• Title/Summary/Keyword: 제어밸브

Search Result 894, Processing Time 0.031 seconds

A Study on Flow Control Logic Valve - Static Characteristics of Proportional Poppet Type Logic Valve - (유량제어 로직 밸브에 관한 연구 ( 비례 파핏형 로직 밸브의 정특성 ))

  • Lee, Il-Yeong;Jeong, Yong-Gil;O, In-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.26 no.2
    • /
    • pp.213-217
    • /
    • 1990
  • This study suggests a new type flow control logic valve which have grooves on the main poppet valve. The grooves connect oil supply port to pilot chamber and the oil passages made by the grooves are designed to vary in proportion to the displacement of the main poppet valve. From analytical formulations on the hydraulic circuit including the flow control valve, equations on the characteristics of the valve were obtained. In the experiment, the relationships between valve displacement and flow rate to the load side, and the variations of flow rate to the load side according to the variation of load pressure were investigated. From the experimental and numerical results, it was ascertained that the flow control valve designed in this study had excellent characteristics on proportional control and remote control.

  • PDF

Implementation of a Control Valve Model in Simulator to Test a Turbine Control System (발전소 터빈제어 검증용 시뮬레이터의 유량 제어밸브 모델 구현)

  • Woo, Joo-Hee;Kim, Jong-An;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1680_1681
    • /
    • 2009
  • 복잡한 이론적인 지식이 없어도 대상 발전소의 운전데이터를 밸브의 유량특성 관계 값에 지정함으로써 쉽게 모델링할 수 있도록 터빈제어 밸브 모델을 구현하였다. 또한 제어밸브의 여러 가지 동작 특성을 입력할 수 있는 사용자 인터페이스를 구현하였다. 이렇게 구현된 모델을 사용하여 직접 터빈제어시스템과 연계하여 모의시험 하였으며 만족스러운 결과를 보여주었다.

  • PDF

Characteristics of Heat Transfer in a Heat pipe Controlled by Solenoid Valve (전자 밸브에 의해서 제어되는 히트파이프의 전열 특성)

  • Jun, C.H.;Jang, Y.S.;Kim, O.G.
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.103-111
    • /
    • 1997
  • The purpose of this research is the study of characteristics of heat transfer in a heat pipe controlled by solenoid valve. A solenoid valve located to the adiabatic section between evaporator and condenser of heat pipe was used to control the valve action for effective energy transfer of the industrial exchanger machine. By the results presented in this study temperature difference between evaporator and condenser increases with increasing the temperature frequency and with decreasing the temperature amplitude. When inclination angle and flow rate of cooling water increases, the temperature amplitude is reached to the steady state rapidly with increasing the temperature frequncy.

  • PDF

Solenoid Valve DCC-PWM Control for Diesel Engines Fuel Pump (디젤엔진 연료펌프의 솔레노이드 밸브 DCC-PWM 제어)

  • 신우석;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.85-91
    • /
    • 1998
  • This paper describes an study electric injection system for diesel engines. It is needed effective fuel injection which controls the solenoid valve of fuel pump. To solve this, this paper proposes DCC-PWM method which can realize fast reply and low holding current for solenoid valve on/off. For the proposed design method, simulation tools of ACSL are used to analyze the system. And the single-chip microcomputer is used to reduce the size of controller and to improve flexibility. And the systems validity can be verified through the experimental results.

Auto Tuning of Position Controller for Proportional Flow Control Solenoid Valve (비례유량제어밸브 위치제어기 자동조정)

  • Jung, Gyu-Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.797-803
    • /
    • 2012
  • Proportional solenoid valves are a modulating type that can control the displacement of valves continuously by means of electromagnetic forces proportional to the solenoid coil current. Because the solenoid-type modulating valves have the advantages of fast response and compact design over air-operated or motor-operated valves, they have been gaining acceptance in chemical and power plants to control the flow of fluids such as water, steam, and gas. This paper deals with the auto tuning of the position controller that can provide the proportional and integral gain automatically based on the dynamic system identification. The process characteristics of the solenoid valve are estimated with critical gain and critical period at a stability limit based on implemented relay feedback, and the controller parameters are determined by the classical Ziegler-Nichols design method. The auto-tuning algorithm was verified with experiments, and the effects of the operating point at which the relay control is activated as well as the relay amplitude were investigated.

Effect of Reynolds Number on the Flow Characteristics of a Control Valve (제어밸브 유량특성에 레이놀즈 수가 미치는 영향)

  • Jung, Taekyu
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.995-999
    • /
    • 2017
  • The factors affecting the flow coefficient of a control valve were identified and analyzed. The flow coefficient of a control valve are affected by not only Reynolds Number but also the figure and the roughness of the inlet/outlet pipes. Therefore, the flow coefficient is not a constant value. For the purpose of use in the system such as LRE, requiring the exact flow-coefficient of a control valve, the flow-coefficient should be measured under similar Reynolds Number using the inlet and outlet pipes which have the same figure and roughness with a real system.

