• Title/Summary/Keyword: 정화조

Search Result 101, Processing Time 0.029 seconds

Nightsoil Treatment: Temperature Effects on Anaerobic Digestion (분뇨처리(糞尿處理) : 혐기성소화(嫌氣性消化) 온도영향(溫度影響))

  • Choi, Eui So;Lee, Byung Hun;Lee, Chan Ki
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.3
    • /
    • pp.23-32
    • /
    • 1982
  • This study was conducted to evaluate the temperature effects on the nightsoil, anaerobic digestion, whether it could be operated with a higher organic loading rate at a higher temperature during summer months, or with a lower organic loading rate at a lower temperature during winter months. A laboratory completely mixed digester was continuously operated at 11 different temperatures from $18.5^{\circ}$ to $60^{\circ}C$ with 30 days of HRT. The study results indicated that the best efficiency occurred at a temperature range of $35^{\circ}$ to $40^{\circ}C$, at which BOD and VS removal efficiencies were respectively 71 and 53 percent, and gas production rate was $0.6m^3/kg$ VS fed or $16m^3/m^3$ fed. BOD removal efficiency would be increased to 78 percent if the digester effluent settled for 24 hours. Since the digester efficiency decreased beyond this temperature range, this suggested the digester need not to operate a higher temperature even during the summer months. The laboratory results were in good agreement with those of the existing digester operated at a temperature range of $32^{\circ}$ to $40^{\circ}C$. Application of septage or cow manure to the digester with nights oil at a rate of 1 to 1 did not greatly affect the digester performances. In addition, the digester effluent could be treated aerobically without any dillution water. BOD and SS removal efficiencies were greater than 90 percent in this case.

  • PDF

하천 오염현황과 대책

  • 이은호
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1979.10a
    • /
    • pp.234-236
    • /
    • 1979
  • 인구의 도시집중과 고도산업사회 건설에 필연적으로 수반되는 도시하수 및 산업폐수등은 하천을 심각하게 오염시켜 하천수가 지니고 있는 자정능력 한계를 초과하고 있어 재생될수 없는 상태이므로 수자원의 보호가 요청된다. 이런 상황의 하천오염 증가 추세와 주요 오염원 및 오염물에 대하여 고찰하고 대책에 방향을 제시한다. 먼저 전국의 급수 현황과 장래를 보면 다음과 같다. 한편 수도권 한강수계를 오염시키는 주요 오염원인 폐수를 보면 주거지의 생활하수, 상업행위로 발생되는 폐수와 공장의 산업폐수로 대별할 수 있으며 수도권 한강에 유입 되는 지천 수질을 보면 다음과 같다. 위와 같은 상태의 총폐수량은 280만톤인데 비하여 청계, 중량하수처리장과 서부 북부 동부분뇨처리장의 일일 처리능력은 16.4%에 불과하다. 한편 서울지역 오염원구성비를 보면 다음과 같다. 이런 계속적인 오염물은 1977년 경우 갈수기에 80~100t/sec의 하천유량으로 희석되고 있어 자정능력 한계를 벗어나서 하류의 물은 혼탁하고 용존산소의 고갈현상을 초래하고 있다. 그러므로 도시 하천에서는 수류침체로 인한 하상퇴적을 방지하여 국소적 오염의 심화를 방지하며 유량을 증가 시켜야 한다. 수도권 한강 수계의 수질의 일부는 다음과 같다. 한편 생활수준의 향상과 더불어 수요가 급증되며 처리장의 효율과 하천수의 수질을 악화시키는 합성세제의 총생산량은 1971년에 21000톤이던 것이 1978년에는 약 50,000톤에 이르고 있으며 이중 55~60%가 서울지역에서 소모되는 것으로 추산되어 진다' 결과 한강수에서 검출되는 합성세제의 오염 현황을 보면 다음과 같이 이미 몇개 지점에서는 세계 보건기구의 허용량인 0.5ppm을 초과 하고 있는 실정이다. 또한 오염의 연쇄현상을 나타내는 중금속의 일종인 csduium의 검출 정도를 보면 다음과 같다. 이상의 하천오염에 따른 수중생태계의 변화는 물리적 화학적 생물학적 환경요인이 복합적으로 작용하는 세부적 기계에 대하여는 규명되지 않은 문제가 아직도 많으며 지표생물의 표현형은 중요한 가치를 부여하고 있다. 식물성 plankton의 우점종의 출현 빈도에 따른 수질계급을 보면 뚝섬지역 BOD 3.3~5.3 빈부수성 $~\alpha$ 중부수성, 보광동 BOD 6.0~10.3중부수성, 제 2한강교 BOD10~28 $\alpha$ 강부수성, 난지도 BOD29 $\beta$ 강부수성 등이며 이와 상이한 결과도 보여주고 있다. 이상으로 볼 때 1) 가정하수의 질을 높이기 위하여 분뇨정화조 의 효율증대 2) 산업폐수의 공정별 폐수량의 조절 및 폐수성 상에 따른 총량규제에 대비한 효율증대 3) 하천의 오염부하와 자정능력 최대한 부여 4) 폐수처리를 위한 미생물제개발 및 오염지표 종 연구와 오염내성 생물의 연구등이 종합적 으로 수행되어야 한다. 5) 이상의 모든 조사와 연구결과를 객관적으로 표기할 수 있도록 하천의 이정표가 정해져야 하겠다.

