• Title/Summary/Keyword: 정지용의 시

Search Result 141, Processing Time 0.03 seconds

Configuration and Characteristics of Fine Sun Sensor for Satellite (위성용 고정밀 태양센서 구성 및 특성)

  • Kim, Yong-Bok;Pank, Keun-Joo;Choi, Hong-Taek
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.87-93
    • /
    • 2011
  • FSSA(Fine Sun Sensor Assembly) is the important sensor for satellite attitude control. FSSA measures the direction of the sun's rays and determines whether the satellite is in the eclipse or not. FSSA for GEO Satellite is also used to acquire the attitude error information in the attitude control reference frame and acquire the Sun direction during transfer orbit or mission Process. This paper shows the configuration of Fine Sun Sensor for LEO and GEO Satellite and their principle of operation that angle measurement is obtained by using the transfer function which is the ratio of the difference between output currents of Solar Cell to the sum of all output currents.

A study on collision detection of industrial robots using the mechanical inertia observer (관성 관측기를 이용한 산업용 로봇의 충돌감지에 관한 연구)

  • Choi, Chi-Hwan;Shin, Soo-Cheol;Lee, Hee-Jun;Kim, Young-Real;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.11a
    • /
    • pp.65-66
    • /
    • 2012
  • 최근 많은 산업분야에서 로봇이 사용되고 있으며, 로봇을 산업 공정에 적용시키기 위해서는 인간의 협업이 반드시 필요하다. 또한 사람의 안전은 무엇보다 중요하기 때문에, 사람과 로봇이 충돌시 로봇이 정지되는 기능은 반드시 필요하다. 그러므로, 본 논문에서는 추정된 관성과 속도 변화량에 의해 계산된 기계적 토크와, q축 전류에 의해 계산된 전기적 토크를 비교하여 로봇이 사람이나 물체에 충돌시 이를 감지하고, 속도 지령을 감소 시킴으로써 로봇이 정지 하는 기능을 시뮬레이션과 실험을 통하여 검증 하였다.

  • PDF

영광 3,4호기 원자로 제어봉 제어계통 설계내용 분석

  • 김선호;윤원영;조항윤
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.521-525
    • /
    • 1996
  • 국내 최초 운전경험을 갖는 CE 형 원전 설계인 영광 원자력 발전소 3,4호기의 제어봉 제어구동 설비는 시운전 시험 과정 중 제어봉 제어용 전원설비의 전기적 잡음에 의해 일부 제어봉이 미끄러짐으로서 원자로가 계속적으로 불시정지 되었다. 이와 같은 현상으로 이미 국내에서도 가동중인 고리 원자력 발전소 2호기에서도 고주파 용접기의 전도성 잡음에 의하여 제어봉 제어회로에 영향을 주어 여러차례 원자로 정지를 겪은바 있다. 따라서 원자력 안전기술원에서 제어봉 미끄러짐의 원인을 조사결과 직접적인 원인은 제어봉 전원공급 설비에서 발생된 전기적 잡음에 의해 제어봉 제어회로의 오동작 및 발전소 부하탈락 시험시 소내전원 주파수 상승으로 제어봉 코일에 정격이하의 저전압이 공급됨으로서 원자로가 불시 정지 됨을 확인 하였다.

  • PDF

The Multipactor Test results on the X Band filter of Space Qualification Model appropriated for the Geostationary Satellite considering for space environments (우주환경을 고려한 정지궤도위성에 적합한 X대역 필터의 멀티팩터 시험 결과 연구)

  • Park, Jong-hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.65-68
    • /
    • 2017
  • In this paper, a multipactor test for the space qualification model of the X-band dual-mode high-power channel filter for high-speed data transmission of geostationary satellite observation payloads was conducted and compared with the 8 dB margin required for design. It was confirmed that analytically required margins were met through testing and that satisfactory test results were obtained. The design and test of the multipactor are tested according to the ECSS standard. Based on this, it is suggested that if the margin of design is sufficiently secured, it can be used in the development of the filter for space qualification model without any test.

