• Title/Summary/Keyword: 제어체적

Search Result 176, Processing Time 0.023 seconds

Development of a portable power supply employing bidirectional energy flows (양방향 전력수수가 가능한 이동식 전원장치의 개발)

  • 강필순;이정한;박성준;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.339-345
    • /
    • 2002
  • This paper presents a portable power supply equipped with a battery charger. The proposed system can be operated separatedly distinguishing between DC/AC and AC/DC function. The former uses a battery and the latter a line voltage as the power source to operate on an inverter and a battery charger, respectively. To keep the output voltage being sinusoidal and to have the high dynamic performances even In the cases of load variations, a proper control method is adapted. The operational principles and analysis are explained in detail. The validity of the proposed system is proved from the experimental results.

Strength Character of the Condition of Consolidated Constant pressure with Improvement One-Dimension Shearing Test and Simple Shearing Test (정압(CD)조건의 개량형 일면전단시험과 단순전단시험에 있어서 강도특성에 관한 연구)

  • Kim, Jae-Young;Ohshima, Akihiko;Takada, Naotoshi;Kim, Dong-Hyun;So, Choong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.131-136
    • /
    • 2006
  • 일면전단시험은 전단면의 응력을 직접 측정하므로 평면변형시 강도를 파악할 수 있는 등의 많은 장점을 가지고 있으며, 시험조작이 간편하기 때문에 실용적으로도 우수한 것으로 판단된다. 그러나 사질토의 경우에 의한, Dilatancy에 의한 체적변화과정에서 공시체와 전단상자의 주면마찰력이 전단면의 수직 응력을 증감시키기 때문에 구해지는 강도가 과대 또는 과소하게 나타나는 것으로 알려져 있다. 그러나 반력판측에 장착한 하중계를 통해 전단면의 수직응력을 직접 측정 제어하는 형식으로 개선되어 주면마찰력의 영향을 해소하였다. 따라서 본 연구는 반력판측에 하중계를 장착한 개량형 다단식 단순전단시험기를 개발하여 사질토의 정압(CD)조건 전단시험을 수행하여 강도특성과 전단강도에 미치는 영향을 개량형 일면전단시험의 결과와 비교하였다. 그 결과 정압조건의 일면전단시험과 단순전단시험에 의한 강도정수는 조밀한 모래의 경우는 거의 비슷하게 나타나며, 느슨한 모래의 경우는 일면전단이 다소 크게 나타났다. 그리고 단순전단과 일면전단시험에서의 Dilatancy거동에는 큰 차이가 나타나지 않았다.

  • PDF

Flow and Combustion Characteristics according Control Strategy of Variable Valve Duration System for Compression Ignition Engine (압축착화기관용 가변밸브 듀레이션(VVD)시스템의 제어전략에 따른 유동 및 연소성능 해석)

  • Cho, Insu;Kim, Wootaek;Lee, Jinwook
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.45-50
    • /
    • 2020
  • Recently, global warming and environmental pollution are becoming more important, and fuel economy is becoming important. Each automobile company is actively developing various new technologies to increase fuel efficiency. CVVD(Continuously Variable Valve Duration) system means a device that continuously changes the rotational speed of the camshaft to change the valve duration according to the state of the engine. In this paper, VVT(Variable Valve Timing) and CVVD were applied to a single-cylinder diesel engine, and the characteristics of intake and exhaust flow rate and in-cylinder pressure characteristics were analyzed by numerical analysis. In order to analyze the effect of CVVD on the actual engine operation, the study was performed by setting the valve control and injection pressure as variables in two sections of the engine operating region. As a result, In the case of applying CVVD, the positive overlap with the exhaust valve is maintained, thus it is possible to secure the flow smoothness of air and increase the volumetric efficiency by improving the flow rate. The section 2 condition showed the highest peak pressure, but the pressure rise rate was similar to that of the VVT 20 and CVCD 20 conditions up to 40 bar due to the occurrence of ignition delay.

Vertical Convection Flow around V-Shaped Structures in Uniform Current (조류 중에 놓인 V-형 구조물 주위의 연직순환류에 대한 연구)

  • Yang, Chan-Kyu;Hong, Keyyong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.34 no.4
    • /
    • pp.148-157
    • /
    • 1997
  • In this paper, the flow around a V-shaped plate positioned against horizontal flow is numerically simulated by using finite volume method and experimentally visualized in two dimensional tank by dye injection method. The upwelling flow artificially induced by V-shaped plate mixes the stratified stagnant flow. It can be applied to mitigate the eutrophication and stratification of sea in the vicinity of offshore structures.

