• Title/Summary/Keyword: 정량평가방법

Search Result 2,615, Processing Time 0.029 seconds

Assessment of Both Standard and Isolated Vibrio parahaemolyticus on Efficacy of Commercial Sanitizers and Disinfectants (Vibrio parahaemolyticus 표준 및 식품분리 균주에 대한 살균소독제 유효성분별 감수성 평가)

  • Kim, Il-Jin;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Ha, Sang-Do
    • Journal of Food Hygiene and Safety
    • /
    • v.22 no.2
    • /
    • pp.127-131
    • /
    • 2007
  • This study evaluated the bactericidal effect of 10 sanitizers and disinfectants such as ethanol (75 and 95%), iodine (15 and 25 ppm), chlorine (100 and 200 ppm), quaternary ammonium, acid, hydrogen peroxide, and peroxide acetic acid against V. parahaemolyticus. Ten strains of V. parahaemolyticus isolated from Korean foods and 4 strains of standard V. parahaemolyticus were compared for efficacies of various sanitizers and disinfectants by EN 1276 method based on quantitative suspension test. Ethanol (75 and 95%), 25 ppm of iodine, 100 ppm of quaternary ammonium, 145 ppm of hydrogen peroxide and acid showed more than $5log_{10}CFU/mL$ reduction in both clean and dirty conditions. Tests result of chlorine (100 ppm) showed more than $5log_{10}CFU/mL$ reduction in clean condition. Iodine (15 ppm) showed more than $5log_{10}CFU/mL$ reduction except 4 isolated and 1 standard V. parahaemolyticus in clean condition. iodine (15 ppm) also showed under $5log_{10}CFU/mL$ reduction $(0.93{\sim}3.73log_{10}CFU/mL)$ in dirty condition. Eleven hundred ppm of hydrogen peroxide was evaluated as weak sanitizer and disinfectant due to their $0.99{\sim}4.79log_{10}CFU/mL$ reduction on both clean and dirty conditions. Consequently, ethanol, iodine (25 ppm), chlorine (200 ppm), quaternary ammonium, acid and peroxide acetic acid were thought to be effective sanitizer and disinfectant against V. parahaemolyticus.

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

Study of Disclusion Time during Mandibular Eccentric Movement in Myofascial Pain Syndrome Patients by T-Scan II, Computerized Occlusal Analysis System (컴퓨터 교학분석기인 T-Scan II를 이용한 측방운동시 구치부 이개시간에 관한 연구)

  • Shin, Jun-Han;Kwon, Jeong-Seung;Kim, Seong-Taek;Park, Hyung-Uk;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.187-197
    • /
    • 2011
  • Temporomandibular disorders(TMD) is a collective term which is embracing a number of clinical problems that involve the masticatory musculature, the TMJ and associated structures, or both. Myofascial pain, which is a kind of masticatory muscle disorder of TMD, is the sensory, motor, and autonomic symptoms caused by myofascial trigger points. There has been some controversies regarding etiologies of TMD and MFP. Especially the issue of occlusal conditions has been a critical issue for long time. Despite much efforts, the results of studies regarding occlusal conditions were contradictory. These controversies might be mostly due to various factors resulting from the complex nature of TMD, however, inaccurate and inappropriate study design, selection criteria, methodologies also play significant roles. Recently, a computerized occlusal analysis system, T-Scan II which made it possible to reveal quantifiable time data and relative force data for analyzing occlusion, was introduced. Some authorities suggested that the concept of disclusion time and prolonged disclusion time of posterior tooth and MFP are related using T-Scan II. But the previous studies which used T-SCAN II are not reliable for they did not provide accurate diagnostic criteria of MFP. Morever they did not compare with controls, and had many other problems. The purpose of this study was to evaluate the relationship between MFP and prolonged disclusion time of posterior tooth, which is one of the occlusal factors of TMD, by selecting 30 subjects as the study group through strict criteria and comparing them with 38 controls using T-SCAN II, computerized occlusal analysis system. The results, statistically analyzed, are summarized as follows: 1. Cronbach ${\alpha}$ coefficient of repeated measurements of disclusion time was 0.92. 2. There were no statistically significant differences at repeated measured disclusion time of both side between control and study group. 3. There was no statistically significant diffefence in the disclusion time between right and left side. From the results above, we can suggest that there was no relationship between MFP and disclusion time, so irreversible treatments leading to the reduction of disclusion time for treating MFP would not be appropriate. However more controlled, large scaled study, which consider various occlusal factors, and quantification of symptoms using Helkimo index would be necessary in the future.

