• Title/Summary/Keyword: 정사각 평판

Search Result 3, Processing Time 0.024 seconds

Free Vibration Analysis of Size and Position of hole in Square Plate (사각 평판에서 홀의 크기와 위치에 따른 자유진동해석)

  • 최경호;최태원;김형준;안찬우;김현수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.664-667
    • /
    • 1997
  • In this study, it is attempted to obtain the optimized size of holes in 15 square plate models where a hole exists on every quadrant of a plate, and to get eigenvalues and mode shapes by performing free vibration analysis for each model. For free vibration analysis and optimization of' hole sizes, the uniaxial tension is applied for the loading condition. From the results of this study, it is known that more stable structures can be designed by changing the natural frequency depending on the location and the optuiiunl size of holes. and further studies are considered to be necessary for the basic design information.

  • PDF

Effect of injection molding conditions on morphology of binary polymer blends (이성분계 고분자 블렌드의 형태학에 미치는 사출 조건의 영향)

  • Son, Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.1
    • /
    • pp.165-169
    • /
    • 2008
  • The effect of processing conditions on the morphology of polyphenyleneoxide (PPO)/polyamide 6 (PA 6) blends were investigated. Injection molded part with a $15cm{\times}15cm{\times}3.2mm$ sized plate was molded with various injection molding conditions, and the morphology of the injection molded blends was investigation by using SEM. As a result, we found that molded part shows very complicated morphology because it has experienced complex thermal, shear and elongation history during the processing.

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF