• 제목/요약/키워드: 제습시스템

검색결과 102건 처리시간 0.025초

A Study on Dehumidification Characteristics of Housing with Shape for Pneumatic System (공압시스템 제습용 중공사막 모듈의 하우징 형태에 따른 제습효율 특성 연구)

  • Jeong, Eun-A;Lee, Kee-Yoon;Yun, So-Nam
    • Journal of Drive and Control
    • /
    • 제16권2호
    • /
    • pp.66-71
    • /
    • 2019
  • In this study, flow analysis and dehumidification experiments were performed on hollow fiber membrane module to confirm the dehumidification characteristics for its different configurations. The CFD for the three different models was conducted using $30^{\circ}C$ temperature and 30%RH inlet humidity for quantitative analysis. Each model has different shape parameters i.e. the number of baffles. Comparison between flow analysis results and dehumidification experiment results revealed a percentage error of about 5%. The difference in relative humidity between the inlet and outlet for each model was calculated using flow analysis data. It was established that the difference in relative humidity of the inlet and outlet for the refined model with three baffles was highest among the three modeled modules of hollow fiber membrane module, i.e. around 9%.

Study on the Performance Characteristics with the Height of a Regenerator and Dehumidifier for Liquid Desiccant Dehumidification System (액체식 제습시스템을 위한 재생기와 제습기의 높이에 따른 성능특성에 관한 연구)

  • 이수동;박문수;정진은;최영석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • 제16권7호
    • /
    • pp.630-638
    • /
    • 2004
  • Liquid desiccant dehumidification systems have the ability to provide efficient humidity and temperature control while saving the electrical energy requirement for air conditioning as compared to a conventional system. The dehumidifier and the regenerator form the heart of this system. The latent part of the cooling load is overcome using liquid desiccant. The model regenerator has been designed to study the absorption characteristic of the aqueous triethylene glycol (TEG) solution which is in the flow range from 20 to 50 LPM. Also, this system designed that was able to change the height of the regenerator and dehumidifier. Because the effect of performance have different result according the height. The effect of performance factors of the regenerator with inlet solution flow rate, air flow rate, solution concentration, solution temperature, brine temperature, air temperature and inlet air relative humidity have been analyzed. Data obtained are useful for design guidance and performance analysis of the hybrid air conditioning system.

Developing Trend of Gas Separation Membrane for Dehumidification (제습용 기체분리막 개발동향)

  • Koh, Hyungchul;Lee, Choongsup;Ha, Seong Yong;Choi, Whee Moon;Rhim, Jiwon;Nam, Sangyong
    • Prospectives of Industrial Chemistry
    • /
    • 제14권3호
    • /
    • pp.25-36
    • /
    • 2011
  • 압축공기 중의 수분은 공압설비의 모든 요소에 중대한 해를 입히며 밸브의 고착, 계기의 막힘 또는 공압기기의 오작동을 일으키며 생산하는 제품의 질에 있어서도 많은 해를 입혀서 제품의 질을 떨어뜨리는 역할을 하게 된다. 따라서 수분을 제거하는 방법이 필요하며 기존의 냉동식 및 흡착식을 대신하여 분리막 법이 적용될 수 있다. 현재 제습용 기체분리막 모듈은 적용이 시작된 단계에 있다. 제습용 기체분리막은 의료기기, 분석기기, Instrument air 장비에 응용이 진행되고 있다. 최근 들어 선진각국 뿐만 아니라 국내에서도 막소재 개발, 복합막 개발, 모듈 개발, 시스템 설계 및 제작 기술 개발이 진행되고 있다. 현재로서는 제습막공정에 적합한 막소재의 개발이 시급하지만 이후 적용확대를 위해서는 제습용 기체분리막의 신뢰성 향상을 위한 다각도의 노력이 필요하다.

A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions (재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구)

  • Lee, Jang Il;Hong, Seok Min;Byun, Jae Ki;Choi, Young Don;Lee, Dae Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제38권5호
    • /
    • pp.413-421
    • /
    • 2014
  • Desiccant cooling system is an air conditioning system that uses evaporative cooler to cool air and it can perform cooling by using heat energy only without electrically charged cooler. Thus, it can solve many problems of present cooling system including the destruction of ozone layer due to the use of CFC[chloro fluoro carbon] affiliated refrigerants and increase of peak power during summer season. In this study, cooling performance and exergy analysis was conducted in order to increase efficiency of desiccant cooling system. Especially, using exergy analysis based on the second law of thermodynamics can resolve the issue related to system efficiency in a more fundamental way by analyzing the cause of exergy destruction both in whole system and each component. The purpose of this study is to evaluate COP[coefficient of performance], cooling capacity and exergy performance of desiccant cooling system incorporating a regenerative evaporative cooler in various regeneration temperature and outdoor air conditions.