Introduction and Evaluation of the Production Method for Chlorophyll-a Using Merging of GOCI-II and Polar Orbit Satellite Data (GOCI-II 및 극궤도 위성 자료를 병합한 Chlorophyll-a 산출물 생산방법 소개 및 활용 가능성 평가)

  • Hye-Kyeong Shin;Jae Yeop Kwon;Pyeong Joong Kim;Tae-Ho Kim
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1255-1272
    • /
    • 2023
  • Satellite-based chlorophyll-a concentration, produced as a long-term time series, is crucial for global climate change research. The production of data without gaps through the merging of time-synthesized or multi-satellite data is essential. However, studies related to satellite-based chlorophyll-a concentration in the waters around the Korean Peninsula have mainly focused on evaluating seasonal characteristics or proposing algorithms suitable for research areas using a single ocean color sensor. In this study, a merging dataset of remote sensing reflectance from the geostationary sensor GOCI-II and polar-orbiting sensors (MODIS, VIIRS, OLCI) was utilized to achieve high spatial coverage of chlorophyll-a concentration in the waters around the Korean Peninsula. The spatial coverage in the results of this study increased by approximately 30% compared to polar-orbiting sensor data, effectively compensating for gaps caused by clouds. Additionally, we aimed to quantitatively assess accuracy through comparison with global chlorophyll-a composite data provided by Ocean Colour Climate Change Initiative (OC-CCI) and GlobColour, along with in-situ observation data. However, due to the limited number of in-situ observation data, we could not provide statistically significant results. Nevertheless, we observed a tendency for underestimation compared to global data. Furthermore, for the evaluation of practical applications in response to marine disasters such as red tides, we qualitatively compared our results with a case of a red tide in the East Sea in 2013. The results showed similarities to OC-CCI rather than standalone geostationary sensor results. Through this study, we plan to use the generated data for future research in artificial intelligence models for prediction and anomaly utilization. It is anticipated that the results will be beneficial for monitoring chlorophyll-a events in the coastal waters around Korea.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

The CH3CHO Removal Characteristics of Lightweight Aggregate Concrete with TiO2 Spreaded by Low Temperature Firing using Sol-gel Method (Sol-gel법으로 이산화티탄(TiO2)을 저온소성 도포시킨 경량골재콘크리트의 아세트알데히드(CH3CHO) 제거 특성)

  • Lee, Seung Han;Yeo, In Dong;Jung, Yong Wook;Jang, Suk Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2A
    • /
    • pp.129-136
    • /
    • 2011
  • Recently studies on functional concrete with a photocatalytic material such as $TiO_2$ have actively been carried out in order to remove air pollutants. The absorbtion of $TiO_2$ from those studies is applied by it being directly mixed into concrete or by suspension coated on the surface. When it comes to the effectiveness, the former process is less than that of the latter compared with the $TiO_2$ use. As a result, the direct coating of $TiO_2$ on materials' surface is more used for effectiveness. The Surface spread of it needs to have a more than $400^{\circ}C$ heat treat done to stimulate the activation and adhesion of photocatalysis. Heat treat consequently leads hydration products in concrete to be dehydrated and shrunk and is the cause of cracking. The study produces $TiO_2$ used Sol-gel method which enables it to be coated with a low temperature treat, applies it to pearlite using Lightweight Aggregate Concrete fixed with a low temperature treat and evaluates the spread performance of it. In addition to this, the size of pearlite is divided into two types: One is 2.5 mm to 5.0 mm and the other is more than 5.0 mm for the benefit of finding out the removal characteristics of $CH_3CHO$ whether they are affected by pearlite size, mixing method and ratio with $TiO_2$ and elapsed time. The result of this experiment shows that although $TiO_2$ produced by Sol-gel method is treated with 120 temperature, it maintains a high spread rate on the XRF(X ray Florescence) quantitative analysis which ranks $TiO_2$ 38 percent, $SiO_2$ 29 percent and CaO 18 percent. In the size of perlite from 2.5 mm to 5.0 mm, the removal characteristic of $CH_3CHO$ from a low temperature heated Lightweight concrete appears 20 percent higher when $TiO_2$ with Sol-gel method is spreaded on the 7 percent of surface. In other words, the removal rate is 94 percent compared with the 72 percent where $TiO_2$ is mixed in 10 percent surface. In more than 5.0 mm sized perlite, the removal rate of $CH_3CHO$, when $TiO_2$ is mixed with 10 percent, is 69 percent, which is similar with that of the previous case. It suggests that the size of pearlite has little effects on the removal rate of $CH_3CHO$. In terms of Elapsed time, the removal characteristic seems apparent at the early stage, where the average removal rate for the first 10 hours takes up 84 percent compared with that of 20 hours.

