• Title/Summary/Keyword: 정상단락

Search Result 95, Processing Time 0.034 seconds

Factors Influencing Critical Clearing Time in Network Connected to Wind Generation System (풍력발전시스템이 연계된 계통의 임계 제거시간에 미치는 요인)

  • Kim, Se-Ho;Kim, Ho-Chan;Yang, Ik-June
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.41-46
    • /
    • 2006
  • Generation of electricity using wind power has received considerable attention worldwide in recent years. In order to investigate the impacts of the integration of wind farm into utilities' network, various studies have been investigated. One such impact is related to the Critical Clearing Time (CCT) of wind power generation system. This paper reports investigation into the factors that influence the transient behavior of the wind power generation system following network fault conditions. It is shown that CCT can be affected by various factors contributed by the network. Such factors include capacity of wind power, power factor, the length of the interfacing line, etc. This investigation is conducted on a simulated grid-connected wind farm using Digsilent Power Factory.

Blood Disappearance Rates of Colloidal $^{198}Au$ in Normal and Cirrhotic Subjects: A Control and Clinical Study (교양 $^{198}$금(金)의 혈중제거율 : 그 정상치의 결정과 간(肝)경변증에서의 동태)

  • Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.2 no.1
    • /
    • pp.15-19
    • /
    • 1968
  • 정맥에 주사된 교양(膠樣) 방사성물질은 간(肝)에 있는 Kupffer 세포가 가진 탐식작용에 의해서 혈류로 부터 거의 완전히 제거된다. 이 원리는 정상인(正常入)과 간(肝)경변증환자에서 간(肝)혈류량을 측정하는데 이용된다. 일반적으로 간(肝)경변증때에는 간(肝)에서의 교양물질 추출율이 저하되기 때문에 혈중에서의 제거가 늦어진다하며, Shaldon 등은 혈중제거율측정을 이용하여, 추출율의 저하가 간내(肝內)에서 생기는 동맥과 정맥간의 단락(短絡) 때문에 초래되는 것을 증명하였다. 최근 혈중제거율을 몇가지 간(肝)질환을 진단하는데 이용한 보고가 나왔다. 그러나 그 방법에 대한 상세한 검토가 없었던 것 같다. 저자는 이번 연구에서 손쉽게 얻을 수 있는 교양$^{198}$금(金)을 사용하여 교양물질의 혈중제거율 측정방법을 검토하여 이 검사가 임상에서 통상적(通常的)으로 쓰일 수 있음을 밝혔다. (1) 정상인과 환자가 섞인 52명을 대상으로 동일인에서 $24{\sim}48$ 시간 간격을 두고 반복측정한 혈중제거율치의 오차는 통계학적으로 무시할 수 있었으며, 따라서 이측정은 근소한 오차한계내에서 되풀이할 수 있는 것을 알았다. (2) 정상인 172명에서 얻은 측정치를 토대로 하여 혈중제거율 정상치가 $3.31{\pm}0.73$분임을 알았다(교양 금(金) 입자의 크기에 따라 이 측청치는 달라진다). (3) 조직검사로 진단이 확정된 간(肝)경변증환자 23명을 조사하여 91.3%에서 혈중제거율이 정상한계를 넘어 연장(延長)되는 것을 알았다. 결론으로 혈중제거율검사는 임상에서 손쉽게 실시할 수 있는 간(肝)기능검사가 될 수 있다고 생각되며, 특히 간(肝)경변증을 진단하는데 도움이 된다고 믿는다.