  • PDF

Generation and Current Treatment Status of Sewage at the Rural Village in Chungnam Province (충남지역 마을하수의 발생 및 처리현황)

  • Kang, Bang-Hun;Kim, Jin-Ho;Choi, Chul-Mann
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2008
  • The purpose of this study is to investigate the current status, including the maintenance problems and removal efficiency, of small sewage treatment facilities in Chung-nam province(Asan, Buyeo, and Gongju city). Our results showed that inflow water quality of Asan city was 19.1 mg/L of BOD, 29.0 mg/L of COD, 13.4 mg/L of T-N and 1.5 mg/L of T-P, respectively, which was much higher than any other site. Among the factors known to be an important index of water quality, the SS and BOD removal efficiency was about 70% and 50% respectively. However, the nitrogen removal efficiency was less than 10%. The total removal efficiency of pollutant was 71.1% of SS, 52.6% of BOD, 46.2% of COD, 9.2% of T-P and 4.6% of T-N respectively. Therefore nitrogen removal processes are required to prevent serious eutrophication of small river. Removal efficiency for BOD and SS of high-efficient sewage treatment facilities (STFs) and contact oxidation process was much higher than another process. Performance of these sewage treatment facilities(STFs) is not optimal due to ineffective planning for the inflow water quality. To improve these facilities, it is proposed that a technical expert analysis of water quality at these facilities is periodically required.

Effect of Non-Agricultural Facilities on Water Quality and Contamination in Rural Area (농촌용수 수질관리를 위한 비농업시설의 영향 연구)

  • Lee, Byung-Sun;Um, Jae-Yeon;Kim, Yang-Bin;Woo, Nam-Chil;Nam, Kyoung-Phile;Lee, Jong-Min
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.1-9
    • /
    • 2009
  • This study was objected to identify the effect on water quality and contamination by non-agricultural facilities in 'A' reservoir watershed located in OO city, Kyounggi-do, Korea. Ground- and stream water samples showed (Na+K)-Cl, Ca(Cl, SO$_4$) and Ca-Cl type in an illegally discharging area of sewage and a densely industrial area indicating water contamination. Stream water of an illegally discharging area of sewage had high COD, T-N and T-P. In this area, direct incoming of sewage into stream water was induced ground water system by well pumping, and it made a progress of ground water contaminations with those components. Groundwater of a densely industrial area showed high concentrations of T-N, NO$_3$N. From a nitrogen isotope analysis, stream water of an illegally discharging area of sewage has ${\delta}^{15}N-NO_3$values of 0.7%0 was strongly affected by nitrogen originated from agrochemicals, and a densely industrial area of 19.7%0 from septic system. Ground- and stream water of a livestock fanning area were contaminated with NH$_3$-N and Mn, which was affected by intensive livestock facilities. SAR-conductivity plot indicates the water does not pose either alkalinity or salinity hazard for irrigation. COD, T-N, T-P, NO$3$-N, NH$_3$N and Mn concentrations from contaminated areas were diminished by mixing with 'A' reservoir water. There were no water contaminations in silver towns, vacationlands around reservoir and golf links. Consequently, it should be made a plan of systematic managements for past and- present possible contaminants and sewage systems in preventing water contamination by non-agricultural facilities.

Hydrochemistry and Nitrogen and Sulfur Isotopes of Emergency-use Groundwater in Daeieon City (대전지역 민방위 비상급수용 지하수에 대한 수리화학과 질소 및 황 동위원소 연구)