  • PDF

SECURE, 지역난방용원자로

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • no.9_10 s.9
    • /
    • pp.38-40
    • /
    • 1982
  • 스웨덴의 원자로 marker Asea-Atom사는 지역난방(DH)용 원자로로 SECURE를 개발했다. 이 원자로는 (1) 저온도, 저압력, (2) 본질적인 안전성(기술적 안전시스템에 의하지 않은)에 의해 로의 정지${\cdot}$냉각이 어떠한 상황아래에서도 보증된다, (3) 사고시에 운전원에 의한 조작을 필요로 하지 않는다, (4) 출력밀도가 낮기 때문에 핵분열생성물질의 방출 우려가 적다는 등의 특징을 가지며 그 안전성으로 인해 도시부근에 위치할 수 있으며 또한 경제적으로도 석유나 석탄을 연소시키는 boiler보다 훨씬 유리하다.

  • PDF

A Study on the Combustion Characteristics of Organic Insulation Materials According to the Gas Toxicity Evaluation Method (가스유해성 평가방법에 따른 유기단열재의 연소특성에 관한 연구)

  • Shim, Ji-Hun;Lee, Jae-Geol;Han, Kyoung-Ho;Kim, Ju-Wan;Song, Seok-Hun;Jo, Hyung-Won;Yoon, Do-Young
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.519-524
    • /
    • 2022
  • Domestic building finishing materials are being evaluated according to KS F 2271 standards according to the notification of the Ministry of Land, Infrastructure and Transport, and this test is evaluated using laboratory animals. In this study, experiments were conducted on highly combustible organic insulation materials such as EPS, urethane, and phenolic foam. The purpose of this study was to analyze the cause of the behavioral suspension of the experimental mice by measuring the average behavioral suspension time of the mice caused by the harmful gas generated when these three types of insulation materials were burned. FTIR analysis and smoke density experiment were performed as a cause analysis method for the behavioral suspension of mice, and the experimental results were analyzed by dividing the causes of behavioral suspension into suffocation by particulate matter and toxic inhalation by gaseous substances. As a result of the test, urethane was evaluated as the most harmful insulation material, and as a result of FTIR analysis and smoke density test as a cause analysis for the gas toxicity test results, it is judged that the behavioral stop of the rats by suffocation is higher than the effect of toxic inhalation. This study is a basic study on the cause analysis of harmful gases, and it will be necessary to prepare the toxicity basis and analyze various materials and gases.

Study of Post-Fire Safe-Shutdown Analysis of a CANDU Main Control Room based on NEI 00-01 Methodology (NEI 방법론을 적용한 중수로 주제어실의 화재안전정지분석에 관한 연구)

  • Kim, In-Hwan;Lim, Heok-Soon;Bae, Yeon-Kyoung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.20-26
    • /
    • 2016
  • When the fire takes place in Nuclear Powr Plants(NPPs), the reactor should achieve and maintain safe shut-down conditions and minimize the radioactive material released to the environment. The U.S. Nuclear Regulatory Commission (NRC) has issued numerous generic communications related to fire protection over the past 20 years, after it issued its requirements in the Fire Protection Rule set forth in Title 10, Section 50.48 of the Code of Federal Regulations (10 CFR 50.48) and Appendix R to the 10 CFR 50. The and Nuclear Energy Institute (NEI) has developed a Methodology for Risk Informed Fire Safe-Shutdown Analysis, which is related to the Deterministic Method for Multiple Spurious Operations solutions. The aim of this study was to identify, achieve, and maintain Post-Fire Safe-Shutdown of the Main Control Room (MCR) of the CANDU reactor, even though one train of the multiple Safety Structures, Systems, and Components (SCCs) fail by the technical specification and analysis method.