  • PDF

Experimental Study on the Explosion and Fire Risks of Mobile Phone Batteries (휴대폰 배터리의 폭발 및 화재 위험성에 관한 실험적 연구)

  • Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.111-120
    • /
    • 2016
  • This is an experimental study to analyze the explosion and fire hazards of mobile phone batteries. Using the lithium-ion batteries currently used on smart phone as the experiment samples, the experiments were conducted by overcharging, internal and external short circuit, and thermal shock with the potential of explosion and fire caused by careless use or abnormal conditions. The experiment results showed that, in the case of overcharging and external short circuit, there was no explosion and fire hazard in the normal operation of the protection circuit module (PCM), but there were big risks when the PCM faulted conditions were assumed. In the case of the experiments by internal short circuit and thermal shock, such risks varied depending on a battery charge state. In other words, it could be verified that there were low risks of explosion and fire in a full discharge state, but there were high risks in a full charge state. These experiment results suggest that to minimize the explosion and fire hazards of mobile phone batteries, an alarm device is necessary when the PCM fault occurs. In addition, a solid battery case should be made and safety equipment, such as a cooling device to avoid high temperature, is needed.

하계 전기, 전자연합학술회의 및 산학협동 심포지엄 초록

  • 대한전기학회
    • 전기의세계
    • /
    • v.27 no.5
    • /
    • pp.33-54
    • /
    • 1978
  • (차례) 1.산학협동심포지업 (1)우리나라에서의 연구개발과 산학협동 (2)산학협동과 산업계의 역할 (3)산학협동의 현황과 진로 2.학술회의A (1)전력게통의 계층구조와 협조원리에 관한 연구 (2)2중층괴상회전자 유도전동기의 이론해석 (3)초고주파가열장치에 사용하는 철공진변압기의 해석적 설계 (4)한국전기기시험연구소 대전력단락 시험설비설계 (5)직류전동기제어를 위한 Thyristor Chopper정류회로에 관한 연구 (6)선로의 개폐정보를 포함하는 전력계통의 상태추정 (7)단일신경세포에 대한 ITEM 신호 특성 3.학술회의B (1)MMM-1 Computer System의 설계 및 제작 (2)Adaptive Delta Modulation System의 성능비교 연구 (3)6GHZ FMD마이크로파 무선전송장치의 개발 (4)적선도에 의한 회로망함수의 결정 (5)동맥혈압의 해석과 그의 전기적 유사모델 (6)피부감각의 정보전달 특성에 관하여 (7)선형직접회로의 공정설계 및 그 특성 조성 (8)DH L.D의 전기적포화현상에 관한 이론적 해석 (9)Potocoupler를 이용한 Isolator 4.학술회의C (1)Al-Al$_{2}$O$_{3}$ -Al박막구조의 전기적 특성 (2)이종금속에 샌드위치된 고분자물질의 단락전조 (3)유전체가 일부체워진 직 6면체의 캐비티의 다중모오드 해석 (4)반도체 가스 검지소자의 제조 및 그의 전기적 특성 (5)실리콘 산화공정에 대한 실험적 고찰 (6)진공증착법에 의한 InSb 박막제도에서 열처리효과 (7)(Ba$_{1}$-xBix) Tio$_{3}$ PTC thermistor의 첨가량의 최적건안 (8)금속박막증착시 두께조절 5.특별강연회 (1)일본에 있어서의 절력계통공학연구 (2)Linear Motor의 최근개발동향량도 높았다. valine과 leucine 및 aspartic acid, glycine과 glutamic acid, leucine과 aspartic acid 간에는 고도의 정상관, glycine과 serine, valine과 phenylalanine, threonine과 proline, phenylalanine과 arginine, methionine과 glutamic acid, histidine과 lysine 간에는 유의 정상관, 그리고 isoleucine과 lysine 간에는 유의한 부상관이 있었다. 4. lysine 함량은 단백질 함량과 정산곤, isoleucine 함량은 단빅질 함량과 부상관을 보였으며, alanine, valine, leucine 함량은 지방함량과 각각 유의한 정산관을 보였다. 5. 대두 단백질은 7.5% acrylamide gel 전기영동에 의해 품종에 따라 12~16개의 구성분으로 분리되었으며, 이들중 주구성분들은 상대이동도가 0.06(a), 0.14(b). 0.24(d) 이었고, 구성분 b의 함량이 품종간에 가장 변이가 컸으며, 구성분 b는 그밖의 주요 구성분들의 함량과 부의 상관이 있었고, 구성분 a는 단백질 함량과 정상관이 있었다. 6. 종실단백질 구성분들의 조합 특성 면에서 공시 86품종은 11개 유형군으로 분류되었으며, 우리나라와 일본품종은 미국품종에 비해 단백질구성분 조성이 훨씬 다양하였다. 7. 이동도가 매우 빠른 단백질 구성분 o(Rm 0.77) p(Rm 0.81)를 모두 갖고 있는 품종은 3품종, 모두 갖고 있지 않은 품종은 1품종이었고, 나머지 82품종은 o나 p중 한 구성분을 갖고 있었으며 그 분포율은 30 : 65 이었는데 미국계 품종은 우리나라 품종에 비해 구성분 o를 간고 있는 비율이 현저히 적었다. 8. 대두 종실은 개화후 22일까지 완만히, 그 이후 20~30일간 급속히