  • 정찬호
    • The Journal of Engineering Geology
    • /
    • v.13 no.2
    • /
    • pp.239-256
    • /
    • 2003
  • The purpose of this study is to investigate the hydrochemical characteristics of emergency-use groundwater in the Daejeon area, and to elucidate the contamination source of $NO_3-N$ and the origin of sulfate in the groundwater. The groundwater shows weak acidic pH, the electrical conductivity ranging from 142 to $903{\;}\mu\textrm{S}/cm$, and the hydrochemical types of $Ca-HCo_3$ and $Ca-Cl(SO_4,{\;}NO_3)$. The Box-Whisker analysis and the Krigging analysis of chemical data of groundwater were made to demonstrate the concentration distribution of hydrochemical composition, and to compare the trend of hydrochemical data. The groundwater in the area of Dong-gu, Jung-gu and Daeduk-gu, where are old town, shows higher electrical conductivity, nitrate content, sulfate and $EpCO_2$ levels than groundwater in new town area of Seo-gu and Yusung-gu. ${\delta}^{15}N$ of groundwater in the area of Seo-gu and Yusung-gu ranges from +7.4 to $+9.6{\textperthousand}$, indicating that major contamination source of $NO_3-N$ is the leakage from municipal sewage pipe lines. ${\delta}^{15}N$ of groundwater in the old town area of Tong-gu, Jung-gu and Daeduk-gu shows the range between +10.2 and $+23.5{\textperthousand}$, meaning that major contamination source is leakage of septic tank. ${\delta}^{34}S$ of groundwater shows the range of $+3~13.4{\;}{\textperthousand}$. Sulfur isotope indicates the possibility of a sulfate reduction and the input of anthrophogenic source.

Studies on Deacidification of Citrus Fruit and Juice for Juice Products by Heating Treatment and Electrodialysis (열처리 및 전기투석에 의한 초기수확 밀감의 탈산에 관한 연구)

  • Ko Won-Joon;Yang Min-Ho;Kang Yeung-Joo
    • Food Science and Preservation
    • /
    • v.13 no.2
    • /
    • pp.144-153
    • /
    • 2006
  • The effects on deacidification of citrus fruits produced at early harvesting season for juice products were examined by heating treatment of raw fruits and electrodialysis of juice. Weight and total acidities were decreased by heating treatment for 40 hr at $25^{\circ}C,\;30^{\circ}C,\;35^{\circ}C\;and\;40^{\circ}C$, but $^{\circ}Brix$ and pH increased Sugar to acid ratio also increased. Total acidities were decreased from 1.25 (Oct30, 2004), 1.24 (Nov.5, 2004), 0.99 (Nov.13, 2004) and 0.98% (Nov.19, 2004) to 0.48 (Oct30, 2004), 0.51 (Nov.05, 2004), 0.37 (Nov.13, 2004) and 0.42% (Nov.19, 2004) by electrodialysis for 100 min respectively, and $^{\circ}Brix$ also slightly decreased, but solid to acid ratio was increased as a result. However pH and color remained almost unchanged by electodialysis. Also, free sugar contents of citrus juice little were changed, but organic acid content were decreased fairly. Narirutin and hesperidin content among flavonoids were slightly decreased by electrodialysis, but they were not significantly different. $K^+,\;PO_4^{2-},\;SO_4^{2-}\;and\;Cl^-$ content were decreased by electrodialysis, and $K^+$ contents decreased by more than 80% However, $Na^+$ consent was increased by about 2 times. Total polyphenol contents and electron donating abilities were decreased a little by electrodialysis but nitrite scavenging abilities were little changed. By acceptability test citrus juice prepared by electrodialysis for 100 min was superior to original citrus juice.

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

A Study on Medical Waste Contaminated by Radioactivity in Nuclear Medicine Department (핵의학과 일반 의료폐기물에서의 방사능 오염에 관한 고찰)

  • Yoo, Jae-Sook;Jang, Jung-Chan;Lee, Dong-Hoon;Cha, Min-Kyeong;Nam, Ki-Pyo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.70-74
    • /
    • 2011
  • Purpose: In the Nuclear Medicine department of Asan Medical Center, radioactive waste has been disposed of by using several disposal boxes designed for nuclear waste. However, some quantity of radioactivity has been detected occasionally due to some radiologists' carelessness not only from radioactive waste, but also from medical waste such as uncontrolled radioactive waste related to patients, poly gloves or saline solution bottles from radiopharmaceuticals laboratory. Thus, this study is going to suggest a solution to maintain the medical wastes made from controlled areas that can be below maximum permissible surface dose limits by finding the cause of radioactive contamination. Materials and methods: This study was taken place in 17 different places-2 medical wastebaskets in the waiting room, 2 medical wastebaskets in the PET room, 5 medical wastebaskets in the in vitro laboratory and 6 medical wastebaskets in the radiopharmaceuticals laboratory of the East building, 2 medical wastebaskets in the waiting room of the New building of Nuclear Medicine Department in Asan Medical Center from April to August 2010. Mean radioactivity and its standard deviation of each place have been found by measuring surface contamination of medical wastebaskets and backgrounds twice a week, totaling 30 times. An independent t-test of SPSS (Ver. 12.0) statistic program has been used for statistical analysis. Swabs, saline solution bottles and poly gloves collected from each place also measured 30 times, respectively. Results: This study analyzed medical waste and the backgrounds of each place by using survey meter detectors that significant differences of five places did not exist, but existed statistically in twelve places (p<0.05). Also, swabs, saline solution bottles and poly gloves collected from each radioactive waste partly exceed the legal dose limit as a result of measuring by a gamma counter. Conclusion: Backgrounds and the surface doses of radioactive disposal box in all 17 places measured by the survey meter did not exceed the legal dose limit; however, it obviously showed that there were prominent differences in 12 places. Assuming that the cause of the differences was swabs, saline solution bottles and gloves, we examined them by gamma counter, and the results showed remarkably high doses of radioactivity. Consequently, swabs and poly gloves which are normally disposed in the general medical waste box should be disposed in the radioactive waste box furnished by radiopharmaceuticals laboratory. Also, saline solution discharged from radioactive pharmaceutical places is considered as radioactive liquid waste so that it should be disposed of by the septic tank specifically designed for radioactive liquid.

