• Title/Summary/Keyword: 정보지기

Search Result 85, Processing Time 0.019 seconds

Measuring the Professional Development Needs for Technical and Vocational Education and Training Staff in Nepal: A Look at Teachers' Perceptions (네팔 직업기술교육훈련 교사들의 교육훈련 프로그램 요구조사)

  • Lim, Jin Ho;Kim, Dongwook
    • Journal of Practical Engineering Education
    • /
    • v.12 no.1
    • /
    • pp.163-176
    • /
    • 2020
  • Promoting job growth and quality has been central to developing countries to reduce poverty for decades. In this regard, Nepal is not unique in its need to develop effective TVET programme as it is considered showing positive association with workforce development and productivity. While the copious academic literature has highlighted upon staff training programme in general education, it encounters lack of adequate attention in the field of TVET education. The purpose of the study is to identity and prioritise the professional development needs for the teachers of TVET sector in Nepal. A sample(N=317) of Nepalese teachers from seven provinces were asked to answer the scale. The Borich needs assessment model was employed to assess the perceived level of importance and present preferred training modules among 29 teaching subjects. Moreover, a quadrant analysis using 2×2 matrix was used as a diagnostic tool to denote overriding training topics. The result shows that following competence skills constructs were perceived to be in high need of enhancement as well as in existence of discrepancies: 'occupational characteristics of TVET trainer', 'training needs analysis and curriculum development', 'curriculum development based on national competence standard(NCS)', and 'Institution management evaluation'.

Measurement of the Device Properties of a Ionization Smoke Detector to Improve Predictive Performance of the Fire Modeling (화재모델링 예측성능 개선을 위한 이온화식 연기감지기의 장치물성 측정)

  • Kim, Kyung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.27-34
    • /
    • 2013
  • The high prediction performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of PBD (Performance Based fire safety Design). The main objective of the present study is to measure input information in order to predict the accurate activation time of smoke detector into a Large Eddy Simulation (LES) fire model such as FDS (Fire Dynamics Simulator). To end this, FDE (Fire Detector Evaluator) which can measure the device properties of detector was developed, and the input information of Heskestad and Cleary's models was measured for a ionization smoke detector. In addition, the activation times of smoke detectors predicted using default values into FDS and measured values in the present study were systematically compared. As a result, the device properties of smoke detector examined in the present study showed a significant difference compared to the default values used into FDS, which resulted in the considerable difference of up to 15 minutes or more in terms of the activation time of smoke detector. The database (DB) on device properties of various smoke and heat detectors will be built to improve the reliability of PBD in future studies.

The Research on the Phytosociological Characteristics of Abies nephrolepis Maxim. Community in Mt. Seorak, Korea (설악산 분비나무군락의 식물사회학적 특성)

  • Lee, Ho-Young;Chung, Bo-Kwang;Chun, Young-Moon;Oh, Choong-Hyeon
    • Korean Journal of Environment and Ecology
    • /
    • v.35 no.1
    • /
    • pp.37-47
    • /
    • 2021
  • This study carried out the plant sociological survey of Abies nephrolepis forest in Mt. Seorak, which is in danger of deterioration due to the accelerated climate change. We examined seventy quadrats obtained from the survey and used the TWINSPAN technique to classify communities. We then performed the DCA method for the sequence analysis and analyzed the characteristics of each community. A. nephrolepis forest of Mt. Seorak is composed of four communities (A. nephrolepis-Lonicera caerulea var. edulis community, A. nephrolepis-Acer komarovii community, A. nephrolepis-Ac. pseudosieboldianum community, and A. nephrolepis-Betula costata community). Each community showed a different distribution according to location because different microenvironments are formed depending on location such as altitude and slope direction, resulting in different species composition. Each community showed differences in environmental characteristics such as altitude, rock ratio, soil characteristics, and litter layer thickness. As a result, there were significant differences between communities in the number of species and individuals, coverage, tree size, and species diversity, as well as differences in species composition. The A. nephrolepis-L. caerulea var. edulis and A. nephrolepis-Ac. komarovii communities were located in high altitude with high rock ratios and had little development of tree layer. On the other hand, the A. nephrolepis-Ac. pseudosieboldianum and A. nephrolepis-B. costata communities were relatively in low altitude with high soil ratio and had the development of tree layer with high species diversity.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

The Historical and Cultural Landscape, and the Scenic Value of Mangjinsan Mountain in Jinju (진주(晉州) 망진산(望晉山)의 역사문화경관과 명승적 가치)

  • Kim, Se-Ho
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.40 no.3
    • /
    • pp.10-19
    • /
    • 2022
  • In this study, historical and cultural landscapes were reviewed focusing on Mangjinsan Mountain in Jinju, Gyeongsangnam-do, and the scenic value was examined through this. First, Mangjinsan Mountain was noted in history, as Ansan(案山, a mountain on the opposite side of a housing/grave site) in Jinju, where Bongsu(烽燧, the beacon fire station) is located. Information on Mangjinsan Mountain was gradually doubled due to its status, and the beacon fire station of Mangjinsan Mountain was in charge of defending the Jinju area. Mangjinsan Mountain was described as a symbolic landscape of Jinju. Regarding the etymology of Mangjinsan Mountain, Sung Yeo-Sin(成汝信) analyzed the geography of Jinju and suggested that it was a place name originating from the phoenix. However, looking at various records, it is confirmed that the name of Mangjinsan Mountain is maintained uniformly, but the inscription is not unified. Second, Mangjinsan Mountain became one of the major stage for the Japanese Invasion of Korea in 1592, and in 1597. It is confirmed to be a place which has joys and sorrows, for that it provided an opportunity to win the Siege of Jinju in 1592, but many casualties occurred in 1597. On the other hand, in the area of Mangjinsan Mountain Byeolseo(別墅), temples, and administrative facilities were located to establish cultural history of the time, and in the 19th century, Manggyeongdae Pavilion was built due to the scenic value of viewing Jinju Castle. These are examples of testimony how Mangjinsan Mountain has an important meaning in Jinju's history and culture. Third, in the late Joseon Dynasty, a poem reciting Mangjinsan Mountain appears, which shows that the Mountain has established itself as a scenic site in Jinju. The description of Mangjinsan Mountain is confirmed in the literature that lists the scenic sites of Jinju. On the other hand, writers who lived in Jinju paid attention to the beacon fire station, singing about the peaceful world without war and looking back the history. In the 19th century, Jeonbyeolyeon(a farewell party) was held, which seems to be the result of the beauty of viewing Jinju and overviewing the area. Through the facts, the symbolism and scenic value of Mangjinsan Mountain in Jinju were confirmed.