The suggestion of Steel Plate-Concrete Composite Beam Shape with Bolts (볼트 체결형 강판-콘크리트 합성보의 형상 제안)

  • Cho, Tae-Gu;Choi, Byong-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.305-314
    • /
    • 2018
  • The steel-plate concrete composite beam is composed of a steel plate, concrete and a shear connector to combine the two inhomogeneous materials. In general, the steel plate is assembled by welding an existing composite beam. In this study, a new steel-plate concrete composite (SPCC) beam was developed to reduce the size of the shear connector and improve its workability. The SPCC beam was composed of folded steel plates and concrete, without any shear connector. The folded steel plate was assembled with high strength bolts instead of welding. To improve the workability in field construction, a hat-shaped cap was attached in the junction with the slab. Monotonic two-point load testing was conducted under displacement control mode. The flexural strength of the SPCC beam specimen was calculated to be 76% of that of the complete composite beam by using the plastic stress distribution method and strain compatibility method. The cap acted as the stud and accessory. The synthesis rate could be increased by controlling the gap of the cap, and the bending performance could be evaluated by using the strain fitting method considering the synthesis rate of the SPCC beam.

Structural Analysis of Built-in Side-by-Side Refrigerator with Ice Dispenser and Home Bar and Evaluation of Door Differences and Gasket Gap (얼음디스펜서와 홈바가 있는 빌트인 양문형 냉장고의 구조해석 및 도어 단차와 개스킷 간극의 평가)

  • Ryu, Si-Ung;Lee, Boo-Youn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.465-473
    • /
    • 2018
  • A cabinet-door integrated finite element model for a built-in side-by-side refrigerator with an ice dispenser and home bar was constructed, and its deformation was analyzed by ANSYS. As loads, the food load in the shelf and baskets, and thermal load occurring during the normal operation condition were considered. From results of the analyses, the door height difference (DHD) and door flatness difference (DFD) between the two doors, and the increase in the gap of the door gasket, which affects the sealing of cool air in the cabinet, were derived. As results of an evaluation of the differences, the DHD and DFD under the assembled condition satisfied the acceptance criteria of the manufacturer. The food and thermal loads increased the DHD and DFD due to thermal deformation, and the DFD increased significantly. In addition, the increase in the gap of door gasket located between the cabinet and doors was derived from the results of displacements under the food and thermal loads. The evaluation showed that the maximum increase in gap appeared at the left edge of the freezing compartment gasket, which satisfied the acceptance criteria of the manufacturer.

Experimental Study on the Behavior of Building Hardware with Joint Details (접합 방법에 따른 하지철물 구조물의 거동에 관한 실험적 연구)

  • Hong, Seonguk;Kim, Seunghun;Baek, Kiyoul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.1
    • /
    • pp.190-198
    • /
    • 2018
  • In recent years, non-welded building hardware has been installed by bolt assembly is used. The non-welded building hardware method can reduce accidents caused by welding, and can be constructed by bolt assembly, which can reduce labor costs and shorten the construction period. However, there is a need for a method to compensate for the occurrence of buckling at the time of construction. The purpose of this study is to evaluate the behavior of joints between steel pipe and fastener and to evaluate the behavior of joints of non-welded and welded hardware frame. As a result, it was found that the foundation steel structure without welded joints was deformed to a rotation angle of member much larger than the allowable interlayer displacement angle 0.01 to 0.02 required according to the seismic load rating in the seismic load resistance system.

Study of laser welding for differential case & ring gear (레이저 용접에 관한 디퍼렌셜 케이스와 링기어 구조에 관한 고찰)

