• Title/Summary/Keyword: 제작방법

Search Result 9,967, Processing Time 0.041 seconds

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

The Localization of the Excretory, Purified and Infected Antigenic Protein in the Tissue of Trichinella spiralis Larval Worm (선모충(Trichinella spiralis) 유충의 조직 내 배설, 분리 및 감염항원 단백의 분포)

  • Kim, Soo-Jin;Joo, Kyoung-Hwan;Chung, Myung-Sook;Rho, Young-Bok
    • Applied Microscopy
    • /
    • v.37 no.1
    • /
    • pp.43-52
    • /
    • 2007
  • In order to observe the localization of excretory, purified and infected antigenic protein in the tissue of Trichinella spiralis larvae, immunogoldlabeling methodology using IgG and protein A-gold complex was implemented. T. spiralis larvae obtained from rat muscle were initially cultured in medium, and secreted excretory antigen was collected for 1 or 3 days. Purified antigenic protein was obtained from homogenized T. spiralis larvae. Rabbits were then immunized with 1 or 3 days secreted excretory protein and purified 45 kDa protein, and IgG was purified from collected serum. Serum, against infected antigen, collected from rat on 1 and 4 weeks after infection with T. spiralis larvae, and IgG was purified from collected serum. T. spiralis larvae were embedded in Lowicryl HM20 medium. Then they were finally treated with immunized IgG and protein A-gold complex (particle size; 15 nm) and observed under electron microscope. In T. spiralis larvae tissue, the tissue antigen reacted with rabbit IgC antigen Day 1 secreted excretory protein, infected antigenic protein and purified 45 kDa protein. But different distribution pattern of labeled gold particles were observed. When Day 1 secreted excretoy protein was used, gold particle labeling was observed specifically on the cuticle, basal layer, esophagus interstitial matrix (EIM) and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte of the worm. In a separate group of tissue, the antigen reacted with rabbit IgG against Day 3 secreted excretory protein. Labeled gold particles were specifically distributed on the surface layer of cuticle, EIM and ${\alpha}_0$ granules of stichocyte of the worm. In case of using infected antigenic protein, gold particle labeling was specifically distributed on the cuticle and EIM of the worm. When purifed 45 kDa protein was used gold particle labeling was specifically distributed on the cuticle, basal layer, EIM and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte of the worm. Therefore, excretory antigens appeared to originate from the cuticle and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte for the first day but the cuticle layer associated with globular proteins and ${\alpha}_0$ granules of stichocyte after 3 days and infected antigens appeared to originate from the cuticle for 1 and 4 weeks after infection. These results suggest that excretory and infection specific antigens are secreted into the cuticle, basal layer, EIM and ${\alpha}_0,\;{\alpha}_1$ granules of stichocyte and 45 kDa protein may be contained these specific antigens.

A Study on Sensibility Evaluation of Ceramic Surface: Comparison between Tactility and Visual Tactility (세라믹 표면의 감성 평가 연구: 촉감과 시각적 촉감의 비교를 중심으로)

  • Kim, Jihyun;Song, Min Jeong
    • Science of Emotion and Sensibility
    • /
    • v.19 no.2
    • /
    • pp.101-112
    • /
    • 2016
  • Selecting appropriate materials can be significantly important to make different image in the product and also give distinguished express to the users. A material for the ceramic product surface consists of the combination between a glaze and a body, and each attribution of materials and the way of the combination creates different texture and color. This study analyzes the difference between visually and tactually sensibility of ceramic surface to through the simulating both visual and tactual stimulation by verbal evaluation method. Totally 13 adjectives are selected from homepage of local and global ceramic product brand. And totally 12 ceramic samples are created with the consideration of color, glossiness and roughness. These 12 samples are the combination between four ceramic bodies (White porcelain, Celadon_c, Sancheong and Black soil) and three glazes (Transparent, Celadon_g, Black glaze). The respondents of first survey were asked to rub, touch and hold before evaluating the sensibility of ceramic surface and other respondents of second survey were asked to evaluate visual images of 9 samples which showed meaningfully difference from first survey. The surface which scored the highest sensibility with the first survey was 'pure' on a surface of White porcelain body with Transparent glaze, and the lowest was also 'pure' on a surface of Black soil body with Transparent glaze. The highest score in the second survey was the same result as the first survey, but the lowest scored 'casual' and the surface was Black soil body with Celadon glaze. By the comparison with two survey results, not every sensibility is same result shown as the first survey and the second survey, but the tactile sensibilities such as 'artistic', 'luxurious', 'sensuous', 'romantic' and 'mysterious' can be experienced by via visual materials of ceramic surfaces.

