• Title/Summary/Keyword: 정변형

Search Result 6, Processing Time 0.032 seconds

Panoramic Image Improvement using Forward Warping and Bilinear Interpolation Method (정변형과 양선형 보간법을 이용한 파노라마 영상 개선)

  • Kim, Kwang-Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2108-2112
    • /
    • 2012
  • In this paper, we propose a method obtaining an improved panoramic image with forward warping transformation and bilinear interpolation in recovering information lost during the transforming process. The proposed fish-eyed image restructuring method is verified to be sufficiently effective in the experiment with various forms of fish-eyed lens images.

A Non-edge Following Method for Solving Linear Programs (선형계산문제의 비정변형해법의 연구)

  • 백승규;안병훈
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.6 no.2
    • /
    • pp.25-34
    • /
    • 1981
  • In this paper, we propose a non-edge following method for linear programs. Unlike alledged poor performance of algorithms of this type, this method performs well at least with 25 randomly generated problems. This method is comparable to Rosen's gradient projection method as applied to the dual formulation. The latter is of general purpose, and no implementation rules are available for linear program applications. This paper suggests ways of finding improving dual feasible directions, and of allowing to move across the extreme faces of a higher dimension polyhedron. Rather simple computational rules are provided for projection operations needed at each iteration.

  • PDF

인코넬600 합금의 응력부식균열 탐지

  • 성게용;이승혁;김인섭;윤용구
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.104-109
    • /
    • 1997
  • 인코넬600 합금을 열처리상태 및 변형속도등이 서로 다른 응력부식균열(SCC) 발생 조건하에서 정변형속도 시험법으로 인장시켜 그때 발생되는 AE신호와 부식전류를 측정하여 균열거동과 비교하므로서 SCC 발생 및 진전을 AE로서 적절히 탐지할 수 있는가를 연구하였다. 그 결과 SCC. 연성파괴 및 기계적인 변형에서 발생되는 AE는 amplitude 준위에 의해 식별가능하며, 이것은 AE amplitude 준위가 AE발생원을 식별할 수 있는 중요한 변수가 될 수 있음을 의미한다. 또한 AE 발생시점과 전기 화학적 전류변동이 들 일치하는 것으로 나타나 입계응력부식 균열 진전이 AE에 의해 적절히 탐지될 수 있음을 알 수 있다.

  • PDF

Rheological Studies of the Fish Protein upon the Thermal Processing (열처리 공정에 따른 생선단백질의 물성 연구)

  • Kang, Byung-Sun;Kim, Byung-Yong;Lee, Jae-Kwun
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.103-109
    • /
    • 1994
  • Changes in the rheological properties and the linear viscoelasticity of fish protein gel upon the thermal processing were studied by using mathematical models with stress-relaxation data. The linear viscoelasticity of surimi gel was observed in the range of the true strain $0.105{\sim}0.693$ and cross-head speed $50{\sim}250\;mm/min$ applied in this study. The results of the generalized Maxwell analysis showed that the magnitudes of elastic elements $(E,\;E_e)$ were increased, but the viscous element $({\eta}) $was decreased, as the cross-head speeds and strain levels were increased. Compared to the protein gel heated directly at $90^{\circ}C$ without preheating, the protein gel pretreated at $4^{\circ}C$ and $40^{\circ}C$ showed the higher elastic modulus, but showed different trends in the viscous component, depending on the rheological model applied. Thus, the approaching methods and curve fitting of two mathematical models of stress-relaxation to describe the viscoelastic properties of fish protein gel were discussed.

  • PDF

Evaluation of the Stress Corrosion Cracking Behavior of Inconel G00 Alloy by Acoustic Emission (음향 방출에 의한 인코넬 600 합금의 응력 부식 균열 거동 평가)

  • Sung, Key-Yong;Kim, In-Sup;Yoon, Young-Ku
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.174-183
    • /
    • 1996
  • Acoustic emission(AE) response during stress corrosion cracking(SCC) of Inconel 600 alloy has been monitored to study the AE detectability of crack generation and growth by comparing the crack behavior with AE parameters processed, and to evaluate the applicability as a nondestructive evaluation(AE) by measuring the minimum crack size detectable with AE. Variously heat-treated specimens were tensioned by constant extension rate test(CERT) in various extension rate to give rise to the different SCC behavior of specimens. The AE amplitude level generated from intergranular stress-corrosion cracking(IGSCC) is higher than those from ductile fracture and mechanical deformation, which means the AE amplitude can be a significant parameter for distinguishing the An source. AE can also provide the effective means to identify the transition from the small crack initiation and formation of dominant cracks to the dominant crack growth. Minimum crack size detectable with AE is supposed to be approximately 200 to $400{\mu}m$ in length and below $100{\mu}m$ in depth. The test results show that AE technique has a capability for detecting the early stage of IGSCC growth and the potential for practical application as a NDE.

  • PDF