calm during fall and winter. Incident waves reach remarkable heights that correspond with observed shoreline changes. The shoreline erodes in spring and summer due to these strong waves but recovers in fall and winter as a result of the more moderate waves. On the basis of these observed results, a numerical calibration for experiments on shoreline change was established. Results revealed that according to hindcast data, calculated shoreline changes agreed with the observed shoreline, with a minimum RMS error of 1.26m with calibration parameters $C_1=0.2$ and $C_2=1C_1$. Using these calibration parameters, long-term shoreline change was predicted after the construction of submerged breakwaters and jetties, etc. The numerical model showed that the shoreline would move forward by 5-15m behind the submerged breakwaters and recede by 5-15m north of the structure.

Design and Fabrication of Ka-Band Microstrip to Waveguide Transitions Using E-Plane Probes (E-평면 프로브를 이용한 Ka 대역 마이크로스트립-도파관 변환기의 설계 및 제작)

  • Shin, Im-Hyu;Kim, Choul-Young;Lee, Man-Hee;Joo, Ji-Han;Lee, Sang-Joo;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.76-84
    • /
    • 2012
  • In this paper, two kinds of E-plane microstrip-to-waveguide transitions are optimally designed and fabricated for combining output power from multiple small-power amplifiers in a WR-28 waveguide because conventional K connectors cause unnecessary insertion loss and adaptor loss. The transition design is based on target specifications such as a center frequency of 35 GHz, bandwidth of ${\pm}500MHz$, 0.1 dB insertion loss and 20 dB return loss. Performance variation caused by mechanical tolerance and assembly deviation is fully evaluated by three dimensional electromagnetic simulation. The fabricated back-to-back transitions with 16 mm and 26.57 mm interstage microstrip lines show insertion loss per transition of ~0.1 dB at 35 GHz and average 0.2 dB over full Ka band. Also the back-to-back transition shows return loss greater than 15 dB, which implies that the transition itself has return loss better than 20 dB.

Development of a Silicon Carbide Large-aperture Optical Telescope for a Satellite (SiC를 이용한 대구경 위성용 망원경 제작)

  • Bae, Jong In;Lee, Haeng Bok;Kim, Jeong Won;Lee, Kyung Mook;Kim, Myung-Whun
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.2
    • /
    • pp.74-83
    • /
    • 2022
  • The entire process, from the raw material to the final system qualification test, has been developed to fabricate a large-diameter, lightweight reflective-telescope system for a satellite observation. The telescope with 3 anastigmatic mirrors has an aperture of 700 mm and a total mass of 66 kg. We baked a silicon carbide substrate body from a carbon preform using a reaction sintering method, and tested the structural and chemical properties, surface conditions, and crystal structure of the body. We developed the polishing and coating methods considering the mechanical and chemical properties of the silicon carbide (SiC) body, and we utilized a chemical-vapor-deposition method to deposit a dense SiC thin film more than 170 ㎛ thick on the mirror's surface, to preserve a highly reflective surface with excellent optical performance. After we made the SiC mirrors, we measured the wave-front error for various optical fields by assembling and aligning three mirrors and support structures. We conducted major space-environment tests for the components and final assembly by temperature-cycling tests and vibration-shock tests, in accordance with the qualifications for the space and launch environment. We confirmed that the final telescope achieves all of the target performance criteria.