  • PDF

155.52 Mbps High Performance CMOS Receiver for STM-1 Application (STM-1급 155.52 Mbps 고성능 CMOS 리시버의 구현)

  • 채상훈;정희범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1074-1079
    • /
    • 1999
  • A high performance CMOS receiver for 155.52 Mbps STM-1 digital communication has been designed and fabricated. The ASIC operates properly with 155.52 MHz clock frequency in case of the data loss due to some system error such as transmission line open or data transfer fail. Also it operates properly in case the system starts after the power failure or system maintenance. The designed circuit has especially PLL based self oscillation loop which operates on abnormal environment which is added to main oscillation loop. The measured results show that the circuit operates well with 153.52 MHz clock frequency not only on normal environment but also on abnormal environment. Rms jitter of the PLL loop is about 23 ps.

  • PDF

Surgical outcome of severe pulmonary arterial hypertension secondary to left-to-right shunt lesions (심한 폐동맥 고혈압을 동반한 좌우 단락 질환 환자의 수술 후 경과)

  • Lee, Cha Gon;Jeong, Su-In;Huh, June;Kang, I-Seok;Lee, Heung Jae;Yang, Ji-Hyuk;Jun, Tae Gook
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.2
    • /
    • pp.195-202
    • /
    • 2010
  • Purpose : Despite recent advances in pulmonary hypertension management and surgery, appropriate guidelines remain to be developed for operability in congenital heart disease with pulmonary artery hypertension (PAH). Our aim was to evaluate clinical outcomes of patients with severe PAH who underwent surgical closure of left-to-right shunt lesions (LRSL) on the basis of pulmonary reactivity. Methods : We retrospectively reviewed 21 patients who underwent surgical closure of LRSL with severe PAH (${\geq}8$ Wood unit) from January 1995 to April 2009. The median age at operation was 26 years. Atrial septal defect, ventricular septal defect (VSD), VSD and patent ductus arteriosus (PDA), and PDA was present in 11, 4, 4, and 2 patients, respectively. Results : Operability was based on vasoreactivity of PAH. Of the 21 patients, 5 showed response to pulmonary vasodilator therapy and 8 showed vasoreactivity after balloon occlusion of defects. The remaining 8 patients were considered operable because of significant left-to-right shunt (Qp/Qs ${\geq}1.5$). Five patients underwent total closure of defects and 16 were left with small residual shunts. The median follow-up duration was 32 months. There was no significant postoperative mortality or morbidity. Systolic pulmonary artery pressure (PAP) decreased in all but 2 patients. All patients except 1 showed improvement of New York Heart Association functional class. Conclusion : Closure of LRSL in patients with severe PAH on the basis of pulmonary vasoreactivity seems reasonable. PAP and clinical symptoms improved in most patients. Further research is needed for the evaluation of long-term results.

