Dose Verification Using Pelvic Phantom in High Dose Rate (HDR) Brachytherapy (자궁경부암용 팬톰을 이용한 HDR (High dose rate) 근접치료의 선량 평가)

  • 장지나;허순녕;김회남;윤세철;최보영;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2003
  • High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a phantom. In this study, the phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the phantom were then compared with the treatment planning system for the dose verification. The phantom needs to be designed such that the dose distributions can be quantitatively evaluated by utilizing the dosimeters with a high spatial resolution. Therefore, the small size of the thermoluminescent dosimeter (TLD) chips with a dimension of <1/8"and film dosimetry with a spatial resolution of <1mm used to measure the radiation dosages in the phantom. The phantom called a pelvic phantom was made from water and the tissue-equivalent acrylic plates. In order to firmly hold the HDR applicators in the water phantom, the applicators were inserted into the grooves of the applicator holder. The dose distributions around the applicators, such as Point A and B, were measured by placing a series of TLD chips (TLD-to-TLD distance: 5mm) in the three TLD holders, and placing three verification films in the orthogonal planes. This study used a Nucletron Plato treatment planning system and a Microselectron Ir-192 source unit. The results showed good agreement between the treatment plan and measurement. The comparisons of the absolute dose showed agreement within $\pm$4.0 % of the dose at point A and B, and the bladder and rectum point. In addition, the relative dose distributions by film dosimetry and those calculated by the planning computer show good agreement. This pelvic phantom could be a useful to verify the dose calculation algorithm and the accuracy of the image localization algorithm in the high dose rate (HDR) planning computer. The dose verification with film dosimetry and TLD as quality assurance (QA) tools are currently being undertaken in the Catholic University, Seoul, Korea.

  • PDF

A Study on Compensation for Imaging Qualities Having Artifact with the Change of the Center Frequency Adjustment and Transmission Gain Values at 1.5 Tesla MRI (1.5 Tesla 기기에서 중심주파수 조정과 송 신호강도(Transmission Gain)값 변화에 따른 인공물이 있는 자기공명영상의 질 보상에 관한 연구)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Han-Joo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.244-252
    • /
    • 2009
  • The purpose of this study is to compensate for susceptibility and a ferromagnetic body artifact using CFA and TGV on MR Imaging. A total of 30 patients (15 men and 15 women, mean age: 45 years) were performed on head and neck diseases. MR Unit used a 1.5T superconducting magnet (GE medical system, High Density). This study have investigated by changing with CFA and TGV (70, 90, 110, 130, 150) searching for compensation values about susceptibility and a ferromagnetic body artifact in 60 kg standards of body weight (p<0.05). As a quality results, Image qualities were obtained at different score from CFA and TGV (70, 90, 110, 130, $150=3.23{\pm}0.35$, $4.31{\pm}0.02$ $4.23{\pm}0.21$, $5.12{\pm}0.25$, $7.13{\pm}0.72$, $8.31{\pm}0.01$, $5.21{\pm}0.15$, $6.14{\pm}0.08$, $5.23{\pm}0.72$, $5.91{\pm}0.06$, p<0.05). Absolute CNRs (TG, CNRpre, CNRpost) were acquired with (70:$-1.44{\pm}0.11$, $-2.7{\pm}0.04$, 90:$-2.18{\pm}0.42$, $-4.41{\pm}0.43$, 110:$-2.89{\pm}0.43$, $-5.23{\pm}0.02$, 130:$-2.34{\pm}0.05$, $-5.26{\pm}0.01$, 150: $-2.09{\pm}0.08$, $-3.87{\pm}0.12$, p<0.05). In conclusions, this study could be compensated for metal and flow artifacts surrounding the tissues having artifact by changing CFA and TGV.

  • PDF

Cloning, cSNP Identification, and Genotyping of Pig Complement Factor B(CFB) Gene Located on the SLA Class III Region (SLA Class III 영역의 돼지 Complement Factor B(CFB) 유전자의 Cloning, cSNP 동정 및 유전자형 분석)