  • PDF

가압 경수로(PWR)원전 CVCS 정화 탈염기의 $^{7}$ Li$_3$ 회수 운전 방안 운전 방안

  • 성기방
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.392-397
    • /
    • 1998
  • PWR 원전의 냉각재 화학 및 체적제어 계통(CVCS) 정화 탈염기는 핵연료에서 방출된 핵분열 생성물질과 방사성 부식생성물을 제거하여 계통 내 방사능 준위를 낮추고, 부식을 유발하는 불순물을 제거하여 계통의 건전성을 유지하며, pH 조절제인 리튬($^{7}$ Li$_3$)의 농도조절을 통해 냉각계 수화학 환경을 최적으로 유지시킨다. 이를 위해 CVCS에는 정화용 혼상 탈염기와 $^{7}$ Li$_3$ 조절용 양이온 탈염기가 설치되었으며, 각각의 탈염기는 독립적인 기능을 수행한다. 이는 원전 운전 중 중성자와 붕소($^{10}$ B$_{5}$ )의 핵반응으로 생성된 $^{7}$ Li$_3$3 의 회수가 불가능하기 때문에 정화 탈염기에는 값비싼 $^{7}$ Li$_3$ 포화형 수지를 충전하여야 한다. Pn 원전은 연료교체를 위해 주기적으로 연료계장전 기간을 갖으며 이에 따라 원자로 기동 수화학, 운전중 B/Li 농도조절에 의한 pH 화학, 원자로 정지화학 등의 주기적인 냉각재 수화학 관리를 해오고 있다. 본 연구에서는 효율적인 정화탈염기의 운영방안을 제시함으로 운전중 붕소의 핵분열로 생성되는 $^{7}$ Li$_3$ 의 회수가 가능하고 수지의 사용량 절감으로 수지폐기물 발생량 저감화를 이를 수 있을 것으로 기대된다.

  • PDF

Study on the Temperature Characteristic of Pressurization System Using Cryogenic Helium Gas (극저온 헬륨가스 가압시스템에 대한 온도특성 연구(I))

  • Chung Yonggahp;Kim Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.66-73
    • /
    • 2005
  • The pressurization system in a liquid rocket propulsion system provides a controlled gas pressure in the ullage space of the vehicle propellant tanks. It is advantage to employ a hot gas heat exchanger in the pressurization system to increase the specific volume of the pressurant and thereby reduce over-all system weight. A significant improvement in pressurization-system performance can be achieved, particularly in a cryogenic system, where the gas supply is stored inside the cryogenic propellant tank. In this study liquid nitrogen was used instead of liquid oxygen as a simulant. The temperature characteristic of cryogenic pressurant is very important to develop some components in pressurization system. Numerical modeling and test data were studied using SINDA/FLUINT Program and PTF(Propellant-feeding Test facility).

Basic Model for Propellant Tank Ullage Calculation (추진제탱크 얼리지 해석을 위한 기본모델)

  • Kwon, Oh-Sung;Cho, Nam-Kyung;Cho, In-Hyun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.125-132
    • /
    • 2010
  • Estimation of pressurant mass flowrate and its total mass required to maintain propellant tank pressure during propellant outflow is very important for design of pressurization control system and pressurant storage tank. Especially, more pressurant mass is required to maintain pressure in cryogenic propellant tank, because of reduced specific volume of pressurant due to heat transfer between pressurant and tank wall. So, basic model for propellant tank ullage calculation was proposed to estimate ullage and tank wall temperature distribution, required pressurant mass, and energy distribution of pressurant in ullage. Both test and theoretical analysis have been conducted, but only theoretical modeling method was addressed in this paper.

A Passive Control of the Unsteady Shock-Boundary Layer Interaction in Propulsion Nozzle (추진 노즐에서 발생하는 비정상 충격파-경계층의 간섭현상의 피동제어)

  • Lee, Jong-Sung;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.211-214
    • /
    • 2011
  • In the present work, a computational study was conducted to investigate characteristic of lateral force on the flow fields inside the propulsion nozzle with step. The unsteady, compressible, axisymmetric, Navier-Stocks equations with SST k-${\omega}$ turbulence model are solved using a fully implicit finite volume scheme. In order to simulate the shut-down process of the engine, NPR is varied from 100.0 to 10.0. It is observed that the separation point and Mach-disk strongly depend on the variation of NPR, and adjusting the step lead to significantly different characteristics in the lateral forces.