鐵鋼 溶接部의 균열發生과 그 試驗方法

  • 김영식
    • Journal of Welding and Joining
    • /
    • v.4 no.3
    • /
    • pp.13-25
    • /
    • 1986
  • 철강 구조물의 용접기술에 있어 용접부의 신속성을 좌우하는 가장 중요한 요소는 용접균열에 관한 문제와 용접본드부의 취화에 관한 문제로 요약될 수 있다. 일반적으로 용접부 및 그 근방의 금속은 국부적으로 매우 높은 온도까지 급열된 후 급냉되므로, 용접부에서 각종균열의 발성 위험성이 높아지고 용접본드부를 취화하여 파양인성의 저하를 초래하게 된다. 따라서 이러한 문 제점을 극복하기 위해서는 재료의 선택이나 설계, 시공, 검사의 각 단계에서 충분한 검토가 필 요하다. 특히 최근 들어 이전보다 높은 강도의 고장력강재가 널리 사용되고 구조물의 대형화에 따라 구속조건이 증대되며 구조물의 사용 조건은 더욱 가혹 화함에 따라 상술한 문제점은 더욱 중요시되고 있다. 철강 용접부에 발생하는 균열은 용접시공시 발생되는 균열과 용접완료후 구 조물 사용중에 발생되는 균열로 대별될 수 있다. 용접시공중 발생되는 균열은 용접열싸이클로 인해 생성되는 조직, 석출물등의 치금학적 요인과 잔유응력 또는 구속응력등의 역학적 요인이 중첩됨으로서 발생된다. 또한 사용중 발생되는 균열은 상기의 두 가지 요인이외에 환경적 요인이 첨가되어 발생된다고 볼 수 있다. 이상과 같은 용접균열을 방지하기 위해서는 실 구조물 용접 조립시의 각종 조건을 재현한 시험법을 통해 용접균열 발생의 한계조건을 정량적으로 분석할 필요가 있다. 이러한 균열 시험의 결과, 적정한 용접 시공 조건이 도출될 수 있기 때문이다. 이와 같은 필요성에 의해 지금까지 다수의 용접균열 시험법에 관한 연구가 행하여져 왔고 그 중에는 각 국가의 협회나 학회의 규격으로 확립된 것도 많으며 국제규격으로 되어 있는 것도 있다. 본 고에서는 각종균열들에 대한 지금까지 밝혀진 기구들에 대해 해설하고, 그 각각에 적용되고 있는 시험법들에 대해 소개하고저 한다.C1지구의 공업.생활용수는 103units, 33units로 배분되고, 하류지구에 304units로 배분되었다. 따라서 용도별로 물배분하므로서 금호강 하루지역에 더욱 많은 물을 배분할 수 있음을 알았다.통해서 수위-유량관계(rating curve)를 규명하였다. 시험지구의 관개효율 및 용수손실 규명 등에 관한 기본자료를 수집하기 위해서는 계측시스템의 운영은 장기간으로 지속 되어야 한다며, 전기전도도와 토양수 농도, 전기전도도와 함수량의 관계를 이용한 천이상태의 오염원 농도 측정방법을 개발하였다. 특히 제안식에서는 한계함수량의 개념을 도입하여 전기전도도와 함수량관계를 추정하므로 추정식의 실험값 반영 정도를 증가시켰다. 본 연구에서 제안된 식을 이용하여 추정된 전기전도도와 함수량관계는 다른 제안식에 비하여 개선된 결과를 보여 주었고, 본 연구에서 개발한 오염원 농도 측정법을 이용하여 측정한 결과 함수량이 0.15이하에서는 측정오차가 크지만 함수량이 0.15이상일 경우 매우 좋은 결과를 보였는데 질량평형을 검토한 결과 약 5-10%의 오차율을 보였다. 따라서 본 논문에서 개발된 천이상태의 오염원 농도측정법은 용존 오염물질의 이송에 관한 정확한 실험을 제공할 것으로 판단된다.며, 수질 보전적-환경 보전 차원에서 저수관리 체계를 확고히 할 수 있는 방안을 강구하여야 할 것이다.펄스주입법에 의해 증착된 박박은 강유전성 이력을 나타내었다.지역과 비도시지역을 비교하는 조사 연구가 필요하며, 이러한 조사결과를 바탕으로 자녀의 식습관에 대한 교육을 위한 교재, 교구의 개발과 영양, 식습관 교육프로그램의 개발을 통해 가정과 학교에서 부모와 교사가 자녀의 식생활 지도 관리를 돕고 가정과 교육기관이 연계한 교육 프로그램이 활성화 될 수 있도록 지속적인 관심을 기울여 나가야 할 것이며, 이에 따른

  • PDF

Statistical Analysis of Focus Adjustment Method for a Floating Imaging System with Symmetric Error Factors (대칭형 공차를 갖는 플로팅 광학계의 상면 변화 보정 방법에 대한 통계적 해석)

  • Ryu, Jae Myung;Kim, Yong Su;Jo, Jae Heung;Kang, Geon Mo;Lee, Hae Jin;Lee, Hyuck Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.5
    • /
    • pp.189-196
    • /
    • 2012
  • A floating optical system is a system that moves more than 2 groups to focus at the camera lens. At the camera optics, the floating system that is mainly used is an optical system such as a macro lens which changes magnification very much. When the floating system is assembled and fabricated in the factory, there are differences between the image plane of the sensor and the focal plane of the infinity or macro state. Therefore, in a considerable proportion of cases, the focus adjustment to minimize the difference of BWD(Back Working Distance) is carried out in the process of manufacturing. In this paper, in order to decide the movement of each group in a floating system, we evaluated the rotation angle of CAM for the focus adjustment. We know that the maximum magnification of macro state is corrected by this numerical method for the focus adjustment, too. We investigated the limit of CAM rotation angle of the system by using statistical analysis for CAM rotation angle, which uses the focus adjustment of the floating system with symmetric error factors.

Analysis of Dosimeter Error and Need for Calibration Guideline by Comparing the Dose Area of the Built-in Dose Area Product and the Moving Dose Area Product when using Automatic Exposure Controller in Intervention (인터벤션에서 자동노출제어장치 이용 시 내장형 면적 선량계와 이동형 면적 선량계의 면적선량 비교를 통한 선량계 오차분석과 교정지침 필요성 연구)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.508-515
    • /
    • 2018
  • The purpose of this study was to analyze the errors of the built - in dose area product and the calibrated moving dose area product when using automatic exposure controller of the interventional equipment. And then, the importance of the dosimeter calibration and the necessity of the calibration guideline were investigated. The experimental method was to assemble the phantom into Thin, Normal, and Heavy Adult according to the NEMA Phantom manual and to measure the dose area with the built-in dose area product and the moving dose area product. As a result, in all thicknesses, the built-in dose area product showed higher doses than the moving dose area product, and the thicker the thickness, the larger the difference. In addition, paired t-test was performed for each item and there was a significant difference in each item between p<0.05. In conclusion, considering the intervention which is highly exposed to the radiation exposure, it is that we have to know the accurate dose when using the AEC of the equipment. And there is no calibration guide for the built-in dose area meter, thus calibration guidelines should be prepared.