• Title/Summary/Keyword: 정온

Search Result 293, Processing Time 0.03 seconds

Design and Verification of Addressable Automatic Fire Detection System for Existing Apartments (기존아파트의 적용성을 고려한 주소형 자동화재탐지설비의 설계 및 검증)

  • An, Hyunsung
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.105-114
    • /
    • 2022
  • Non-fire activated fire alarms caused by such actions as cigarette smoke, cooking, and high humidity are fire safety risk factors. In such instances, it is important to quickly locate and replace the actuated detector. However, it is difficult to locate those detectors because most do not have an address function. While new apartments can incorporate addressable fire alarm detectors, in existing apartments there are limitations in converting over to addressable detectors due to cost and power line issues. This study developed an efficient address function for fire alarms in existing apartments. The newly developed system consists of the existing receiver, and a proposed addressable repeater and detector. Utilizing an experimental setup, the performance of the proposed address monitoring system was confirmed to be stable and compatible with the receiver and existing detectors.

Development of Rice Stem Maggot (Chlorops oryzae) in the Fields in Suweon (수원지방(水原地方)에 있어서 벼줄기굴파리의 발생경과(發生經過))

  • HWANG, C.Y.;LEE, Y.B.;KIM, .S.H.;LEE, M.H.;Choi, K.M.
    • Korean journal of applied entomology
    • /
    • v.24 no.2 s.63
    • /
    • pp.61-64
    • /
    • 1985
  • This study was carried out to investigate the seasonal occurrence and developmental periods of Rice stem maggot (RSM), Chlorops oryzae Matsumura, at laboratory and in the fields in $1980{\sim}1982$. RSM occurred three generations a year. Peak of the first, second, and third generation was middle to late May, early July and middle September. Longevity of the first generation adult averaged 18.9 days and the oviposition was 50 eggs per fly. The eggs, larval and pupal period was 7, 25, 14 days respectively.

  • PDF

A Case Study on the Characteristics of the Road Traffic Noise in Plant Communities (학교 정온시설 앞 식물군락 조성지역에서 도로교통소음 특성에 대한 사례연구)

  • Cho, Il-Hyoung;Lee, Nae-Hyun;Cho, Jung-Sang;Ko, Jung-Yong;SunWoo, Young;Park, Young-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.12
    • /
    • pp.1293-1303
    • /
    • 2006
  • This paper represents a comparison the difference between existence and nonexistence of soundproof trees for road traffic noise. Also we suggested that the simple equation has been derived using a single regression analysis for predicting levels of $Leq_{th}$ at a given distance from a road in terms of the flow rate, the mean speed of the traffic, and the percentage of the type vehicles in the existence and nonexistence of soundproof trees. We classified a vehicle into four and analyzed contribution rate to traffic volume. As a result, the order showed as followed: light vehicle>medium vehicle>heavy vehicle>motorcycle. However, the results of analyzing contribution rate with between traffic volume and traffic noise by the each type showed as followed; Motorcycle>Light vehicle>Medium vehicle>Heavy vehicle. This study showed that the most a lof of traffic volumes of the three vehicles(light vehicle, medium vehicle and motorcycle) and heavy vehicle were existed in 67 km/h and 61 km/h of car speed, respectively. The total traffic noise to the mean car speed decreased because of the inflow a lot of traffic volumes between 2016 and 2388 in the range of 67 km/h of light vehicle speed, in traffic composition of 4.75% heavy vehicles, and 1.11% motorcycle. the final result for this study showed that statistical paired t-test for between existence and nonexistence of soundproof trees was significant(p<0.05) and the difference between daytime and night in the location of the nonexistence of plant communities with the independent sample T-test was significant(p<0.05). However, the independent sample T-test for analyzing the variance of traffic noise between daytime and night was not significant(p>0.05).

