• Title/Summary/Keyword: 정격

Search Result 699, Processing Time 0.035 seconds

Robust Design Optimization for Reducing Cogging Torque of a BLDC Motor through an Enhanced Taguchi Method (개선된 다구찌 기법을 이용한 BLDC 전동기의 코깅 토크 저감을 위한 강건 최적설계)

  • Lee, Chang-Uk;Kim, Dong-Wook;Kim, Dong-Hun
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.160-164
    • /
    • 2014
  • In this paper, an efficient robust design utilizing an enhanced Taguchi method is proposed to reduce cogging torque of a BLDC motor in the presence of design uncertainty. To overcome defects of the conventional Taguchi method in dealing with a generalized robust design problem, a penalty function and an optimal level searching technique are newly introduced. In order to verify the proposed method, a 5 kW, rated speed of 2,300 rpm, rated torque of 20 Nm BLDC motor for driving electric vehicles is optimized. Then, the robust design is compared with conceptual and deterministic ones in terms of the cogging torque, rated torque and torque ripple.

A Case Report of Otitis Media in Three Children Treated with the Sa-Am Acupuncture Bi-Jung-Geouk(脾正格) and Bojoong-Ikgi-Tang(補中益氣湯) (사암침법(舍岩鍼法)의 비정격(脾正格)과 보중익기탕(補中益氣湯) 복합치료를 통한 소아 중이염환자 치험 3례(例))

  • Lee, Sang-Ryong;Hong, Seung-Won
    • Korean Journal of Acupuncture
    • /
    • v.23 no.1
    • /
    • pp.125-135
    • /
    • 2006
  • Obiectives : Otitis media is the disease which indicates every inflammatory situation in the middle ear. This includes the inflammation in the ear canal and mastoid sinus. In this study, the effect of Sa-Am acupuncture Bi-Jung-Geouk(脾正格) and Bojoong-ikgi-tang(補中益氣湯) for three children patients with otitis media were evaluated. Methods : After treatment with the Sa-Am acupuncture Bi-Jung-Geouk(脾正格) and Bojoong-ikgi-tang(補中益氣湯) for 3~6 weeks, we evaluated the effect by the figure of otoscope and complaints of patients. Results : In three cases, the pus in the figure declined dramatically and symptoms of patients got better after 3~6 weeks treatment. Conclusions : The Sa-Am acupuncture Bi-Jung-Geouk(脾正格) and Bojoong-ikgi-tang(補中益氣湯) for otitis media was effective. It will be attempted to the patients with it.

