• Title/Summary/Keyword: 제습효과

Search Result 29, Processing Time 0.022 seconds

A Study on Performance of Energy Recovery Ventilator under Outdoor Conditions in Korea (국내 외기조건에서 폐열회수 환기장치의 성능에 관한 연구)

  • Kim, Il-Gyoum;Park, Woo-Cheul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.52-57
    • /
    • 2009
  • In this study, a simulation program has been developed to predict the performance of energy recovery ventilators fur various indoor and outdoor conditions. In order to get a fundamental data about domestic air condition, the heat recovery ventilator is selected with the product of the wind quantity $250m^3/h$ Japanese M companies which are satisfied at High Efficiency Certification Standards. At the case on which the heat recovery ventilator is established, heating load decreases by 69.1% and cooling load decreases by 59.4% in Seoul, and heating load decreases by 66.4% and cooling load decreases by 59.6% in Pusan. The maximum humidification load of winter or summer time with $0.737{\ell}/h$ or $1.008{\ell}/h$ occurred in March from Kangnung or August from Mokpo respectively. In Southern part region and East Sea of winter time, the condensation or frost on exhaust side dose not occurred on exhaust side, but the area of that outside is occurred. Therefore, the preventive measure from the area except a southern part region and the east coast area must be considered, in order to condense or frost not to occur on exhaustion side in winter.

The Effects of Chitosan-Ascorbate Treated Kwamaegi on Serum Lipid Profiles and ROS-Related Enzyme Activities in Rats (키토산-아스코베이트 처리 과메기의 식이가 정상 흰쥐의 혈청지질과 항산화계 효소활성에 미치는 영향)

  • Kim, Do-Kyun;Kim, Jae-Won;Oh, Sung-Hee;Lee, Sang-Il;Kim, Mee-Jung;Kim, Soon-Dong
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.19 no.6
    • /
    • pp.987-995
    • /
    • 2009
  • The effects of Kwamaegi on serum lipid profiles and ROS(reactive oxygen spices) generating and scavenging enzyme activities were investigated in rats. The three experimental groups were divided as follows: normal control diet group (NC), 5% naturally prepared and freeze-dried Kwamaegi supplemented diet group (NPK) and 5% chitosan-ascorbate treated and artificially dried (CWDD: Chilly Wind & Dehumidification Drier) Kwamaegi supplemented diets group (CAK). There were no significant differences in weight gain, feed intake, feed efficiency ratio or organs weights per body weight including liver, kidney, heart and spleen among the group. In addition, there were no significant differences in serum triglyceride and total cholesterol contents. The HDL-cholesterol contents of the NC, CAK and NPK groups were 62.00, 36.48 and 78.44 mg/dL while LDL-cholesterol contents were 62.00, 36.48 and 78.44 mg/dL, respectively, which were significantly different. The atherogenic indeces in the experimental groups were 0.62, 1.20 and 0.13, respectively. There were no significant differences in total XOD (xanthine oxidoreductase) activities; however XOD type O activity was higher in the NPK group than un the NC group and in the CAK group XOD type O activity was 21~45% lower compared to NC and NPK groups. SOD (superoxide dismutase) activity was significantly higher in the CAK group than in the NC and NPK groups, while there were no significantly differences in GST (glutathione S-transferrase) activity among the groups. Furthermore, serum ALT activity was higher in the NPK group versus the NC and CAK groups. GSH (glutathione) content was higher and LPO (lipid peroxide) content lower in the CAK group compared to the NC and NPK groups. Forem the above results, we suggest that CA treated and artificially dried Kwamaegi is not only a hygienic product but also has lowering effects on LDL-cholesterol and the atherogenic index together with the lowering of ROS-generating and increasing of ROS-scavenging enzyme activities compared to other natural products.

  • PDF

Study on the Regenerating Performance of Liquid Desiccant in the Cooling/Dehumidification System able to use a Solar Water Heater in Summer(On the Analysis of Source Effect by the Design of Experiments) (여름철 냉방/제습시스템 중 태양열 온수기를 적용할 수 있는 액체흡수제의 재생성능에 관한 연구(실험계획법에 의한 요인효과 분석에 관하여))

  • Choi, K.H.;Kim, B.C.;Kim, B.J.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • With the possibility of hot water being able to be used as a heating source in a liquid desiccant system, an experimental apparatus for regeneration of the liquid desiccant was set up and series of experiments were conducted in a climate-controlled chamber. This study was performed to ascertain the influences of experimental factors on regenerating performance and to suggest the optimal combination of factors affecting regeneration rate. Furthermore. in order to figure out the contribution ratio of the factors on regenerating performance, a multi-way factorial design among the design of experiments was adopted. According to experimental results, the most influential factor on regenerating performance was temperature of the liquid desiccant and its contribution ratio was about 79.4%. In addition. the optimal operating combination was as follows; $60^{\circ}C$ of solution temperature, $14\ell$/min of solution flow rate, and 190m3/h of air volume.