Effect of Water temperature on the Climbing up of Larvae of Firefly, Luciola lateralis (Coleoptera: Lampyridae) (애반딧불이(Luciola lateralis) 유충의 상륙에 미치는 수온의 영향)

  • Oh, Hong-Sik;Kang, Young-Kook;Nam, Sang-Ho
    • Korean journal of applied entomology
    • /
    • v.48 no.2
    • /
    • pp.203-209
    • /
    • 2009
  • This study was conducted to investigate the relationship between the climbing up event of Luciola lateralis larvae and water temperature. In the laboratory condition, the larvae did not come out of water at constant temperature condition of 19.3${\pm}$$0.3^{\circ}C$ and tried to climb up at varying temperature condition of 20${\sim}$$22^{\circ}C$ (mean temperature 20.9${\pm}$$0.9^{\circ}C$) without success. However, they climbed up at constant temperature condition of 20.8${\pm}$$0.6^{\circ}C$. The frequency of the larval climbing up was highest as 63.6% at 20${\sim}$$21^{\circ}C$. The most larvae climbed up at approximately $21^{\circ}C$ of average daily water temperature, In the natural condition, the larvae climbed up at 19.8${\sim}$$21.7^{\circ}C$ and the frequency of the larval climbing up was high as 80.4% at 20${\sim}$$21^{\circ}C$. The larval climbing up was also little observed at 19${\sim}$$20^{\circ}C$ at which no larval climbing up was found in the laboratory experiment. No larvae attempted to climb up when water temperature was below $19^{\circ}C$ and above $22^{\circ}C$. It took 18 days from climbing up of larvae to appearance of adults. In its habitat, the range of water temperature required for larvae to climb up is assumed to be 19.6${\sim}$$21.8^{\circ}C$ and the most suitable water temperature may be 20.4${\pm}$$2.3^{\circ}C$. Therefore, the range of water temperature required for larvae to climb up is assumed to be 19.8${\sim}$$21.7^{\circ}C$, and the suitable water temperature range for larvae may be 20${\sim}$$21^{\circ}C$, and the most suitable temperature is thought to be $21^{\circ}C$.

Estimation of fire Experiment Prediction by Utility Tunnels Fire Experiment and Simulation (지하공동구 화재 실험 및 시뮬레이션에 의한 화재 설칠 예측 평가)

  • 윤명오;고재선;박형주;박성은
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.23-33
    • /
    • 2001
  • The utility tunnels are the important facility as a mainstay of country because of the latest communication developments. However, the utilities tunnel is difficult to deal with in case of a fire accident. When a cable burns, the black smoke containing poisonous gas will be reduced. This black smoke goes into the tunnel, and makes it difficult to extinguish the fire. Therefore, when there was a fire in the utility tunnel, the central nerves of the country had been paralyzed, such as property damage, communication interruption, in addition to inconvenience for people. This paper is based on the fire occurred in the past, and reenacting the fire by making the real utilities tunnel model. The aim of this paper is the scientific analysis of the character image of the fire, and the verification of each fire protection system whether it works well after process of setting up a fire protection system in the utilities tunnel at a constant temperature. The fire experiment was equipped with the linear heat detector, the fire door, the connection water spray system and the ventilation system in the utilities tunnel. Fixed portion of an electric power supply cable was coated with a fire retardant coating, and a heating tube was covered with a fireproof. The result showed that the highest temperature was $932^{\circ}c$ and the linear heat detector was working at the constant temperature, and it pointed at the place of the fire on the receiving board, and Fixed portion of the electric power supply cable coated with the fire retardant coating did not work as the fireproof. The heating tube was covered with the fireproof about 30 minutes.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Study on the Storage of Chestnut (밤 저장(貯藏)에 관(關)한 연구(硏究))