The Usefulness of Scintigraphy for the Detection of Gastroesophageal Reflux and Pulmonary Aspiration (위식도 역류와 폐 흡인 진단 방법으로서 위식도 역류 신티그래피의 유용성)

  • Kang, Sung-Kil;Hyun, In-Young;Lim, Dae-Hyun;Kim, Jeong-Hee;Son, Byong-Kwan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.11 no.1
    • /
    • pp.12-20
    • /
    • 2008
  • Purpose: Chronic pulmonary disease may be caused by aspiration of gastric contents secondary to gastroesophageal reflux. At present, there is no gold standard for documenting pulmonary aspiration. The purpose of this study was to investigate the usefulness of radionuclide scintigraphy in the detection of gastroesophageal reflux and pulmonary aspiration. Methods: Thirty-five patients with suspected aspiration pneumonia, and five normal control subjects, were included in the study. All subjects underwent gastroesophageal reflux scintigraphy after the ingestion of a $^{99m}Tc$-tin colloid mixture. Dynamic images to detect gastroesophageal reflux were obtained for 1 hour. Additional static images of the chest, to detect lung aspiration, were obtained at 6 and 24 hours after oral ingestion of the tin colloid. In addition to visual analysis, pulmonary aspiration was quantitated by counting the number of pixels labeled with radioactive isotope in the region of interest (ROI) of both lung fields. Aspiration index (AI) was obtained by subtracting the pixel counts of the background from the pixel counts of the ROI. Results: Among 35 patients with suspected aspiration pneumonia, 23 proved to have gastroesophageal reflux by scintigraphy. One patient showed definite pulmonary accumulation of activity by visual analysis of the 6-hour image. Thirty of 35 (85.7%) patients showed higher AI beyond the upper limit of AI in the healthy controls. When we compared the reflux group with the non-reflux group, there was a significantly higher AI at 6 hours in the reflux group (p<0.05). Conclusion: The results suggest that radionuclide scintigraphy is useful in detecting small pulmonary aspiration in patients with suspected aspiration pneumonia secondary to reflux.

  • PDF

Imaging of Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression with Radiolabeled 5-(2-iodovinyl)-2'-deoxyuridine (IVDU) in liver by Hydrodynamic-based Procedure (Hydrodynamic-based Procedure를 이용한 간에서의 HSV1-tk 발현 확인을 위한 방사표지 5-(2-iodovinyl)-2'-deoxyuridine (IVDU)의 영상연구)

  • Song, In-Ho;Lee, Tae-Sup;Kang, Joo-Hyun;Lee, Yong-Jin;Kim, Kwang-Il;An, Gwang-Il;Chung, Wee-Sup;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.468-477
    • /
    • 2009
  • Purpose: Hydrodynamic-based procedure is a simple and effective gene delivery method to lead a high gene expression in liver tissue. Non-invasive imaging reporter gene system has been used widely with herpes simplex virus type 1 thymidine kinase (HSV1-tk) and its various substrates. In the present study, we investigated to image the expression of HSV1-tk gene with 5-(2-iodovinyD-2'-deoxyuridine (IVDU) in mouse liver by the hydrodynamicbased procedure. Materials and Methods: HSV1-tk or enhanced green fluorescence protein (EGFP) encoded plasmid DNA was transferred into the mouse liver by hydrodynaminc injection. At 24 h post-injection, RT-PCR, biodistribution, fluorescence imaging, nuclear imaging and digital wholebody autoradiography (DWBA) were performed to confirm transferred gene expression. Results: In RT-PCR assay using mRNA from the mouse liver, specific bands of HSV1-tk and EGFP gene were observed in HSV1-tk and EGFP expressing plasmid injected mouse, respectively. Higher uptake of radiolabeled IVDU was exhibited in liver of HSV1-tk gene transferred mouse by biodistribution study. In fluorescence imaging, the liver showed specific fluorescence signal in EGFP gene transferred mouse. Gamma-camera image and DWBA results showed that radiolabeled IVDU was accumulated in the liver of HSV1-tk gene transferred mouse. Conclusion: In this study, hydrodynamic-based procedure was effective in liver-specific gene delivery and it could be quantified with molecular imaging methods. Therefore, co-expression of HSV1-tk reporter gene and target gene by hydrodynamic-based procedure is expected to be a useful method for the evaluation of the target gene expression level with radiolabeled IVDU.