Effect of infection control barrier thickness on light curing units (감염 조절용 차단막의 두께가 광중합기의 중합광에 미치는 영향)

  • Chang, Hoon-Sang;Lee, Seok-Ryun;Hong, Sung-Ok;Ryu, Hyun-Wook;Song, Chang-Kyu;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.368-373
    • /
    • 2010
  • Objectives: This study investigated the effect of infection control barrier thickness on power density, wavelength, and light diffusion of light curing units. Materials and Methods: Infection control barrier (Cleanwrap) in one-fold, two-fold, four-fold, and eightfold, and a halogen light curing unit (Optilux 360) and a light emitting diode (LED) light curing unit (Elipar FreeLight 2) were used in this study. Power density of light curing units with infection control barriers covering the fiberoptic bundle was measured with a hand held dental radiometer (Cure Rite). Wavelength of light curing units fixed on a custom made optical breadboard was measured with a portable spectroradiometer (CS-1000). Light diffusion of light curing units was photographed with DSLR (Nikon D70s) as above. Results: Power density decreased significantly as the layer thickness of the infection control barrier increased, except the one-fold and two-fold in halogen light curing unit. Especially, when the barrier was four-fold and more in the halogen light curing unit, the decrease of power density was more prominent. The wavelength of light curing units was not affected by the barriers and almost no change was detected in the peak wavelength. Light diffusion of LED light curing unit was not affected by barriers, however, halogen light curing unit showed decrease in light diffusion angle when the barrier was four-fold and statistically different decrease when the barrier was eight-fold (p < 0.05). Conclusions: It could be assumed that the infection control barriers should be used as two-fold rather than one-fold to prevent tearing of the barriers and subsequent cross contamination between the patients.

Optimization of the cryopreserved condition for utilization of GPCR frozen cells (GPCR 냉동보관 세포의 활용을 위한 냉동조건의 최적화 연구)

  • Noh, Hyojin;Lee, Sunghou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1200-1206
    • /
    • 2015
  • The major target for drug discovery, G-protein coupled receptor (GPCR) is involved in many physiological activities and related to various diseases and disorders. Among experimental techniques relating to the GPCR drug discovery process, various cell-based screening methods are influenced by cell conditions used in the overall process. Recently, the utilization of frozen cells is suggested in terms of reducing data variation and cost-effectiveness. The aim of this study is to evaluate various conditions in cell freezing such as temperature conditions and storage terms. The stable cell lines for calcium sensing receptor and urotensin receptor were established followed by storing cultured cells at $-80^{\circ}C$ up to 4 weeks. To compare with cell stored at liquid nitrogen, agonist and antagonist responses were recorded based on the luminescence detection by the calcium induced photoprotein activation. Cell signals were reduced as the storage period was increased without the changes in $EC_{50}$ and $IC_{50}$ values $EC_{50}:3.46{\pm}1.36mM$, $IC_{50}:0.49{\pm}0.15{\mu}M$). In case of cells stored in liquid nitrogen, cell responses were decreased comparing to those in live cells, however changes by storage periods and significant variations of $EC_{50}/IC_{50}$ values were not detected. The decrease of cell signals in various frozen cells may be due to the increase of cell damages. From these results, the best way for a long-term cryopreservation is the use of liquid nitrogen condition, and for the purpose of short-term storage within a month, $-80^{\circ}C$ storage condition can be possible to adopt. As a conclusion, the active implementation of frozen cells may contribute to decrease variations of experimental data during the initial cell-based screening process.