  • Yim, Ho;Kim, Choung-Ok;Shin, Dang-Wha;Suh, Kee- Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.170-175
    • /
    • 1980
  • A mass production of chestnut necessiates the development of economic long-term storage method. The main objective of this study was to confirm the technical aspect of the chestnut storage method which was developed by two year project and to review the method of commercial application. The chestnut used for the experiments were separated in brine $(5.5{\sim}6.0^{\circ}\:B{\acute{a}}ume)$ into matured and unmatured lots and fumigated with $CS_2$ at a 5 $lb/27\;m^3$ level for $25{\sim}30\;hrs.$ The chestnuts were packed in wooden boxes with sawdust (50% moisture) in the ratio of 1 : 1 by volume. The boxes were stored in the cold room $(1{\pm}1^{\circ}C,\;85{\sim}95%\;RH)$ and the cellar ($0{\sim}10^{\circ}C$, controlled only by circulating night cool air). The results obtained were as follows: 1. Fully matured chestnut could be successfully preserved $8{\sim}9\;months$ at a l0% decay level in the cold room and $4{\sim}5\;months$ months in cellar. 2. Immatured chestnuts wire inferior to the matured in storage stability. At the maximum storage period, its storage life was two months shorter. 3. The heat transfer equation of piled chestnuts with sawdust can be suggested as $T_{\infty}-T_0=(T_{\infty}-T_0){\cdot}10^{-t/320}$ and j and $f_h$ values were 1 and 320 min, respectively. 4. The chestnuts in the package of storage unit had longer shelf life than naked chestnut during the retail distribution at ambient temperature.

  • PDF

Stability of Chlorophyll during Processing and Storage of Salted Undaria Pinnatifida (염장(鹽藏)미역의 가공(加工) 및 저장조건(貯藏條件)과 Chlrophyll의 안정성(安定性))

  • Han, Bong-Ho;Bae, Tae-Jin;Kim, Byeong-Sam
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.71-77
    • /
    • 1984
  • A study on the stability of chlorophyll a in Undaria pinnatifida during blanching, salting and storage was carried out. Raw Undaria pinnatifida was blanched for 25 seconds in the temperature range of 70 to $100^{\circ}C$. To stabilize the chlorophyll a some chemicals such as 1% solutions of $Ca(CH_3CO_2)_2,{\;}Ca(OH)_2,{\;}MgCO_3,{\;}0.5%{\;}Ca(CH_3CO_2)_2$ with $0.5%{\;}MgCO_3$, and reed ash solution were used during/after blanching. The blanched product was salted with table salt after centrifuging for 2 minutes at 1500 rpm, and then again centrifuged after 48 hours for dewatering. The product which was mixed with 8% of table salt was sealed in a polyethylene film bag and stored at 10, 20, 30 and $40^{\circ}C$. The most effective blanching temperature for maximal residual amount of chlorophyll a was $85^{\circ}C$. The quantities of total organic and volatile acids were not significantly changed by the blanching temperature. Blanching in 1% chemical solutions showed bitter results than soaking in 1% chemical solutions for 20 minutes after blanching without chemicals. Reed ash and 0.5% $Ca(CH_3CO_2)_2$ with 0.5% $MgCO_3$ solutions were more effective than the 1% solutions of other chemicals, but the effect was not significant, compared with the group not treated with chemicals. The most reasonable ratio of added salt to dewater the product for 48 hours was 30% in w/w. The amount of total organic and volatile acids revealed no correlation with the amount of added salt. Color and odor of salted product was not severely changed during the storage of 77 days at $10^{\circ}C$. But the changes were accelerated with increasing storage temperatures. The degradation of chlorophyll a in salted product during storage could be interpreted as a first order reaction, and the rate constants at 10, 20, 30 and $40^{\circ}C$ were 0.1289, 0.1028, 0.0770 and 0.0550, respectively. $Q_{10}$ and the activation energy were 1.33 and 5.01 Kcal/g mole.