  • Chung, Taek-Min;Kim, Su-Lae;Rhee, Se-Hun
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.121-121
    • /
    • 2009
  • 자동차는 코너 주행 시 In-corner와 Out-corner 의 바퀴 궤적이 달라지므로, 특별한 장치가 없이 좌우 구동 측의 바퀴가 같은 속도로 회전을 하게 되면 정상적인 주행이 불가능하다. 따라서 정상적인 코너 주행이 가능 하려면, 코너 안쪽 바퀴보다 바깥쪽 바퀴가 더 빨리 회전해야 하며 이러한 회전 차를 보상받지 못할 경우 바깥쪽 바퀴가 끌리는 현상이 발생하는데 이를 방지하기 위해 디퍼렌셜 기어가 필요하다. 현재 디퍼렌셜 기어는 디퍼렌셜 케이스와 링기어를 볼트로 체결하는 조립 공법을 통해 생산되고 있다. 하지만 볼트 체결 공법은 조립을 위한 볼트와 볼트 체결을 위한 플랜지와 볼팅을 위한 홀을 가공하는 공정이 필요하기 때문에 재료비 절감 및 생산 효율 향상에 매우 불리하고 볼트체결을 위한 부분 때문에 불필요한 무게가 증가하게 된다. 따라서 본 연구에서는 이러한 기계적 체결 방식을 레이저 용접 방식으로 대체하여 재료비를 절감하고 무게 저감을 통해 주행성능을 향상시키고자 하였다. 링기어의 소재는 침탄처리강(SCM420H)이며 디퍼렌셜 케이스의 소재는 주철(GCD500)을 사용하고 있다. 주철은 용접시 용접부와 열영향부에서 마르텐사이트 조직과 레데브라이트, 시멘타이트 조직이 생성되며 고탄소 모재의 탄소 확산으로 인한 부분 혼합영역에서 탄소 합금이 생성되어 균열이 발생하는 등 용접성이 매우 좋지 않은 것으로 알려져 있다. 이러한 주철의 난용접성을 해결하는 방법으로는 고탄소 모재 용접시 발생하는 탄소의 확산을 억제하거나 예열이나 후열 처리를 통한 냉각 속도의 제어하는 방법과 오스테나이트 안정화 원소를 첨가한 필러와이어를 사용하여 용접시 마르텐사이트와 시멘타이트의 성장을 방해하는 방법 등이 이용되고 있다. 본 연구에서는 예열처리나 후열처리를 통한 주철의 용접법은 대량 생산을 통한 원가절감을 노리는 자동차 업계의 특성에 비추어 볼 때 비용이나 프로세스 구성 면에서 적용하는 것이 어려울 것이라 판단하여 Ni-base filler metal을 통한 주철의 용접법을 선택하였고 그 결과 실차에 적용하기 위한 비틀림 강성 테스트나 내구 테스트는 통과하였으나 NVH 테스트 결과 볼팅 체결 방식에 비하여 소음이 커지는 문제가 발생하고 링기어의 HAZ부가 고경화 되는 문제가 발생하였다. 때문에 용입깊이를 초기 시제품인 5mm에서 4mm로 변경시켜 입열량 감소 및 용접변형을 줄여 소음 문제를 해결하고자 하였으며 링기어의 침탄층을 1mm 절삭하여 링기어 HAZ부의 고경화 문제를 해결하고자 하였다. 이러한 용접 구조 변경이 용접변형 및 강성과 피로에 미치는 영향력을 알아보고자 용접 및 열처리 상용 소프트웨어인 SYSWELD, 구조해석 상용소프트웨어인 NX_NASTRAN, 피로 해석 상용 소프트웨어인 FEMFAT을 이용하여 시뮬레이션 하였고 실제 구조 변경한 용접 시제품과 비교, 분석하였다.

  • PDF

Experimental Study on the Shearing and Crushing Characteristics of Subaqueous Gravels in Gravel Bed River (수중 자갈의 전단 및 파쇄 특성에 관한 실험적 연구)

  • Kim, So-Ra;Jeong, Sueng-Won;Lee, Gwang-Soo;Yoo, Dong-Geun
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.164-174
    • /
    • 2021
  • The study examines the shearing and crushing characteristics of land-derived subaqueous granular materials in a gravel-bed river. A series of large-sized ring shear tests were performed to examine the effect of shear time and shear velocity on the shear stress characteristics of aquarium gravels with a 6-mm mean grain size. Three different shear velocities (i.e., 0.01, 0.1, and 1 mm/sec) were applied to measure the shear stress under the drained (long-term shearing) and undrained (short-term shearing) conditions. Different initial shear velocities, i.e., 0.01→0.1→1 mm/sec and 0.1→0.01→1 mm/sec, were considered in this study. The test results show that the grain crushing effect is significant regardless of drainage conditions. The shear stress of coarse-grained materials is influenced by initial shear velocities, regardless of the drainage conditions. In particular, particle breakage increases as grain size increases. The shearing time and initial shear velocity are the primary influencing factors determining the shear stress of gravels. The granular materials may be broken easily into particles through frictional resistance, such as abrasion, interlocking and fracture due to the particle-particle interaction, resulting in the high mobility of granular materials in a subaqueous environment.

Characteristics of Microcrack Development in Granite of the Mungyeong area in Korea (문경지역에 분포하는 화강암의 미세균열 발달특성)

  • 이병대;장보안;윤현수;이한영;진명식
    • The Journal of the Petrological Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.24-33
    • /
    • 1999
  • Differential Strain Analysis (DSA) was performed to examine the characteristics of microcracks for the granites from two sites, Noeunri and Gunggiri. The results of the DSA are taken every 5 MPa for the first 50 MPa, then every 10 MPa to a pressure of 100 MPa, and then every 15 MPa to a pressure of 250 MPa. Differential strain was measured on core samples in three horizontal directions, using $45^{\circ}$ rosette strain gages, and one vertical direction. The gradients of cumulative crack strain curves in one vertical direction and three horizontal directions differed from one another, indicating anisotropic crack development in the sample. The magnitude of vertical cumulative crack strain was the highest, indicating that the microcracks from the studied rock are generally developed in horizontal direction. Under the pressure of 240 Mpa, vertical cumulative crack strains for samples N-1, N-2, G-1, and G-2 were $74{\times}l0^{-6}~820{\times}l0^{-6},\; 190{\times}l0^{-6}~460{\times}l0^{-6},\; 329{\times}l0^{-6}~836{\times}l0^{-6},\; 833{\times}10^{-6}~1,592{\times}l0^{-6}$, respectively. Under the pressure of 25O MPa, volumetric crack strains for Gunggiri and Noeunri ranged from $1,804{\times}10^{-6}\; to\; 3,936{\times}10^{-6}\; and \;from,\; 1, 125{\times}10^{-6}\; to\; 1,457{\times}10^{-6}$, respectively. Therefore, the amount of microcrackes produced were more distributed in Gunggiri than Noeunri. The ratio of a maximum crack strain to a minimum crack strain was calculated to find the orientations between microcracks and the rift plane of the granites. Generally, the ratio has very high values ranging from 2.42 to 3.43, which suggests most microcracks to be intragranular cracks with the regular orientations. These results indicate that the preferred orientations of microcracks in the granites were almost parallel to the rift plane of the granites.