  • PDF

A Study on the External Fault Performance Evaluation of Grid-Connected Power Conditioning System for Residential Fuel Cell System (가정용 연료전지시스템 계통연계형 전력변환장치의 외부사고 성능평가에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.131-131
    • /
    • 2009
  • 최근 환경규제가 강화되면서 친환경적인 전력생산 요구 등의 외부환경 변화에 따른 우리나라의 전력구조가 기존의 중압 집중형 발전을 탈피한 분산전원 발전에 대한 관심이 증대되고 있는 실정이다. 특히, 분산전원으로서의 전력생산은 공급의 안전성, 경쟁력 및 에너지의 지속성 등이 요구되어지는데, 재생에너지가 가지고 있는 에너지 지속성의 한계 및 설치의 제약성을 탈피할 수 있는 시스템으로 현재 연료전지시스템이 가장 근접해 있는 실정이다. 즉, 도시가스 인프라가 우수하고 인구조밀 지역이 많은 우리나라의 특성상 각 가정 및 건물에 쉽게 설치하고 공급의 안전성을 갖는 건물용 연료전지는 최근 가장 각광받고 있는 분산전원 시스템 중의 하나이다. 올해부터 모니터링사업의 일환으로 수용가에 설치 될 연료전지 시스템이 얼마나 안정적으로 전기와 열을 각 가정에 공급하고 시스템의 안전성을 확보하는 가는 건물용 연료전지의 분산전원으로서의 가능성 및 국민의 수용성을 증대시키는 중요한 역할을 할 것이다. 연료전지시스템은 상용전력과 연계되어 있기 때문에 시스템의 안정성 뿐만 아니라 상용전력의 변화에 대응하여 안정적인 운전을 하는지에 대한 평가가 필수적이다. 이에 따라 본 연구에서는 가정용 연료전지시스템의 성능 및 안전성평가의 일환으로 계통연계형 전력변환장치의 성능 및 안전성을 평가 하고자 한다. 연료전지 검사를 위한 계통연계형 전력변환장치의 시험평가 항목으로는 크게 정상특성성능시험, 보호기능성능시험, 과도응답특성성능시험 및 외부사고성능시험 등으로 나뉘어진다. 본 연구에서는 외부사고 성능시험 항목들인 출력측 단락시험, 계통전압 순간정전?순간강하시험 및 부하차단 시험 등을 통하여 외부사고에 대한 성능 및 안전성을 평가하였다. 외부사고 성능시험의 주 목적은 시스템의 이상 운전이 아니라 외부의 영향에 따른 시스템의 안전성 및 전력품질을 평가한다. 출력측 단락시험을 수행하기 위해서 전력변환장치를 정격 출력 전압, 정격 출력 주파수 및 정격 출력에서 운전한 후, 교류 전원장치는 단락 전류를 검출하여, 사고 발생 후 0.3초 이내에 개방하도록 설정하였다. 여기서, 단락 저항 Rsc를 정격 전류의 10배 이상에 해당하는 부하와 같은 값으로 설정하였다. 스위치 SWSC를 폐로하여 단락 상태를 만들며, 이 때 전력변환장치의 출력전류와 차단 또는 정지 시간을 측정하였다. 실험 결과에 대한 판정기준은 단락전류를 검출하여 0.5초 이내에 개폐기 개방 또는 게이트 블록 기능이 동작하여 시스템을 안정하게 정지시키고 시스템 어떤 부위에도 손상이 없어야 한다. 실험 결과 파워컨디셔너의 출력전류 및 차단 또는 정지된시간이 40ms로 나타났고, 출력전류의 파형도 매우 안정함을 볼 수 있었다. 이와 같이 모든 실험을 수행한 결과 외부사고에 대하여 시스템이 안전하게 정지하는 등 연료전지 시스템의 안전성을 확인하였다.

  • PDF

Analysis of the Melting Characteristics of a Blade Type Fuse Used for Vehicles Due to Overload (과부하에 따른 차량용 블레이드형 퓨즈의 용단특성 해석)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.38-43
    • /
    • 2010
  • The purpose of this study is to secure the basis for judgment on the cause of an accident by analyzing the melting characteristics of a blade type fuse used for vehicles due to overload. In order to increase the reliability of the test, it was conducted by connecting the electrical system with conditions similar to those of an actual vehicle to apply the load. Carbonization pattern experiment of fuse by outside flame applied Korean Standard (KS). The fuse melted by the overcurrent showed a smooth cross-section while the test terminals, clear plastic body, etc., burnt out by the external flame was badly deformed. When 185% of the rated current (27.8A) was applied to a cable of 15A rated current onto which an over-capacity fuse (20A) was installed, the fuse melting time was 217 seconds. In addition, when a load current of 28.8[A] (139%) was applied, the fuse's test terminal and terminal blade were not burnt out although foam was observed on some parts of the plastic body. When a load capacity of 28.2[A] (141%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melting time was approximately 10 seconds. When a load current of 35.8[A] (119%) was applied, the fuse's test terminal and terminal blade were not burnt out, although some parts of the plastic body was swelled. However, it was observed that the switch terminal melted if approximately six minutes lapsed under such conditions. When a load capacity of 39.4[A] (131%) was applied to a cable of 15A rated current onto which an over-capacity fuse (30A) was installed, the fuse melted in approximately 69 seconds, and the test terminal and terminal blade were not burnt.