Inhibitory effect of Smilacis Glabrae Rhizoma on nitric oxide production in the macrophage cell line RAW 264.7 (토복령(土茯笭)이 RAW264.7 대식세포주에서 산화질소 억제에 미치는 영향)

  • Lee, Kang-Hee;Jung, Jun-Hee;Kim, Ee-Hwa;Lee, Jae-Hyuk
    • Korean Journal of Acupuncture
    • /
    • v.26 no.3
    • /
    • pp.69-76
    • /
    • 2009
  • Objectives : 본 연구의 목적은 제습, 해독, 통리관절등의 효능이 있는 토복령이 RAW264.7 대식세포주에서 lipopolysaccharide(LPS)로 처치하여 생성되는 nitric oxide(NO)와 prostaglandin $E_2$($PGE_2$)에 억제작용이 있는지 관찰하고자 하는 것이다. Methods : 토복령이 RAW264.7 대식세포주에 세포독성이 유무를 관찰하기 위하여 농도별 MTT assay를 수행하여 세포생존율을 측정하였다. 또한 LPS로 염증유발된 RAW264.7 대식세포주에서 토복령의 농도별 처치가 NO 및 $PGE_2$ 생성억제에 미치는 영향을 관찰하고자 NO 및 $PGE_2$ assay를 수행하였다. Results : 토복령의 농도별 처치가 RAW264.7 대식세포주에서 세포독성을 유발하는지 MTT assay로 측정한 결과 세포독성은 관찰되지 않았으며, 토복령은 LPS처치로 인하여 증가된 NO 및 $PGE_2$ 생성을 통계학적으로 유의하게 감소시킴을 관찰하였다. Conclusions : 본 연구를 통하여 토복령은 RAW264.7 대식세포주에서 LPS로 유도된NO 및 $PGE_2$ 생성을 효과적으로 억제시킴으로써 추후 염증질환의 치료제로서 가능성을 확인하였다.

  • PDF

Electroosmotic Water Removal in Wet Porous Materials (다공성 흡수매체에 대한 정전삼투 탈수효과)

  • Park, Seon-Mi;Park, Mi-Jung;Ha, Ji-Soo;Chang, Hyuk-Sang
    • Clean Technology
    • /
    • v.16 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Various technical methods are applied for removing water from the water-retaining media, and the energy efficiency is the main concern in those methods. The electroosmotic process is studied as an efficient way for dewatering. An experimental electroosmotic reactor is designed and used for evaluating the effects of operational variables. The operational variables such as the electrical fields and the structure of water-retaining medias were studied. Three different shapes of polarized electric fields in ranges of 0-100 V/cm and 0-10 kHz are used as the source of electric voltage. The effect of electroosmotic process with respect to the structural variation is estimated by filling the electroosmotic reactor with the glass beads in 0.18 mm, 0.35 mm and 1.2 mm in diameters. 6% of water removal is obtained in the simulating electroosmotic reactor of glass beads. The estimated energy consumption in the simulating electroosmotic was 330~490 cal/g-water.

The Anti-obesity Effect of Seungyangjeseup-tang for High Fat Diet Induced Obese Mice (고지방식이 유도 비만 생쥐에 대한 승양제습탕의 항비만 효과)

  • Kim, Jung-Min;Choi, Soo-Min;Woo, Chang-Hoon;Ahn, Hee-Duk
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.3
    • /
    • pp.1-11
    • /
    • 2018
  • Objectives This study was designed to evaluate the efficacy of Seungyangjeseup-tang on obesity by using 3T3-L1 cells and high fat diet mice. Methods In vitro, Seungyangjeseup-tang extract (SYJST) (10, 50, 100, 200, 400, $800{\mu}g/mL$) ware added in 3T3-L1 cells. SYJST cytotoxicity was measured by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assasy. Adipocyte differentiation was measured by Oil Red-O staining. In vivo, the experimental animals were divided into five groups: normal diet-fed normal group (N), high-fat diet (HFD)-fed control group (Con), HFD+SYJST 100 mg/kg group (SY100), HFD+SYJST 200 mg/kg group (SY200), and HFD+olistat 60 mg/kg as a positive drug control group (Orli). Markers of obesity, such as body weight, liver weight, food intake, serum total cholesterol (TC), triglycerides (TG), high density lipoprotein cholesterol (HDL-C), liver tissue TC, TG and fecal TC, TG were measured. Results In vitro, cytotoxicity was not significant compared with the control group. 3T3-L1 cell's differentiation was significantly decreased in Oil Red-O staining. In vivo, compared with controls, mice treated with SYJST demonstrate lower body and liver weight, and reduced food intake. In addition, SYJST increased TC, TG in the serum but not significance. And SYJST showed decreasing tendency TC, TG in the liver tissue. Furthermore, SYJST increased TC, TG in the facal but not significance. Conclusions Based on the results above, Seungyangjeseup-tang may reduce adipocyte differentiation, body fat, food intake, liver weight in obesity. This suggests that Seungyangjeseup-tang may be clinically useful in obesity treatment.

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015 (설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.