  • PDF

Study on Formation of FePd Nano-dot Using Agglomeration of Fe/Au Bilayer (Fe/Au 이중층의 응집현상을 이용한 FePd 나노 점 형성에 관한 연구)

  • Koo, J.K.;Kim, J.M.;Ryua, D.H.;Choi, B.J.;Kim, D.W.;Lee, D.H.;Kim, U.I.;Mitani, S.;J.G., M. Kamiko;Ha, J.G.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.7-13
    • /
    • 2011
  • [ $L1_0$ ]phase FePd nano-dot structures were successfully fabricated on self-organized Fe/Au bilayers. With atomic force microscopy, it is determined that surface morphologies of initially flat Fe/Au bilayer films were agglomerated and transformed their shape into nano-dots structures with increasing annealing temperature. With this bilayer as a template, FePd multilayers were deposited at various temperatures, i.e. $300^{\circ}C$, $350^{\circ}C$, $400^{\circ}C$, and $450^{\circ}C$. Surface morphologies of FePd superlattice had a near resemblance to self-organized bilayer. According to X-ray diffraction results, it is confirmed that $L1_0$ superlattice structures of FePd were obtained from samples which were annealed above $350^{\circ}C$. Results of X-ray photoelectron spectroscopy depth-profile analysis showed that chemical composition is identical to deposition sequence. As a result, without additional etching processes, fabrication of chemically ordered FePd superlattice nano-dots was achieved.

A Study on the Helical Gear Forming by Cold Extrusion (냉간 압출에 의한 헬리컬 기어의 제조에 관한 연구)

  • 최재찬;조해용;권혁홍;한진철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.127-138
    • /
    • 1991
  • A gear forming method by cold extrusion and an analytical method with its numerical solution program based on the upper bound method were developed. In the analysis the involute curve was as a shape of die and the upper bound method was used to calculate energy dissipation rate. By this method the power requirement and optimum conditions necessary for extruding helical(spur) gear were successfully calculated. These numerical solutions are in good agreement with experimental data. In the experiment, 4-6 class helical gear of KS standard for automobile transmission was successfully manufactured.

An Experimental Study on Flexural Behavior of One-Way Concrete Slabs Using Structural Welded Wire-Fabric (구조화 용접철강을 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구)

  • 허갑수;윤영호;양지수;김석중;정헌수
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.169-179
    • /
    • 1994
  • Recently the construction of residential buildings faces many difficulties due to the shortage of building materials and works. Simplifying the stage of processing and assembling reinforcing rods and increasing the efficiency of them in reinforced concrete construction can be used to settle the difficulties. In the respect, structural wire-fabric and loop wire-fabric is utilized. The purpose of this study, on condition of being $210kg/cm^2$ concrete strength, is to analyze the structural and flexural properties of one-way concrete slabs by testing with different reinforcing type, tensile steel ratio based with minimum steel ratio, boundary condition and splice length which affect the maximum width of crack and ductility factor. From the test results, the ductility factor is approved that the slabs using deformed bar were much better than that using wire-fabric, and 30D of splice length was appropriate in the slabs as splice length. In the control of the maximum crack width the slabs using wire-fabric and loop wire-fabric were much better than that using deformed bar.

A Experimental Study on the Structural Performance of Precast Bracket under Precast Road Deck Slab of Double Deck Tunnel (복층터널에서 도로용 중간슬래브와 연결되는 조립식 브라켓의 구조성능에 관한 실험연구)

  • Kim, Bo Yeon;Lee, Doo Sung;Kim, Tae Kyun;Kim, Young Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.647-657
    • /
    • 2017
  • The main purpose of this study is to investigate the static & dynamic behavior of a precast bracket under precast road deck slab of double deck tunnel. In order to improve the construction speed, the field prefabricated bracket to connect the intermediate slab to the precast shield tunnel lining structure has been developed in the 'SPC (Steel Precast Concrete) bracket'. The experiments were performed for the full scale model in order to evaluate the performance of the 'SPC bracket', the structural stability was verified through the FEM analysis. The result of static loading test, no deformations or cracks of the bracket undergo the ultimate load was investigated. In addition, no pulling or deformation of the chemical anchor for fixing the bracket was measured. As a result of dynamic loading test, it was investigated that there is no problem in the chemical anchor for fixing the bracket. FEM analysis showed similar behavior to static load test and it was determined that there is no problem in serviceability and structural safety.