  • PDF

Experimental Study of Operating Parameters for Pneumatic Control Valve in Abnormal Conditions (공기구동 제어밸브 비정상상태 운전변수에 관한 실험적 연구)

  • Kim, Yang-seok;Kim, Dae-woong;Lee, Byoung-oh;Jeoung, Rae-hyuk;Lee, Seung-ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.613-619
    • /
    • 2016
  • A pneumatic control valve performs a major role in controlling the flow of a system or the level of a key tank in many power plants, and its performance should be guaranteed during the plant's lifetime. Its operation starts by supplying air to the pneumatic actuator or by exhausting the air from the actuator. To control the valve position, the amount of air supply or exhaust is adjusted by a control loop where various accessaries are equipped. In this paper, air leakage in the air supply line, changes in the valve packing force, and false adjustments of zero and the span of the positioner are simulated and analyzed using a 2-in pneumatic valve with a position control loop including an I/P converter and positioner, where the valve position is controlled within ${\pm}2%$ of the control pressure at 67% opening position.

Development of Turbine By-pass Valves Control for the Hadong Power Plant Simulator (하동화력발전소 시뮬레이터 터빈바이페스밸브제어 개발)

  • 마삼선
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.10a
    • /
    • pp.46-46
    • /
    • 1999
  • 터빈 바이패스 밸브는 발전소의 사고시 발전기가 계통으로부터 분리될 때 터빈을 보호하기 위해 고온고압 에너지를 가진 증기를 안전하게 바이패스하여 발전소 신뢰도를 향상시키는 주요설비로써 신속하고 안전하게 제어가 되어야 한다. 이를 위해 증기온도 제어에 관측기를 가진 상태변수 제어기 등 고급제어가 사용되며 하동화력 시뮬레이터에 사용되는 터빈 바이패스 밸브제어의 개발과정을 서술한다. 디지털제어의 개발은 우선 제어모듈을 분석한 후 각 기능별 제어모듈을 개발하여 충분히 시험한 수 이것을 이용하여 제어로직을 모델링한다. 제어 모델링이 완료되면 발전소 다아나믹 모델과 연계를 위해 각 변수의 이출력(I/O)을 설정한다. I/O에 의해 제어로직과 발전소의 다이나믹 모델을 접속한 후 최종 튠닝(Turning)을 통하여 개발을 마무리하게 된다. 터빈 바이패스 밸브 바이패스 제어의 개발 의의를 살펴보면 각종 제어기능에 따른 모듈의 개발과 이의 적용을 통해서 실제 제어로직의 설계가 가능하며 또한 동적모델과 연계한 시뮬레이션을 통해 정확도를 높일 뿐만 아니라 확장된 제어의 개발도 가능하게 된다.

  • PDF

Development of Embedded Controller for Autonomous Tractor Steering System (자율주행 트랙터의 조향 시스템을 위한 임베디드 제어기 개발)

  • Lee, Hyeon Seung;Kim, Ki Duck;Lee, Young Ju;Hwang, Dong Yeol;Shin, Beom Soo
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.152-152
    • /
    • 2017
  • 본 연구에서는 비례제어밸브를 이용한 자율주행 트랙터 조향 시스템 제어를 위하여 저가의 임베디드 시스템을 사용한 제어기를 개발하였다. 차륜의 조향각 측정을 위하여 전륜 킹핀에 포텐시오미터를 설치하였으며, 비례제어밸브는 -10 ~ +10V의 전압으로 밸브 스풀의 위치제어를 수행하도록 하였다. 조향각 측정과 비례제어밸브의 위치제어를 위하여 각각에 AT90CAN128 AVR보드를 사용하였으며, CAN통신으로 조향각 데이터가 비례제어밸브 제어용 데이터로 전송될 수 있도록 하였다. 비례제어밸브 제어 보드에는 DAC기능을 추가하였으며 0 ~ 5V의 출력을 -10 ~ +10V의 전압으로 변환해 주는 인터페이스회로를 추가하였다. 일반적으로 GPS 등의 데이터 수신율이 20 Hz인 점을 감안하여 비례제어 밸브는 50 ms의 주기로 P-제어를 수행할 수 있도록 하였다. 향후 트랙터의 방향각을 설정하는 또 하나의 시스템으로부터 목표 조향각을 부여받는 것을 가상하여 별도의 MCU를 통해 목표 조향각을 송신한 후, 조향 유압실린더에 의한 전륜의 조향각 시간 응답 특성을 조사하였다. 실험은 트랙터의 전륜을 지면으로부터 들어올린 무 부하 상태에서 진행하였으며, 목표 조향각은 $7.5^{\circ}$, $15.0^{\circ}$, $22.5^{\circ}$ 등 3단계로 변경하며 시간응답 특성을 측정하였다. 최대 오버슈트 11%, 최소 오버슈트 8.6%, 정상상태 오차 약 $0.825^{\circ}$, 시정수(Time Constant)는 3단계의 목표 조향각 설정에서 각각 0.706초, 0.488초, 0.38초로 나타났다.

  • PDF