An Experimental Study on Wind Aerodynamic Improvement of Steel Composite Cable Stayed Bridge having π-shaped Girder (π형 주형을 가진 강합성 사장교의 공기역학적 제진방법에 대한 실험적 연구)

  • Chang, Dong Il;Min, In Ki
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.801-811
    • /
    • 1998
  • In this paper, aerodynamic properties and improvements of the ${\pi}-shaped$ stiffening girder is studied by wind tunnel tests in steel composite cable stayed bridge. As an improvement device, fairing, extension, post and flap is tested. and the best improved section is selected and estimated on angles of attack, damping ratios and turbulent flows. It is shown that the selected fairing is effective to improve the aerodynamic stability. And this study can be utilized as a database of wind-resistant methodology of steel composite cable stayed bridge.

  • PDF

Performance and Manufacture of the Apparatus Generating Artificial Magnetic Field of 3-axis Type (3축형 인공자장발생장치의 제작과 성능에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.181-188
    • /
    • 2003
  • The objects of this study were to discuss the performance of its using magnetic compass and to do a trial manufacture of the apparatus generating artificial magnetic field of 3-axis type to assess the performance of compass using terrestrial magnetism in the various magnetic field. The results obtained were summarized as follows: The magnetic field of each axis showed the linearly increase in accordance with the increase of electrical current. Average range difference between measured and calculated values was 0.33∼1.93μT and there were no big difference. The magnitude and direction of magnetic field showed some change in the edge of Helmholtz coil, but it appeared to stabilize in the center. In the horizontal magnetic force of 0.30gauss and 0.40gauss, the measured and calculated values of the damping characteristic of magnetic compass showed a good agreement. However, the confidence level was low at the horizontal magnetic force of 0.50gauss.

An Experimental Study on the Structural Vibration Control Using Semi-Active Orificed Fluid Dampers (반능동형 오리피스 유체댐퍼를 이용한 구조물 진동제어에 관한 실험적 연구)

  • 문석준;김병현;정종안
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.2
    • /
    • pp.55-62
    • /
    • 2004
  • In general, control performance of the active control system is superior to that of the passive control devices. However, the active system require a large amount of external energy to operate the actuators. Semi-active control systems maintain the reliability of the passive control systems while taking advantage of the adjustability of the active control system. In this research, a semi-active orificed fluid damper having the capacity of about 2 tons was designed and fabricated. It is a two-stage damper with normally open solenoid valve. A series of tests was performed to grasp its performance characteristics. It was also applied to a 6-story steel structure subjected to random and seismic excitations for the confirmation of its validity on structural vibration absorption.

Modeling for Vibration Characteristics of Viscoelastic Material (점탄성 재료의 제진특성 모델링)

  • 이택희;박상규;김중배;이상조
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1146-1149
    • /
    • 2001
  • In this study, modeling methods for viscoelastic material are reviewed to investigate the vibration characteristics. Frequency response functions are obtained by employing experimental modal analysis and compared with the modeling results from a commercial software NASTRAN. Properties of equivalent model of the beam with damping material are also calculated by using the RKU equation.

  • PDF

A Study on the Dust Control Characteristics inside the Test Dome in the Port of Inchon (인천항 Dome내에서의 비산먼지 제진특성에 관한 연구)

  • 방진철;전기준;정용원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.425-426
    • /
    • 2000
  • 우리나라의 주항의 하나인 인천항을 통하여 수입되는 사료, 곡물, 고철등에 의하여 다량의 비산먼지가 발생하고 있으며, 인근지역에 심각한 피해를 입히고 있는 실정이다. 이러한 비산먼지로 인한 오염을 방지하기 위하여 현재 Dome이 설치되어 시범운영되고 있고, Dome 내부에서의 하역작업을 통하여 외부로의 비산먼지의 유출을 억제할 수 있다. 그러나 Dome 내부에서 사료등의 상ㆍ하차에 의하여 고농도의 분진이 발생되고 있는 실정이다. (중략)

  • PDF

An Assessment of the Filtration Characteristics of the Dust Emitting from Animal Feedstuff Handling (사료 부원료 하역과정에서 발생하는 비산먼지의 여과특성 평가)

