• Title/Summary/Keyword: 제습

Search Result 297, Processing Time 0.025 seconds

The Analysis of the Effects of Design Parameters on the Energy Efficiency and Performance of TEM Dehumidifiers (열전모듈 제습기의 에너지 효율과 성능에 미치는 설계 인자의 영향 분석)

  • Lee, Tae-Hee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2020
  • To provide a design direction for high efficiency thermoelectric module(TEM) dehumidifiers, the effects of design factors of TEM dehumidifiers on dehumidification energy efficiency and performance were numerically investigated. The design factors considered in this study are the TEM capacity, the performance of heat exchangers on the heating and cooling surfaces of the TEM. The higher capacity of the TEM results the higher dehumidification energy efficiency and performance at some operating voltage. The enhanced performance of the heat exchanger on heating surface increased the dehumidification energy efficiency and performance at all the operating voltage. The enhanced performance of the heat exchanger on cooling surface decreased the dehumidification energy efficiency and performance at all operating voltage.

Design of Automated Management System of Wardrobe using Humidity Sensor (습도 센서를 이용한 옷장 자동 관리 시스템의 설계)

  • Seo, Sang-Hyun;Jang, Si-Woong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.425-428
    • /
    • 2014
  • 기존의 옷장은 습도를 조절하려면 사용자가 스스로 습기와 냄새를 조절하기 위해 숯, 신문지, 선풍기 등의 보조적인 물품을 이용하여 습도 및 냄새를 제어하는 방식을 주로 사용한다. 집안의 습도를 조절하는 제습기, 냉장고나 화장실같이 습도가 높을 수밖에 없는 장소에 습도를 조절하기 위한 특수 제습제들이 출시되어 있다. 그중 옷장을 위한 보조 물품으로 여러 가지 제습제들이 개발되어 사용되고 있지만 여러 가지 불편한 점이 존재한다. 본 논문에서는 현재 시중에 제공되고 있는 옷, 냉장고보다 저렴하고 효율이 높은 옷장의 습도 자동화를 위해 습도 센서를 이용해 옷장안의 습도를 점검하고 직접 또는 원격으로 조절하는 효율적인 관리 방법을 알아보고 이를 통해 옷장의 습도 자동화에 따른 장점들을 종합하여 효율적인 옷장의 습도 조절 방법을 제시하였다.

  • PDF

Development Cooling and Dehumidifying System for Greenhouse using Hygroscopic properties of Lithium Bromide Solution (리튬브로마이드 수용액의 흡습성질을 이용한 온실 냉방 및 제습 시스템 개발)

  • Cho, La Hoon;Oh, Kwang Cheol;Lee, Sang Yeol;Joo, Sang Yeon;Park, Sun Yong;Lee, Seo Hyeon;Jeong, In Seon;Lee, Chung Geon;Kim, Dae Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.79-79
    • /
    • 2017
  • 국내 여름철의 고온다습한 기후환경으로 인하여 온실 내부의 냉방 및 제습이 필수적인데, 온실 냉방 방식 중 증발냉각 시스템이 가장 효율이 높다고 알려져 있다. 하지만 증발냉각 시스템은 건조한 기후 지역에서 발달한 방식으로, 작물의 증산작용으로 인한 온실 내부 습도 상승에 따른 문제점이 발생되어 다습한 여름철 국내 기후에는 반드시 냉각과 제습이 동시에 필요하다. 따라서 증발냉각 방식 중 Fan and Pad 방식과 리튬브로마이드 수용액을 이용한 온실 냉방 및 제습을 위한 복합시스템에 관한 연구가 진행중이다. 현재 리튬브로마이드 수용액 제습 시 발생되는 발열량과 수용액의 무게변화와 같은 수용액의 흡습성질 대한 정확한 지표가 나타나 있지 않다. 이에 연구를 진행하기에 앞서 리튬브로마이드 흡습성질에 관한 데이터 자료가 필요하다고 판단되어 기초실험을 진행하였고, 본 연구에서는 Pilot Scale의 재생 순환시스템을 통해 리튬브로마이드 수용액의 흡습성질을 이용한 재사용 방안을 제시하였고, 시스템 내에서 외부투입공기와 작동유체의 흡습성질에 의한 반응 전후 온도변화 예측 모델을 수립하였다. 따라서 본 연구를 통해 리튬브로마이드 수용액의 흡습성질을 분석하고, 이를 이 용한 재생 순환 시스템에 관한 연구를 진행할 예정이다.

  • PDF

Characteristic Analysis of Hybrid Desiccant Cooling System for District Heating in Residential Environment (지역난방에 연계된 하이브리드 제습냉방시스템의 주거환경에서의 성능 분석)

  • Ahn, Joon;Kim, Jaeyool;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.7
    • /
    • pp.571-579
    • /
    • 2014
  • A series of field tests on hybrid desiccant cooling systems were conducted in July-August, 2013. The temperature and humidity of the supply and return air, power, and heat consumption were monitored and transferred in real time through the Internet. The performance parameters of the cooling system, namely, cooling capacity and COP (coefficient of performance), were evaluated from the measured data and their variations under outdoor conditions was analyzed. It was found that with increase in the outdoor temperature, the total energy decreases and cooling capacity increases whereas the latter decreases with increase in the outdoor humidity. The COP was also found to increase with the increase in outdoor temperature.

The Effects of the Dehumidifying Membrane Dryer for the Curing Processes of Waterborne Adhesives (수용성 접착제 경화 공정용 제습 막 건조기 시스템의 효과)

  • Yu, Seoyoon;Lim, Choong-Sun;Seo, Bongkuk
    • Journal of Adhesion and Interface
    • /
    • v.17 no.2
    • /
    • pp.62-66
    • /
    • 2016
  • The curing processes of waterborne adhesives are in general undergone by using hot-air dryer. The hot-air dryer curing the adhesives with heat has a disadvantage of requiring high temperature over $100^{\circ}C$ as well as curing time as long as 20 min. When it comes to the heat control, high temperature open disturbs the adhesion of substrates by extremely lowering the viscosity of the adhesives. Furthermore, the humidity resulting from the drying process makes the curing condition irregularly. In this report, dehumidifying membrane dryer was used in order to keep the curing process same by removing humidity caused by the evaporation of water during the drying process, and to shorten the curing time. Here, we compared the peel strength of attached substrates in the dehumidifying membrane dryer to find out appropriate curing condition and confirm the effects of the dehumidifying membrane.

Performance Analysis of Hybrid Desiccant Chiller Based on Field Test (실증 실험을 통한 하이브리드 제습냉방 시스템의 성능 분석)

  • Ahn, Joon;Yun, Changho;Kang, Byung Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.7
    • /
    • pp.621-627
    • /
    • 2013
  • Field tests of hybrid desiccant cooling systems were conducted from July to August 2011. Data were monitored and transferred in real time over the Internet. The monitored variableswere analyzed to determine the performance characteristics under outdoor conditions. A series of system simulations has been conducted for outdoor conditions of the field tests. The results agree well with the experimental data in general. The system performance has been shown to deteriorate for wetter conditions, as predicted by the simulation.