  • PDF

Comparison of Dose Distribution in Spine Radiosurgery Plans: Simultaneously Integrated Boost and RTOG 0631 Protocol (척추뼈전이암 환자의 체부정위방사선치료계획 비교: 동시통합추가치료법 대 RTOG 0631 프로토콜)

  • Park, Su Yeon;Oh, Dongryul;Park, Hee Chul;Kim, Jin Sung;Kim, Jong Sik;Shin, Eun Hyuk;Kim, Hye Young;Jung, Sang Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.176-184
    • /
    • 2014
  • In this study, we compared dose distributions from simultaneously integrated boost (SIB) method versus the RTOG 0631 protocol for spine radiosurgery. Spine radiosurgery plans were performed in five patients with localized spinal metastases from hepatocellular carcinoma. The computed tomography (CT) and T1- and T2-weighted magnetic resonance imaging (MRI) were fused for delineating of GTV and spinal cord. In SIB plan, the clinical target volume (CTV1) was included the whole compartments of the involved spine, while RTOG 0631 protocol defines the CTV2 as the involved vertebral body and both left and right pedicles. The CTV2 includes transverse process and posterior element according to the extent of GTV. The doses were prescribed 18 Gy to GTV and 10 Gy to CTV1 in SIB plan, while the prescription of RTOG 0631 protocol was applied 18 Gy to CTV2. The results of dose-volume histogram (DVH) showed that there were competitive in target coverage, while the doses of spinal cord and other normal organs were lower in SIB method than in RTOG 0631 protocol. The 85% irradiated volume of VB in RTOG 0631 protocol was similar to that in the SIB plan. However, the dose to normal organs in RTOG 0631 had a tendency to higher than that in SIB plan. The SIB plan might be an alternative method in case of predictive serious complications of surrounded normal organs. In conclusion, although both approaches of SIB or RTOG 0631 showed competitive planning results, tumor control probability (TCP) and normal tissue complication probability (NTCP) through diverse clinical researches should be analyzed in the future.

Evaluating the Dosimetric Characteristics of Radiation Therapies according to Head Elevation Angle for Head and Neck Tumors (두 경부 종양 치료 시 거상각도에 따른 치료기법 별 선량특성 평가)

  • Cheon, Geum-Seong;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.14-24
    • /
    • 2016
  • Since the head and neck region is densely located with organs at risk (OAR), OAR-sparing is an important issue in the treatment of head and neck cancers. This study-in which different treatment plans were performed varying the head tilt angle on brain tumor patients-investigates the optimal head elevation angle for sparing normal organs (e.g. the hippocampus) and further compares the dosimetric characteristics of different types of radiation equipment. we performed 3D conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and tomotherapy on 10 patients with brain tumors in the frontal lobe while varying the head tilt angle of patients to analyze the dosimetric characteristics of different therapy methods. In each treatment plan, 95% of the tumor volume was irradiated with a dose of 40 Gy in 10 fractions. The step and shoot technique with nine beams was used for IMRT, and the same prescription dose was delivered to the tumor volume for the 3D-CRT and tomotherapy plans. The homogeneity index, conformity index, and normal tissue complication probability (NTCP) were calculated. At a head elevation angle of $30^{\circ}$, conformity of the isodose curve to the target increased on average by 53%, 8%, and 5.4%. In 3D-CRT, the maximum dose received by the brain stem decreased at $15^{\circ}$, $30^{\circ}$, and $40^{\circ}$, compared to that observed at $0^{\circ}$. The NTCP value of the hippocampus observed in each modality was the highest at a head and neck angle of $0^{\circ}$ and the lowest at $30^{\circ}$. This study demonstrates that the elevation of the patients' head tilt angle in radiation therapy improves the target region's homogeneity of dose distribution by increasing the tumor control rate and conformity of the isodose curve to the target. Moreover, the study shows that the elevation of the head tilt angle lowers the NTCP by separating the tumor volume from the normal tissues, which helps spare OARs and reduce the delivered dose to the hippocampus.