  • 방진철;전기준;정용원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.95-96
    • /
    • 2001
  • 인천항은 한국의 주항의 하나로 원자재 수입화물을 취급하는 항만이다. 수입된 원자재 중에서 대두박등의 사료 부원료의 취급 시 강한 바람, 차량의 이동, 저장시설에서의 상하차 등에 의하여 다량의 비산먼지가 발생하여 인천항의 주된 비산먼지 오염원이 되고 있는 실정이다 (Jeon et al., 2000). 일반적으로 사료 부원료의 취급에 의하여 발생하는 비산먼지의 제진을 위하여, 사료 부원료 취급시설에 bag filter에 의한 제진시설이 사용되고 있다. (중략)

  • PDF

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.

Experimental Study for the Development of Vibration-Controlled Concrete (I) (진동제어 콘크리트 개발에 관한 실험적 연구(I))

  • 정영수;이대형;최우성
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.123-133
    • /
    • 1996
  • Recently, the construction of infrastructures has been booming and accelerating to keep up with rapid economic growth. Construction activities and operation of transportation facilities cause unfavorable effects such as civil petitions associated with vibration-induced damages or nuisances. Accordingly, the objective of this study is to develop vibration-controlled concrete using various vibration-controlled mixtures, and also to recycle obsolete materials in part. As the first step to achieve this research, preliminary mix designs have been carried out to obtain an appropriate mix proportion above 200kg/$\textrm{cm}^2$ in uniaxial compressive strength. Test specimen based on the mix proportion selected have been actuated by the impact hammer to investigate their dynamic characteristics. Vibration-controlled mixtures are foam, latex, rubber powder and plastic resin, which have been determined to reduce a vibration by and large. KS F2437 and travel time method have been used to figure out 1st natural frequency and dynamic elastic moduli. Damping ratios have been computed by adopting the polynomial curvefitting method and the geometric analysis method on the frequency response spectrum curve. of which results have been compared and analyzed hereon.

A Study for Stamping of Patchwork with Resistance Spot Weld (저항 점용접에 의한 실러 패치워크 적용 판재 프레스 성형 연구)

  • Lee, Gyeong-Min;Jung, Chan-Yeong;Song, Il-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.25-31
    • /
    • 2018
  • Recently, research on the development of lightweight vehicle bodies is increasing continuously as a response to fuel economy regulations. To reduce the weight of a vehicle body, a conventional steel plate has been substituted by light weight material with high specific strength and the jointing of multi-materials is generally applied. On the other hand, the customer's demand for safety and emotional quality in NVH (Noise, Vibration and Harshness) is becoming increasingly important. Therefore, a light weight with proper strength and NVH quality is needed. In the view of light weighting and NVH quality, the application of a vibration proof steel plate can be an effective solution but the formability of a sandwich panel is different with a conventional steel sheet. Therefore, careful analysis of formability is required. This study aims to characterize the formability of a sandwich high-strength steel plate. The high-strength steel plates of different thicknesses with resistance spot welding and sealer bonding were analyzed using forming limits diagram through a cup drawing test.

A Study on Dynamic Modeling of the Vibration Isolation System for the Ultra Precision Measurement (초정밀작업을 위한 제진시스템의 동역학 모델링 연구)

  • Son, Sung-Wan;Jang, Sung-Ho;Baek, Jae-Ho;Chun, Chong-Keun;Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.25-31
    • /
    • 2009
  • The anti-vibration tables that use air suspensions as dampers have been widely used due to their high anti-vibration performance in wide frequency band. However, they face a problem of easily accelerating the vibration when triggered by external force because their air suspensions have low rigidity and dampness. In response, there has been a study on active/semi-active dampers that use only the passive components like air suspensions to complement the passive-control format. Thus, we have dynamically analyzed the active/semi-active control of such passive anti-vibration tables. To demonstrate the anti-vibration table's control system, we have also constructed a kinetic model based on the physical characteristics of an anti-vibration table with 6 degrees of freedom and verified its applicability through analysis and experiments.