An Electromagnetic Force Calculation of the Primary Winding in Power Distribution Transformer (소용량 배전용 변압기 권선의 전자력 계산)

  • Ha, Jung-Woo;Shin, Pan-Seok;Lee, Byung-Sung;Song, Il-Keun;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.164-166
    • /
    • 2006
  • 본 연구에서는 전력계통에서 발생되는 고장 전류에 의해서 변압기의 1차측 코일에 유도되는 전자력의 크기를 유한요소 전자계해석 프로그램(FLUX2D)을 이용하여 해석하였다. 50kVA, 13200/230(V) 단상 변압기의 권선간 전자력계산을 축대칭FEM을 이용하여 각 방향의 전자력을 분석하였다. 누설자속분포, 전류유입시 권선상호간에 작용하는 힘의 변화와 힘의 분포, 변압기 내부권선의 정상시와 고장전류시의 전자계비교를 전자계 해석을 통하여 변압기에 미치는 영향을 해석하였다. 변압기에 대전류가 유입되는 경우의 전자력 분석결과는 변압기의 절연설계 및 단락기계력에 대한 프레임 구조 설계를 위한 자료로 활용된다.

  • PDF

Experiments and analysis of CT Ratio Error for the damage cause of MOF (MOF 소손시 비오차 특성실험 및 분석)

  • Shin, Dong-Yeol;Kim, Seok-Gon;Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2089-2090
    • /
    • 2011
  • 본 논문에서는 MOF 소손시 비오차 발생으로 인한 전력사용량에 미치는 영향을 분석하기 위해 비오차를 측정하였다. 현재 MOF 고장건수는 전체파급고장의 약 10%이상 발생되고 있으며, 현장 순회시험을 통해 2009년 68건, 2010년 156건을 적출하였다. 이러한 MOF의 고장은 대부분 내부 CT 권선소손에 의해 발생되며, CT의 1차코일 또는 2차코일 단락시 유형별로 실험을 통해 비오차를 분석하였다. 특히 3상 수전고객은 ${\Delta}$-Y결선방식으로 MOF 정상시 불평형 전류는 중성선의 전류가 발생되지 않으나, MOF 이상시 중성선에 이상전류가 발생된다. 따라서 중성선의 이상전류를 측정하여 MOF 이상유무 판정 및 과부족 계량 오차 판정을 하기 위한 자료로 활용하였다.

  • PDF

Fontan Procedure for Functional Single Ventricle with Major Aortopulmonary Collateral Arteries (주요대동맥-폐동맥 측부혈관이 동반된 기능적 단심실 환자에서의 폰탄수술)

  • 홍순창;박한기;조범구;박영환
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.539-542
    • /
    • 2004
  • Not only morphology of pulmonary artery or pulmonary artery resistance, but major aortopulmonary collateral arteries are risk factors of Fontan procedure. We report a successful Fontan procedure after rehabilitation of pulmonary arteries by unifocalization and systemic to pulmonary shunt in a high risk Fontan candidate with functional single ventricle combined with hypoplastic pulmonary arteries and major aortopulmonary collateral arteries supplying most of the bilateral lung field.

Ground fault current variation of 22.9kV CD type superconducting cable system (22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화)

  • Lee, Geun-Joon;Lee, Sang-Han;Son, Song-Ho;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.46-47
    • /
    • 2006
  • 본 논문은 CD형 초전도 케이블을 22.9kV 다중접지 배전계통에 적용한 경우 불평형 지락 고장이 초전도 케이블에 미치는 영향을 검토하고 이로 인한 중성선 전류의 변화 및 계통보호를 위한 대책을 논한다. 3상 CD형 초전도 케이블을 사용하는 경우 귀로선은 전향선과 전류가 반대이면서 거의 동일한 전류가 흐르므로 회로의 인덕턴스를 크게 줄일 수 있지만 이를 위해 회로를 단락하여 운전하는 경우 지락고장시 영상회로가 별도로 존재하지 않으면 지락전류를 저감시키는 결과를 초래하게 되어 계통보호에 영향을 주게 된다. 본 논문은 EMTDC 프로그램을 활용하여 이 현상을 XLPE 케이블 계통과 비교, 모의하는 한편, 정상적인 보호계전기 동작이 가능토록 하는 대책에 대해 논한다.

  • PDF