• Title/Summary/Keyword: 정상 교합자

Search Result 133, Processing Time 0.021 seconds

The assessment of dentoalveolar compensation in facial asymmetry individuals: integration of cone beam CT and laser scanned dental cast images (Cone beam CT 영상과 석고모형 레이저 스캔 영상의 결합을 이용한 안면비대칭자의 치성보상 평가)

  • Song, Hyo-Kyung;Son, Woo-Sung;Park, Soo-Byung;Kim, Seong-Sik;Kim, Yong-Il
    • The korean journal of orthodontics
    • /
    • v.40 no.6
    • /
    • pp.373-382
    • /
    • 2010
  • Objective: The purpose of this study was to assess the dentoalveolar compensation in facial asymmetry individuals using an integration of a CBCT image and a laser scanned dental cast image. Methods: The subjects consisted of 30 adults with asymmetric mandibles and 20 adults with symmetric mandibles. The CBCT and laser scanned dental cast images were integrated with a registration technique. Canine and first molar position and angulation were assessed from reference coordinates. The differences between deviated and non-deviated sides were analyzed with the paired t-test. The differences shown according to menton deviation were also statistically analyzed using Pearson correlation analysis. Results: The experimental group showed deviated and non-deviated side differences (dev.-ndev.) in the position and angle of the canine and first molars. Menton deviation showed positive correlation with the deviation side (dev.-ndev.) for the maxillary and mandibular 1st molar angles, negative correlation with the deviation side for the vertical position of the maxillary 1st molars, transverse position of the mandibular canine, transverse position and vertical position of the mesio-lingual cusp of the mandibular 1st molars. Conclusions: The upper and lower canine and first molars of facial asymmetry individuals were compensated, so the transverse position, vertical position, and angle showed differences between the deviated/non-deviated sides.

Stress analysis of Multiloop Edgewise Arch Wire with various degree of tip back bend : a study using the finite element method (Multiloop Edgewise Arch Wire의 tip back 정도에 따른 응력 분포에 관한 유한요소법적 연구)

  • Lee, Young-Il;Cha, Kyung-Suk;Ju, Jin-Won;Lee, Jin-Woo
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.127-142
    • /
    • 2000
  • This study have been carried out to find out the mechnical effect of Multiloop Edgewise Arch Wire(MEAW) making use of the finite element method. The tip back bend of MEAW taken in this analysis is $5^{\circ},\;10{\circ}\;and\;15{\circ}$. In addition, Class II or up & down elastic is applied to find out stress distribution and their values in PDL. A adult male of normal occlusion was selected to create the models of teeth and PDL. And the model of MEAW was also created using commercial finite element code (ANSYS version 5.2). The MEAW is forcibly engaged with a class II or up & down elastic, to determine the initial stress generated in PDL. Comparing the compressive and tensile stress at each reference-planes, following results are obtained. 1. When a MEAW of $5^{\circ},\;10{\circ}\;15{\circ}$ tip back bend was engaged with Class II or up & down elastic, the distribution of compressive, tensile stress in entire PDL is similar in each case. 2. The values of compressive and tensile stress in PDL is higher in $15{\circ}$ tip back bend case than in $10{\circ}\;or\;15{\circ}$ tip back bend case. 3. In the distal PDL of 1st and 2nd molar, compressive stress appears. The compressive area is more wide and its values is higher in PDL of 2nd molar than those in 1st molar. The compressive area and its values become more wide and higher according to the increase of the tip back bend. 4. The values of compressive stress are comparatively smaIIer in PDL of molars than those in premolars. 5. Comparing class II and up & down elastic case, tensile stress values in anterior teeth PDL are smaller md their distribution is more wide in up & down elastic case than class If elastic case. On another hand, there is no difference in distribution and stress values in PDL of posterior teeth between two cases. 6. Comparing the tensile area in PDL of anterior teeth, tensile stress values are maximum in PDL of canine.

  • PDF

Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph (성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교)

  • Jang, Min-Guk;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.312-323
    • /
    • 2011
  • Objective: This study compared the bone thickness of the palate between lateral cephalogram and 3D model measurements. Methods: The subjects consisted of 30 adults (15 men,15 women) with a normal skeletal pattern and occlusion. The CT images were transformed to a 3D model, and were compared with the cephalometric image. Descriptive statistics for each variable were calculated. Results: In the 3D CT model, the mid-palatal area was the thickest part. It became thinner as the palate tapered laterally. In the male group, the thinnest portion was positioned 6 mm away from the mid-palate, while in the female group the thinnest portion was 8mm away from the mid-palate. Correlation analysis between the lateral cephalometric and 3D CT model revealed a significant correlation except in the mid palatal area and the area 2 mm lateral to the mid-palate in men, whereas there was a significant relationship in every area in the women. In both men and women, the highest correlation appeared in the area 8 mm lateral to the mid palate. Conclusions: Using regression analysis, an actual prediction of the bone thickness between the measured bone thickness of the lateral cephalometric radiograph and 3D model was made. This will provide useful information for mini-implant length selection when inserting into the palate.