Perspective on Rapid and Selective Method for Detecting Microbiology in Dairy Industry: A Review (낙농산업에 필요한 미생물 검사방법과 전망: 총설)

  • Chon, Jung-Whan;Kim, Hyun-Sook;Kim, Hong-Seok;Kim, Dong-Hyeon;Song, Kwang-Young;Yim, Jin-Hyuk;Choi, Dasom;Lim, Jong-Soo;Jeong, Dong-Gwan;Kim, Soo-Ki;Seo, Kun-Ho
    • Journal of Dairy Science and Biotechnology
    • /
    • v.33 no.2
    • /
    • pp.119-127
    • /
    • 2015
  • To date, detection of microbial populations in dairy products has been performed using culture media, which is a time-consuming and laborious method. The recently developed chromogenic media could be more rapid and specific than classical culture media. However, the newly developed molecular-based technology can detect microbial populations with greater rapidity and sensitivity than the classical method involving culture media and chromogenic media. This molecular-based technology could provide various options for monitoring the characterization of different states of bacteria and cells. Thus, it could help upgrade the processing system of the dairy industry so as to maintain the safety and quality of dairy foods. Among the various newly developed molecular-based technologies, flow cytometry can potentially be used for monitoring microbiological populations in the dairy industry if official international standards are available for this purpose. When omics technology would have biomarker identification, it could be regarded as the rapid and sensitive analytical methods. Methods based on PCR, which has become a basic technique in microbiological research, can be developed and validated as alternative methods for quantification of dairy microorganisms. This review discusses methods for monitoring microbiological populations in dairy foods and the limitations of these studies, as well as the need for further research on such methods in the dairy industry.

  • PDF

Effect of moisture on sealing ability of root canal filling with different types of sealer through the glucose penetration model (수종의 실러를 이용한 근관 충전 시 근관 내 수분이 치근단 폐쇄효과에 미치는 영향)

  • Jang, Jin-Ah;Kim, Hee-Lyang;Her, Mi-Ja;Lee, Kwang-Won;Yu, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.5
    • /
    • pp.335-343
    • /
    • 2010
  • Objectives: To compared the effect of different levels of moisture of root canal on the sealing ability after filling with four different types of sealer. Materials and Methods: Single-rooted teeth (n = 90) instrumented to and apical size of 0.06 / 45 were randomly assigned to 12 experimental groups (n = 7 per group), positive/negative control groups (n = 3 per group). The teeth of the experimental groups (a. DRY; b. PAPER POINT DRY; c. WET) were obturated with sealer (Group 1-3: Sealapex; Group 4-6: AH plus; Group 7-9: Tubuli-seal; Group 10-12: EndoRez) and warm vertical compaction method. After 7 days in $37^{\circ}C$, 100% humidity, the coronal-to-apical microleakage was evaluated quantitatively using a glucose leakage model. The leaked glucose concentration was measured with spectrophotometer at 1, 3, 7, 14, 21, and 30 days. Data were recorded ad mmol/L and statistically analysed with the two-way ANOVA and Duncan test (p = 0.05). Results: Throughout the experimental period Tubuli-seal/WET (Group 9) showed the highest mean cumulative glucose penetration (178.75 mmol/L), whereas AH plus/DRY (Group 4) had the least (20.78 mmol/L). Conclusions: The results of this study demonstrated that the moisture condition of root canals at the time of obturation and the type of sealer that was used had a significant effect on leakage and sealing ability. Thus drying procedure according to sealer types is a critical step and should not be missed in endodontic treatment.