  • PDF

Treatment Level of a Pond System for Ecological Treatment and Recycling of Animal Excreta (생태적 축산폐수 처리 및 재활용 연못시스템의 폐수처리수준)

  • Yang, Hong-Mo;Rhee, Chong-Ouk
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.1
    • /
    • pp.70-75
    • /
    • 1998
  • A model of pond system is developed for treatment and recycling of excreta from twenty-five adult dairy cattle. It is composed of wastewater treatment ponds and small fish ponds. Those are three facultative ponds in series; primary-secondary-tertiary pond and these are designed to rear carps without feeding. A pit is constructed at the bottom of primary pond for efficient sludge sedimentation and effective methane fermentation. It is contrived to block into it the penetration of oxygen dissolved in the upper layer of pond water. The excreta from the cattle housed in stalls are diluted by water used for clearing them. The washed excreta flow into the pit. The average yearly $BOD_5$ concentration of influent is 398.7mg/l. That of the effluent from primary, secondary and tertiary pond of the system is 49.18, 27.9, and 19.8.mg/l respectively. Approximate 88, 93, and 95 % of BOD5 are removed in each pond. The mean yearly SS concentration of influent is 360.5 mg/l That of the effluent from each pond is 53.4, 45.7, and32.7mg/l respectively. Approximate 86, 88, and 91% of SS are removed in each pond. The $BOD_5$ concentration of secondary and tertiary pond can satisfy 30mg/l secondary treatment standard. The SS concentration of effluent from tertiary pond, however, is slightly greater than the standard, which results from activities of carps growing in the pond. The average yearly total nitrogen concentration of influent is 206.8mg/l and that of the effluent from each pond is 48.6, 30.8, and 21.0mg/l respectively. Approximate 74, 88, and 90% of total nitrogen are removed in each pond. The mean yearly total phosphorous concentration of influent is 20.7mg/l and that of the effluent from each pond is 5.3, 3.2, and 2.1mg/l respectively. Approximate 97, 98, and 99% of total phosphorous are removed in each pond. The high removal of nitrogen and phosphorous results from active growth of algae in the upper layer of pond water. Important pond design parameters for southern part of Korea -- areal loading of BOD5, liquid depth, hydraulic detention time, free board, and pond arrangement -- are taken up.

  • PDF

Analysis of Relationship between Spatial Distribution of Land Use and Water Quality in Agricultural Reservoirs (토지이용의 공간적 분포와 농업용저수지 수질 간의 상관분석)

  • Lee, Sae-Bom;Yoon, Chun-Gyeong;Jung, Kwang-Wook;Jang, Jae-Ho;Jeon, Ji-Hong
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.3
    • /
    • pp.481-488
    • /
    • 2007
  • This study covers the relationship between land use and water quality items. The kinds of land used in this study were almost agricultural areas with paddy fields and mountains. We set up zones at intervals of 200 m along 48 watersheds all over the country. The analysis showed high relationship between the water quality and the land use specially on the areas in the 400 m radius from the stream so that the areas needed to have strict managements. In the cases of residential area and upland, the positive correlation had a tendency to be lower when they were farther away from the stream. It depended on the increase of rainfall during July and August which affected on the water quality of reservoirs. The correlation analysis of paddy fields resulted in negative relationship, which indicated that paddy fields did not have negative effect on the quality of the stream. Through adequate irrigation and Management, paddy fields may be led to have positive effect on the quality of the reservoirs. In the case of forest, it also resulted in negative correlation so it was concerned as a positive factor which helped to improve water quality. Furthermore more than 00% of the land used in this study is comprised of forest so that it would have a positive effect on the reservoir management.