  • PDF

Population Dynamics of Effective Microorganisms in Microbial Pesticides and Environmental-friendly Organic Materials According to Storing Period and Temperature (저장기간 및 저장온도에 따른 미생물농약 및 친환경 유기농자재 유효미생물의 밀도변동)

  • Kim, Yong-Ki;Hong, Sung-Jun;Jee, Hyung-Jin;Shim, Chang-Kee;Park, Jong-Ho;Han, Eun-Jung;An, Nan-Hee;Lee, Seong-Don;Yoo, Jae-Hong
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • To work out quality control methods of environmental-friendly organic materials (EFOMs), the reason and basis for EFOM-selection and farmer's favorite formulation type of EFOMs, etc were investigated on farmers who had been practicing environmental-friendly agriculture. EFOMs used were soil amendments, control agents of plant diseases and insect pests, plant growth promotion formulations, in turns. In EFOMs application time, 22.7% of farmers sprayed EFOMs without delay after they were bought, in other hand, 77.3% of farmers used EFOMs which had been bought and stored for some period. Microbial density on seventeen environmental-friendly microbial formulates (EFMFs) including microbial pesticides, a microbial fertilizer, and environmental-friendly organic materials was investigated at different storing temperature and shelf life. When the microbial density of EFMFs was investigated without delay after they were bought, all used microbial pesticides and a microbial fertilizer was confirmed to be optimal for the certified density but two of environmental-friendly organic materials was confirmed not to be optimal. When microbial density of 17 EFMFs were investigated after storing them for six months at $4^{\circ}C$, only one of 9 microbial pesticides was confirmed not to be optimal, the other hand four of seven environmental-friendly organic materials not to be optimal, which each of their microbial density was less than the certified density. Population dynamics of microbial agents was much more influenced in fluctuated temperature (room temperature) than in static temperature condition ($5^{\circ}C$ and $25^{\circ}C$). Shelf life of microbial agents according to microbial formulation type were high in granule type, liquid wettable type and liquid type in turns.

Study on The Distribution of Applied 32P into Different Forms of P Compounds in the Soils During Incubation (논·밭 토양(土壤)에 시용(柴用)된 32P의 토양중(土壤中) 상이(相異)한 인산화합물(燐酸化合物)로의 분배(分配)에 관(關)한 연구(硏究))

  • Hong, Jung-Kook;Hong, Chong-Woon;Park, Sang-Ji;Steenberg, Kjell
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.12 no.3
    • /
    • pp.117-124
    • /
    • 1979
  • The present work was carried out to study the fate of applied phosphorus labelled with $^{32}P$ and its availability to plants in soils subjected to different management practices. The results can be summarized as follows (Table 3): 1. The applied phosphorus was transformed into different phosphorus compounds in the soils depending upon the management practices and soil characteristics. 2. In the flooded paddy soil (pH 5.8) added P after one week of incubation was transformed into various fractions, the order of abundance being: Al-P> Ca-P$${\sim_\sim}$$Fe-P> Org.-P. After two weeks the order changed to: Fe-P> Al-P> Ca-P> Org.-P. The amounts of the Fe-P and Al-P fractions were found to increase from the second week of incubation whereas a decrease in Ca-P was noticed with the organic-P remaining constant. The amount of available P decreased from the first to the third week of incubation, but increased thereafter. 3. In the volcanic ash soil a major proportion of the applied phosphorus was found in the Fe-P fraction during the whole experimental period. The interconversions of the $^{32}P$ among the different phosphate fractions was not as evident as in the case of flooded rice soil. The recovery of applied P was low and remained constant throughout the incubation period. 4. In the upland soils relatively more of the applied phosphorus was found in the Ca-P fraction as compared with those of the other soils. As in the flooded paddy soil $^{32}P$ in the Ca-P fraction decreased with increasing incubation time, whereas in the Fe-P fraction it increased with time. The recovery of added phosphate as available P followed different patterns for the cultivated and the uncultivated soils. In the cultivated soils lit was relatively high and remained nearly constant during the whole incubation period. In the uncultivated soil on the other hand, it was high at the earlier time of incubation, but decreased with incubation time.

  • PDF