• Title/Summary/Keyword: 정전용량형

Search Result 171, Processing Time 0.026 seconds

The operation properties of DBD reactors in air pressure with varying the capacitance of reactors (정전 용량변화에 따른 대기압 DBD 반응기의 동작 특성 연구)

  • 박봉경;김윤환;장봉철;조정현;김곤호
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • The operation properties of DBD plasma reactors were observed by using 20 kV square pulse at the cylindrical and planar type of reactors in the condition of air pressure. The optimum operation frequency $f_0$ which optimizes the efficiency of operation was found as such $f_0\proptoexp(-C)$ when the current-voltage curve and charge-voltage curve were observed. Using these properties the dissipated power was evaluated. The dissipated power at the optimum frequency of operation was varied as the value of capacitance which is dependent on the structure and the dielectric material of the reactor, and had the maximum value at the specific value of capacitance. With these value of capacitance, DBD reactors which has a high level of efficiency can be formed.

  • PDF

Air detector using the change of dielectric constant for medical applications (의료분야 응용을 위한 유전상수 변화를 이용한 공기감지 장치)

  • Kim, Kyung-Hwa;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.864-870
    • /
    • 2010
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed air detection system with air control equipment, detection circuit and LabVIEW system for air sensing. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the Tygon tube of the mock system.

Characteristics of Flexible Transparent Capacitive Pressure Sensor Using Silver Nanowire/PEDOT:PSS Hybrid Film (은나노와이어·전도성고분자 하이브리드 필름을 이용한 유연 투명 정전용량형 압력 센서의 특성)

  • Ahn, Young Seok;Kim, Wonhyo;Oh, Haekwan;Park, Kwangbum;Kim, Kunnyun;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.3
    • /
    • pp.21-29
    • /
    • 2016
  • In this paper, we developed a flexible transparent capacitive pressure sensor which can recognize X and Y coordinates and the size of force simultaneously by sensing a change in electrical capacitance. The flexible transparent capacitive pressure sensor was composed of 3 layers which were top electrode, pressure sensing layer, and bottom electrode. Silver nanowire(Ag NW)/poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT:PSS) hybrid film was used for top and bottom flexible transparent electrode. The fabricated capacitive pressure sensor had a total size of 5 inch, and was composed of 11 driving line and 19 sensing line channels. The electrical, optical properties of the Ag NW/PEDOT:PSS and capacitive pressure sensor were investigated respectively. The mechanical flexibility was also investigated by bending tests. Ag NW/PEDOT:PSS exhibited the sheet resistance of $44.1{\Omega}/square$, transmittance of 91.1%, and haze of 1.35%. Notably, the Ag NW/PEDOT:PSS hybrid electrode had a constant resistance change within a bending radius of 3 mm. The bending fatigue tests showed that the Ag NW/PEDOT:PSS could withstand 200,000 bending cycles which indicated the superior flexibility and durability of the hybrid electrode. The flexible transparent capacitive pressure sensor showed the transmittance of 84.1%, and haze of 3.56%. When the capacitive pressure sensor was pressed with the multiple 2 mm-diameter tips, it can well detect the force depending on the applied pressure. This indicated that the capacitive pressure sensor is a promising scheme for next generation flexible transparent touch screens which can provide multi-tasking capabilities through simultaneous multi-touch and multi-force sensing.

Capacitive Parameter Estimation of Passive RF Sensor System using Unscented Kalman Filter (Unscented Kalman Filter를 이용한 원격 RF 센서 시스템의 파라메타 추정기법)

  • Kim, Kyung-Yup;Lee, John-Tark
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.168-173
    • /
    • 2008
  • 본 연구는 UKF Algorithm을 이용한 정전용량형 원격RF센서시스템을 개발하였다. 원격 RF센서 시스템이란 wireless, implantable 그리고 batterless을 만족하는 센서 시스템을 의미한다. 기존의 원격 RF센서 시스템은 보편적으로 집적회로 타입을 채택하지만, 그 구조의 복잡성과 전력소모의 제약을 받는다. 이러한 제약을 해결하기 위해 본 연구에서는 R, L 그리고 C만으로 구성되어있는 유도결합원리를 이용한 원격 RF센서 시스템을 제안하였다. 제안된 RF 센서 시스템은 압력 혹은 습도와 같은 환경의 변화를 정전용량 값으로 측정할 수 있으며 센서의 정전 용량 값을 측정하기 위해 비선형시스템의 파라메타추정에 적합한 Unscented Kalman Filter(UKF) 기법을 채택하였다. UKF 기법을 이용하기 위해 제안된 시스템은 페이저법을 사용하여 수학적으로 모델링되었다. 마지막으로, 제안된 UKF 알고리즘을 이용한 원력 RF센서시스템이 잡음환경에서도 정전용량값을 비교적 정확하게 추정가능함을 확인하였다.

  • PDF

Quantification of Rockwool Substrate Water Content using a Capacitive Water Sensor (정전용량 수분센서의 배지 함수량 정량화)

  • Baek, Jeong-Hyeon;Park, Ju-Sung;Lee, Ho-Jin;An, Jin-Hee;Choi, Eun-Young
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.27-36
    • /
    • 2021
  • A capacitive water sensor was developed to measure the capacitance over a wide part of a substrate using an insulated electrode plate (30 cm × 10 cm) with copper and Teflon attached on either side of the substrate. This study aimed to convert the capacitance output obtained from the condenser-type capacitance sensor into the substrate water content. The quantification experiment was performed by measuring the changes in substrate water weight and capacitance while providing a nutrient solution and by subsequently comparing these values. The substrate water weight and capacitance were measured every 20 to 30 seconds using the sensor and load cell with a software developed specifically for this study. Using a curve-fitting program, the substrate water content was estimated from the output of the capacitance using the water weight and capacitance of the substrate as variables. When the amount of water supplied was increased, the capacitance tended to increase. Coefficient of variation (CV) in capacitance according to the water weight in substrate was greater with the 1.0 kg of water weight, compared with other weights. Thus, the fitting was performed with higher than 1.0 kg, from 1.7 to 6.0 kg of water weight. The correlation coefficient between the capacitance and water weight in substrate was 0.9696. The calibration equation estimated water content from the capacitance, and it was compared with the substrate water weight measured by the load cell.