  • Kim, Jae-Hwan;Lim, Hyun-Tae;Seo, Bo-Yeong;Zhong, Tao;Yoo, Chae-Kyoung;Jung, Eun-Ji;Jeon, Jin-Tae
    • Journal of Animal Science and Technology
    • /
    • v.50 no.6
    • /
    • pp.753-762
    • /
    • 2008
  • The primers for RT-PCR and RACE-PCR were designed by aligning the pig genomic sequence and the human complement factor B(CFB) coding sequence(CDS) from the GenBank. Each PCR product was amplified in pig cDNA and sequencing was carried out. The CDS length of pig CFB gene was determined to be 2298 bp. In addition, the pig CDS was more longer than human and mouse orthologs because of insertion and deletion. The identities of porcine nucleotide sequences with those of human and mice were 84% and 80%, and the identities of amino acids were 79% to 77%, respectively. Three complement control protein(CCP) domains, one Von Willebrand factor A(VWFA) domain and a serine protease domain, that are revealed typically in mammals, were found in the pig CFB gene. Based on the CDSs determined, the primers were designed in intron regions for amplification of entire length of exons. In amplification and direct sequencing with genomic DNAs of six pig breeds, three cSNPs(coding single nucleotide polymorphisms) were identified and verified as missense mutations. Using the Multiplex-ARMS method, we genotyped and verified the mutations identified from direct sequencing. To demonstrate recrudescence, we performed both direct sequencing and Multiplex-ARMS with two randomly selected DNA samples. The genotype of each sample exhibited the same results using both methods. Therefore, three cSNPs were identified from pig CFB gene and that can be used for haplotype analysis of the swine leukocyte antigen(SLA) class III region. Moreover, the results indicate that the Multiplex-ARMS method should be powerful for genotyping of genes in the SLA region.

Nonvital Pulp Therapy of Elongation of Roots of Mandibular Cheek Teeth in Pet Rabbits (애완토끼에서 과잉성장된 하악치아의치신경치료 연구)

  • Park, Cheon-Sik;Cha, Se-Yeoun;Kang, Min;Kim, Jury;Jeong, Soon-Wuk;Jang, Hyung-Kwan
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.474-482
    • /
    • 2012
  • Elongation of cheek teeth roots in pet rabbits is very common, and is associated with malocclusion followed by reduced appetite, salivation, periapical abscess, and epiphora. Conservative methods including medication, drainage, irrigation, tooth trimming, intraoral and extraoral extraction, surgical treatment of periapical abscessation, and diet control have been adapted as the only treatments to resolve elongation of teeth roots. However, remaining challenges include the long-term period of cure and recurrence. This study was performed to investigate the possibility of nonvital pulp therapy on elongation of the mandibular cheek teeth roots in pet rabbits. Thirty-one pet rabbits with dental problems due to root elongation were submitted. Ten pet rabbits among them were treated by nonvital pulp therapy procedures (group A), while the others were treated by conservative methods (group B). Appetite improved within 1-5 days after nonvital pulp therapy and the treatment was discontinued 1 month postoperatively in group A. Abscess occurred in another site not treated with nonvital pulp therapy in only two rabbits. Growth of the mandibular cheek teeth treated with nonvital pulp therapy stopped, resulting in malocclusion, intraoral inflammation from the enamel spur, and abscess of the teeth roots. In the group B rabbits treated with conservative therapy, partial drainage, long term medication, recurrent oral trimming and control of repeated oral inflammation occurred. Consequently, buccotomy or tooth extraction was performed in group B. Owners were satisfied with nonvital pulp therapy preventing dental root abscess and repeated troubles including inflammation and malocclusion and reduction of the treatment period. These results suggest that nonvital pulp therapy can be performed on pet rabbits with elongation of mandibular cheek teeth roots.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

3-Dimensional Reconstruction of Parallel fiber-Purkinje Cell Synapses Using High-Voltage Electron Microscopy (고압전자현미경을 이용한 소뇌 평행섬유-조롱박세포간 신경연접의 3차원 재구성)

  • Lee, Kea-Joo;Kweon, Hee-Seok;Kang, Ji-Seoun;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.35 no.1
    • /
    • pp.31-39
    • /
    • 2005
  • Synapses are contact points where one neuron communicates with another. The morphological change of synapses under various physiological or pathological conditions has long been hypothesized to modify their functional properties. 3-dimensional (3-D) reconstruction of synapses with serial ultrathin sections has contributed to the understanding of ultrastructural dimensions and compositions of synapses. The 3-D reconstruction procedures, however, require a great amount of expertise as well as include prohibitively timeconsuming processes. Here, we introduce efficient 3-D reconstruction technique using high-voltage electron microscopy (HVEM). Primarily, we established an optimal section thickness and staining condition to observe synaptic structures in detail under HVEM. The result showed that synaptic profiles were preserved at the section thickness of 250 nm without the overlapping of synaptic ultrastructures. An increase in the reaction time of en bloc staining was most efficient to enhance contrast than the extension of postembedding staining or the addition of uranyl acetate during dehydration. Then, 3-D reconstruction of parallel fiber-Purkinje cell synapses in the rat cerebellum was carried out with serial HVEM images and reconstruction software. The images were aligned and the contours of synapses were outlined on each section. 3-D synapses were finally extracted from the section files by grouping all the synaptic contours. The reconstructed synapse model clearly demonstrated the configuration of pre and postsynaptic components. These results suggest that 3-D reconstruction of synapses using HVEM is much efficient and suitable for massive quantitative studies on synaptic connectivity than conventional TEM approach using numerous ultrathin sections.