Effects of the mascara and eye shadow on theMR image distortion (자기공명영상 왜곡에서 마스카라와 아이섀도의 영향)

  • Lee, Hyun-Yong;Shin, Oun-Jae;Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.

  • PDF

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Analyses of Genetic Relationships of Rhizoctonia solani Isolates from Various Crop Species and Rapid Identification of Anastomosis Groups with RAPD Method (각종 작물에서 분리한 R. solani 균주들의 RAPD를 이용한 종내 그룹의 유전적 유연관계 분석 및 AGs 신속 간이동정)

  • Lee, Youn-Su;Choi, Hei-Sun;Kim, Kyoung-Su;Woo, Su-Jin;Kang, Won-Hee;Kim, Myoung-Jo;Shim, Jae-Ouk;Lee, Min-Woong
    • The Korean Journal of Mycology
    • /
    • v.26 no.3 s.86
    • /
    • pp.373-379
    • /
    • 1998
  • Rhizoctonia solani [Thanatephorus cucumeris (frank) Donk], one of the major soil-borne plant pathogens with world-wide distribution, can cause great damages on various crops. In Korea, sheath blight on rice caused by this pathogen is the major concern, and active studies on this pathogen have been performed. However, most of these studies were concerned with pathogenicity of the isolates instead of molecular analyses of different AGs of R. solani. Therefore, in this study, thirty isolates of Rhizoctonia solani collected from various sources were used for the analyses of genetic relationships among themselves and for the rapid anastomosis grouping with RAPD method. As a result, thirty isolates of known and unknown AGs were grouped into five subgroups and each group included AG-1, AG-2, AG-3, AG-4, and AG-5. RS-1 isolate was found to be closely related to AG-5. Isolates RS-4, RS-14, RS-17, and RS-16 were found to be closely related to AG-2-2(III B). Isolate RS-13 was closely related to AG-4, isolates RS-8 and RS-10 were closely related to AG-1(I B), and isolates RS-7 and RS-21 were closely related to AG-2-2(IV). Isolate RS-19 was closely related to AG-1(I C), and isolates RS-3, RS-5, RS-18, RS-6, and RS-15 were found to be closely related to AG-1.

  • PDF

Understanding the Response Characteristics of X-ray Verification Film (X-선 Verification 필름의 반응 특성에 관한 연구)

  • Yeo Inhwan;Seong Jinsil;Chu Sung Sil;Kim Gwi Eon;Suh Chang Ok;Burch Sandra E.;Wang Chris K.
    • Radiation Oncology Journal
    • /
    • v.16 no.4
    • /
    • pp.505-515
    • /
    • 1998
  • Purpose : This study is intended to understand the sensitometric characteristics and the emulsion properties of the commercially available CEA TVS film in comparison with the Kodak X-Omat V film. Materials and Methods : For this purpose, we have formulated an analytic expression of the characteristic curves for x-ray film exposed to mixed radiation of electrons, photons, and visible light. This mathematical expression was developed based on reaction-rate and target-hit theories. Unlike previous expressions. it relates optical density to emulsion properties such as grain size and silver bromide content We have also developed a quantity which characterizes the film response to visible light relative to that to photons and electrons. This quantity could be expressed as a function of grain area. Thus, we have developed mathematical expressions and quantities with which the emulsion properties of the films can be revealed based on the sensitometric characteristics. Demonstrating the use of this analytical study, we exposed CEA and Kodak verification films to the mixed radiation of electrons, photons, and visible light, and interpreted the experimental results accordingly. Results : We have demonstrated that: (1) the saturation density increases as the silver bromide content increases, (2) the time required to reach the threshold dose (to which the film begins to respond) when films are exposed to visible light decreases as the grain size increases, and (3) the CEA film contains more silver bromide. whereas the Kodak film contains larger grains. These findings were supported by the data provided by the manufacturers afterward. Conclusion : This study presented an analytical and experimental basis for understanding the response of X-ray film with respect to the emulsion properties.

  • PDF