Realization of Digital control of Grid_connected Modular Photovoltaic Inverter (계통연계형 모듈형 태양광 인버터의 디지털 제어의 구현)

  • Lee, Seung min;Lee, Woo cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.287-288
    • /
    • 2011
  • 주택 혹 산업용, 공공건물용으로 상용화 되어 있는 스트링 어레이 중앙 인버터 방식은 고압의 DC 배선으로 인한 안전문제, 고가의 고압 DC 차단기의 설치 및 과전압보호기 등으로 가격이 상승하게 되고 설치 시에도 패널간 균일 성능을 보장해야하고 스트링 상에 놓여 있는 패널 일부가 불량이거나 그림자가 져서 발전이 미비할 경우 전체 시스템 발전이 정지하거나 발전량이 미비해지는 문제가 생기므로 항상 최적의 상태로 운전할 수 없다. 그래서 이러한 태양광 발전 방식의 문제점을 해결하기 위해 각 모듈마다 마이크로 인버터를 장착하여 각각 패널마다 분산적인 MPPT(Maximum Power Point Tracking) 를 수행할 수 있고 DC 배선이 없기 때문에 시스템 설치비용을 획기적으로 절감할 수 있으며 안정성 문제도 중앙 인버터 방식보다 획기적으로 향상된다. 패널 또는 인버터 고장 시 전체 시스템의 차단 없이 교체가 가능 하여 시스템의 설비 이용률을 최대로 할 수 있다. 이러한 패널에 쓰이는 마이크로 인버터를 PSIM으로 구현하여 DLL로 통해 디지털 제어로 구현을 하고 시뮬레이션으로 통해 시스템의 효능을 알아보았다.

  • PDF

A Study for pathological observations on the exposured mouse to the HCl (HCl에 노출된 mouse의 병리학적 관찰에 관한 연구)

  • Cho, Nam-Wook;Chun, Ji-Hong;Lee, Jong-Cheon;Lee, In-Koo;Shin, Hyun-Jun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.361-364
    • /
    • 2012
  • 최근의 건축물은 다양한 소재의 마감재를 사용함으로서 화재 발생시 다양한 연소가스를 배출한다. 이때 건축물 내부의 화재에 노출된 재실자는 열 및 화상의 위험성과 함께 연기 및 독성가스의 피해를 받기 쉽다. 본 연구에서는 건축물 화재시 발생될 수 있는 HCl에 대한 표준가스를 제작하여 가스유해성시험을 수행하고, HCl 표준가스에 노출된 실험용 쥐의 표적장기적출실험을 수행하였다. 이를 통해서 유독가스에 노출된 실험용 쥐의 해부를 통한 표적장기-심장(Heart), 간(Liver), 폐(Lung), 비장(Spleen), 신장(Kidney), 흉선(Thymus)-의 손상여부와 KS F 2271에 의한 평균행동정지시간과의 관계를 분석하였다.

  • PDF

대형정지궤도위성 열평형시험용 열제어패널 지지 구조물 구조안전성 검토 결과

  • Im, Seong-Jin;Seo, Hui-Jun;Jo, Hyeok-Jin;Park, Seong-Uk;Son, Eun-Hye;Mun, Gwi-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.103.2-103.2
    • /
    • 2015
  • 10-3 Pa 이하의 고진공 환경과 $180^{\circ}C$ 이하의 극저온 환경에서 대형정지궤도위성의 고온 열평형 환경구현을 위한 열제어패널이 설계되었다. 열제어패널은 가로 2.2 m, 세로 2.6 m, 두께 2 mm의 구리판에 구리 튜브가 브레이징되어 있는 형태로 설계되었으며, 지상에서 6 m 이상의 높이에 설치되고 위성의 위치에 따라 이동이 가능해야 하기 때문에, 별도의 지지 구조물이 함께 설계되었다. 따라서, 열제어패널 설치 및 고정을 위한 지지구조물의 경우 160 kg의 무게를 견뎌내야 하며 이동 및 설치에 있어 구조적인 안전성이 확보 되어야 한다. 이에 본 연구에서는 상용유한요소해석 프로그램을 사용하여 열평형시험 시 위성체 상단부의 고온 환경모사를 위한 열제어패널 지지구조물에 대한 구조 안전성을 확인 하였다.

  • PDF