Arthroscopically Assisted Lateral Release and Medial Imbrication for Recurrent Patella Dislocation (재발성 슬개골 탈구에서 관절경적 외측 유리술 및 내측부 중첩술)

  • Kang, Sung-Shik;Yoo, Jae-Doo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.9 no.2
    • /
    • pp.98-103
    • /
    • 2010
  • Purpose: We reported the results of arthroscopically assisted lateral release and medial imbrication for the recurrent patella dislocation. Materials and Methods: Twenty patients (20 knees) underwent arthroscopically assisted surgery for the recurrent patella dislocation. There were 4 males and 16 female. The average age was 20.2 years. All patients had definite trauma history and average follow-up period was 19 months. The surgical results were evaluated according to the Lysholm knee score and the Kujala score. The congruence angle and lateral patellofemoral angle were measured on plain radiograph and the tibial tubercle-trochlear groove distance was calculated on computerized tomography. Results: The median value of preoperative congruence angle was $16.5^{\circ}$ (range, $0.0{\sim}+34^{\circ}$) and the average final follow-up was $-6.4^{\circ}$ (range, $-19{\sim}10^{\circ}$) with statistically significant improvement (p=0.025). The median value of preoperative Lysholm knee score was 70 (range, 63~81) and the final follow-up score had changed to 88 (range, 80~95) with statistically significant improvement (p=0.0341). The median value of preoperative Kujala score was 72 (range, 65~80) and the average final follow-up score showed 87 (range, 80~92) with statistically significant improvement (p=0.024). Recurrent dislocations after surgery occurred in 2 cases, one case which showed positive "thumb to forearm test" had been treated with medial patellofemoral ligament reconstruction. Conclusion: Arthroscopically assisted lateral release and medial imbrication for recurrent patella dislocation without bony malaligmenent showed the effective treatment, but would be inappropriate for the patients with the generalized joint laxity.

  • PDF

Speech Recognition Using Linear Discriminant Analysis and Common Vector Extraction (선형 판별분석과 공통벡터 추출방법을 이용한 음성인식)

  • 남명우;노승용
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.35-41
    • /
    • 2001
  • This paper describes Linear Discriminant Analysis and common vector extraction for speech recognition. Voice signal contains psychological and physiological properties of the speaker as well as dialect differences, acoustical environment effects, and phase differences. For these reasons, the same word spelled out by different speakers can be very different heard. This property of speech signal make it very difficult to extract common properties in the same speech class (word or phoneme). Linear algebra method like BT (Karhunen-Loeve Transformation) is generally used for common properties extraction In the speech signals, but common vector extraction which is suggested by M. Bilginer et at. is used in this paper. The method of M. Bilginer et al. extracts the optimized common vector from the speech signals used for training. And it has 100% recognition accuracy in the trained data which is used for common vector extraction. In spite of these characteristics, the method has some drawback-we cannot use numbers of speech signal for training and the discriminant information among common vectors is not defined. This paper suggests advanced method which can reduce error rate by maximizing the discriminant information among common vectors. And novel method to normalize the size of common vector also added. The result shows improved performance of algorithm and better recognition accuracy of 2% than conventional method.

  • PDF

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF

A Study on the Serialized Event Sharing System for Multiple Telecomputing User Environments (원격.다원 사용자 환경에서의 순차적 이벤트 공유기에 관한 연구)

  • 유영진;오용선
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.05a
    • /
    • pp.344-350
    • /
    • 2003
  • In this paper, we propose a novel sharing method ordering the events occurring between users collaborated with the common telecomputing environment. We realize the sharing method with multimedia data to improve the coworking effect using teleprocessing network. This sharing method advances the efficiency of communicating projects such as remote education, tele-conference, and co-authoring of multimedia contents by offering conveniences of presentation, group authoring, common management, and transient event productions of the users. As for the conventional sharing white board system, all the multimedia contents segments should be authored by the exclusive program, and we cannot use any existing contents or program. Moreover we suffer from the problem that ordering error occurs in the teleprocessing operation because we do not have any line-up technology for the input ordering of commands. Therefore we develop a method of retrieving input and output events from the windows system and the message hooking technology which transmits between programs in the operating system In addition, we realize the allocation technology of the processing results for all sharing users of the distributed computing environment without any error. Our sharing technology should contribute to improve the face-to-face coworking efficiency for multimedia contents authoring, common blackboard system in the area of remote educations, and presentation display in visual conference.

  • PDF