Study on the performance of a heat pump system with serial dehumidification function (직렬 제습방식 열펌프 시스템의 성능특성에 관한 연구)

  • Ko, Wonbin;Ko, Ji-Woon;Park, Youn Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.609-614
    • /
    • 2014
  • In this research, results of measuring temperature and relative humidity of underground-air-heat in Jeju showed $15{\sim}18^{\circ}C$ and 70~80% each which are somewhat high compare to other regions. So the Multi-effect dehumidifying and heating Heat Pump system which has merged functions of dehumidification and heating is made to solve this problem mentioned previously. When the suction air was $15^{\circ}C$ with 60% humidity, the outcome was 1.70 on $COP_h$ and 1.797(kg/h) on total amount of dehumidification, and also showed 1.87 $COP_h$ with 1.87 total amount of dehumidification under the condition of $20^{\circ}C$ and 80% humidity of suction air. Furthermore, $COP_h$ showed increased number which is 1.87 and also total amount of dehumidification increased which was 3.269(kg/h). The highest COP can be achieved at $17^{\circ}C$ and 70% relative humidity condition.

Research on Heat and Mass Transfer Coefficient in the Packing Layer With a Solar Desiccant Heating/Cooling System (태양열 데시컨트 냉난방시스템 중 충진층에 있어서의 열 물질전달에 관한 연구)

  • Yohana, Eflita;Choi, Kwang-Hwan;Kim, Bu-Ahn;Kim, Dong-Gyu;Paek, Ki-Dong;Kim, Ji-Won
    • Journal of the Korean Solar Energy Society
    • /
    • 제26권3호
    • /
    • pp.17-24
    • /
    • 2006
  • 최근에 에너지절약 차원에서 종래의 공조방식을 대신할 새로운 냉난방시스템 개발이 요구되고 있는데, 본 논문에서는 태양열 집열기를 이용하는 데시컨트 시스템 중 제습역할을 실질적으로 담당하는 제습기의 충진층 부분에서의 열 및 물질전달에 관한 일련의 해석 결과를 발표하고 있다. 제습과정에서 액체흡수제는 충진층에서 열 뿐만 아니라 물질전달을 수반하게 되는데, 이 결과 건물에 냉방 및 난방효과를 가져다 준다. 따라서 이 충진층의 최적 설계가시스템의 효율을 극대화하기 위해서는 무엇보다도 중요한데, 이를 위해서는 충진층에서의 열 및 물질전달 양상을 규명하여야 한다. 따라서 금번 실험에서는 공기와 액체흡수제와의 접촉면적을 넓히기 위해서 충진재로써 3cm(직경) ${\times}$ 3cm(높이)인 시판중인 플라스틱 재질을 사용하고, 실질적으로 40cm(너비)${\sim}$40cm(깊이)${\times}$40cm(높이)의 충진층을 직접 제작하여 실험을 행하였다. 그 결과, 공기측 열 및 물질전달 계수는 공기 온도와 밀접한 관계를 갖고 있으며, 또한 물질전달계수는 열전달계수와 같은 경향을 보이고 있음을 알 수 있었다.

R&D Trend in desiccant based dehumidification and hybrid cooling system (건조제(desiccant)를 이용한 제습 및 복합냉방 시스템의 기술개발동향)

  • 박문수
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • 제27권6호
    • /
    • pp.533-540
    • /
    • 1998
  • 최근에 국내외 에너지 이용 효율성 증대 문제, CFCs등으로 인한 오존층 파괴문제, $CO_2$ 등으로 인한 지구온난화 문제, 실내공기질(IAQ)과 관련된 건물 환기량 증대요구로 인한 건물용 공조시스템(HVAC)의 설계변경 문제 등으로 인해 다양한 종류의 대체 냉방기기가 연구되어 오고 있다. 현재 미국에서는 ASHRAE Standard 62-1989에 의해 실내거주자의 필요한 IAQ와 쾌적함을 유지하기 위해 환기량을 기존의 경우보다 약 3배 이상이 되도록 권장하고 있고 또한 대다수의 미국 주 정부에서 건물설계에 관련된 조례로 ASHRAE Standard 62-1989를 적용하고 있다. 따라서 빌딩공조 설비관계자들은 늘어난 환기 요구량에 따라 잠열냉방용량이 크게 증대되므로 이를 처리하기 위한 새로운 냉방공조기기 시스템기술에 대해 관심이 증대하고 있다. 이에 따라 건조제를 x이용한 냉방 및 제습 시스템이 대체 냉방시스템 또는 기존의 냉방 시스템과 더불어 잠열부하를 처리하는 복합 시스템으로 최근에 다시 상당한 주목을 받고 있다.

  • PDF