Capacitive Skin Piloerection Sensors for Human Emotional State Cognition (인간의 감정변화 상태 인지를 위한 정전용량형 피부 입모근 수축 감지센서)

  • Kim, Jaemin;Seo, Dae Geon;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.2
    • /
    • pp.147-152
    • /
    • 2015
  • We designed, fabricated, and tested the capacitive microsensors for skin piloerection monitoring. The performance of the skin piloerection monitoring sensor was characterized using the artificial bump, representing human skin goosebump; thus, resulting in the sensitivity of $-0.00252%/{\mu}m$ and the nonlinearity of 25.9 % for the artificial goosebump deformation in the range of $0{\sim}326{\mu}m$. We also verified two successive human skin piloerection having 3.5 s duration on the subject's dorsal forearms, thus resulting in the capacitance change of -6.2 fF and -9.2 fF compared to the initial condition, corresponding to the piloerection intensity of $145{\mu}m$ and $194{\mu}m$, respectively. It was demonstrated experimentally that the proposed sensor is capable to measure the human skin piloerection objectively and quantitatively, thereby suggesting the quantitative evaluation method of the qualitative human emotional state for cognitive human-machine interfaces applications.

Design of Capacitively-coupled Contactless Charging System using Class-E Amplifier (E급 증폭기를 이용한 전계결합형 비접촉 충전회로의 설계)

  • Choi, Byungwoo;Choi, Sungjin
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.173-174
    • /
    • 2013
  • 전기장만으로 에너지를 전송하는 전계결합형 비접촉 충전기술은 송수신부를 매개하는 AC링크를 구성하는 전극쌍의 정전용량확보에 한계가 있으므로, 이를 잘 활용하기 위한 송수신회로가 요구된다. 따라서 본 논문에서는 이를 감안하여 전계결합형 에너지전송에 적합한 매칭변압기를 사용한 E급 송수신회로 구조를 제안한다. 제안된 구조에서 AC-링크 캐패시터의 낮은 정전용량을 감안한 최적 설계방식을 제안하고 회로설계에 따른 성능을 모의실험을 통해 예측한다.

  • PDF

Capacitive Voltage Divider for a Pulsed High-Voltage Measurement (펄스형 고전압 측정용 용량성 전압 분배기)

  • Jang, S.D.;Oh, J.S.;Son, Y.G.;Cho, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1612-1615
    • /
    • 2001
  • 포항 방사광 가속기 2.5 GeV의 전자선형 가속기는 마이크로웨이브 발생원으로써 80 MW 클라이스트론(klystron) 11대와 입사부에 65 MW 클라이스 트론 1대를 사용한다. 전자빔 에너지의 효율적인 제어를 위하여 고출력 클라이스트론의 RF 전력과 입력 빔의 전력을 정확하게 측정해야 하며 응답특성이 양호한 측정장치와 정밀한 측정이 요구된다. 클라이스트론에 공급되는 전력은 캐소드에 인가되는 전압과 전류의 측정치로 계산된다. 비록 빔 전압측정에서의 작은 오차일지라도 클라이스트론 RF 출력 전력의 결과값에 큰 영향을 미친다. 따라서, 빔 전압의 측정시에 정확한 측정을 위하여 특별한 주의가 요구된다. 고전압 펄스전원장치 인 모듈레이터 (modulator)에서 발생되는 수백 kV(350-400 kV)의 전압을 측정하기 위하여 커패시터의 용량비로 입력전압을 분압하는 용량성 분압기(capacitive voltage divider, CVD)가 사용된다. 고압측 분압용 표준 콘덴서의 정전용량을 결정하는 주요인자는 고전압 절연유의 유전율(dielectric constant)이다. 그러므로, 측정범위 내의 전압, 주파수, 온도에 대하여 정전용량의 변화율이 작도록 설계하여야 한다. 본 논문에서는 펄스형 고전압 신호 측정을 위한 용량성 전압 분배기의 측정원리, 설계분석, 교정시험, 절연유의 온도변화에 따른 정전용량 변화 특성에 대한 실험 결과를 고찰하고자 한다.

  • PDF

Capacitance-type Alcohol Sensors using Porous Silicon Layer (다공질 실리콘 층을 이용한 정전용량형 알코올 센서)

  • Kim, Seong-Jeen
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.31-36
    • /
    • 1999
  • A capacitance-type sensor using porous silicon layer is developed to measure aqueous alcohol concentration. Since alcohol, so called ethanol, is very permeable into the silicon wafer, it is often used to help chemical reaction when the silicon wafer is processed under some aqueous solution. In this work, the sensing property was measured for the alcohol concentration from zero to near 100 percent with two types of samples with porous silicon layer formed in 25 and 35% HF solution, respectively. Good reliability as well as fast response time and good linearity were shown over 10kHz and the measured capacitance was observed to be inverse to alcohol concentration due to the decrease of the whole dielectric constant in porous silicon layer.

  • PDF