전기설비의 검사 점검 및 시험 [18]

  • Gwon, Sun-Gu;Kim, Gi-Uk;Lee, Gyu-Bok
    • Electric Engineers Magazine
    • /
    • v.257 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • 나. 계기용 변성기 - (1) PT의 경우 - 그림1·59단자간 저항측정으로 단선이나 단란이 아닌 것이 확실하면 <그림1·59>와 같이 고압측 끼리 접속하고, 한쪽의 저압측에서 전압조정기를 통하여 전압을 가하고, 이 전압과 다른쪽의 저압측 전압을 비교한다. 대략 정격전압까지 더하여 양편의 전압계의 차가 1~2%이면 문제없다. (중략)

  • PDF

Software development for Auto Design of permanence magnet electrical machine (영구자석 전기기기의 자동 설계를 위한 특성해석 소프트웨어 개발)

  • Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2269_2270
    • /
    • 2009
  • 본 논문에서는 비주얼베이직을 이용하여 영구자석 전기기기의 제량을 자동으로 설계를 할 수 있는 소프트웨어를 개발하는데 필요한 이론을 제시하였다. 설계에 필요한 기본적인 기기의 용량과 정격전압, 회전속도 등의 값만 입력하여 전동기의 제량을 계산 할 수 있는 프로그램을 개발하였다.

  • PDF

전기화재 원인과 발생⑨

  • 김미승
    • Electric Engineers Magazine
    • /
    • v.251 no.7
    • /
    • pp.24-27
    • /
    • 2003
  • 전열기 및 전기의 발열작용을 이용한 전기기기에는 정격용량 및 허용용량에 맞는 저항기 및 온도제어장치를 이용하여 전기사용기기에 허용전류이상 또는 허용용량 이상의 전류가 흐르지 못하게 하는데 이들 저항기 및 온도제어장치 고장 및 구조적 결함으로 과부하 형태가 나타날 수 있다.

  • PDF

Switching Performance of 3.3kV HVIGBTs with PT and NPT Structures (PT와 NPT 구조를 가진 3300V HVIGBT 스위칭 특성 비교 연구)

  • 엄기주;서범석;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.201-205
    • /
    • 1999
  • 이 논문은 3300V 정격의 PT와 NPT HVIGBT의 스위칭 특성을 비교하여 제시한다. 실제적인 응용을 고려하여 hard 스위칭 조건에서 실험하여 얻어진 데이터 수치들을 보인다. 이 비교 평가가보다 나은 스위칭 특성들을 얻기 위한 기반이 될 수 있을 것이다.

  • PDF

The Study of the Dynamic Breaking of the DC Motor (직류 전동기의 동적 제동에 대한 연구)

  • 서주하
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.4 no.4
    • /
    • pp.52-60
    • /
    • 1990
  • 회수되는 에너지가 적거나 제동이 빈번하지 않은 시스템에서는 동적 제동이 적합하다. 본 논문에서는 제어 가능한 스위치를 하나만 사용한 여러회로중 전류의 연속성, 회로의 간단성, 정격보다 큰 전압에서의 스위치 전압 등을 비교 분석하여 간단하면서도 효율적인 회로를 선택 제안하였다. 실험을 통해 제안된 회로가 만족할만한 결과를 보였다.

  • PDF

피뢰기 정격과 절연협조 I

  • Lee, Seong-U
    • Electric Engineers Magazine
    • /
    • s.275
    • /
    • pp.21-27
    • /
    • 2005
  • 피뢰기란 뇌서지 및 개폐서지로 인한 과도적 이상전압으로부터 전력설비의 기기를 보호하는 장치이다. 종래에는 주로 전력시설물을 그 보호대상으로 하고 있었으나 최근에는 건축물의 내부에 사용하는 정보통신기기를 보호하는 기술도 발달하고 있다. 본 론에서는 고압기기를 보호대상으로 하는 피뢰기에 대하여 살펴보겠다.

  • PDF