• Title/Summary/Keyword: 접합부 성능

Search Result 546, Processing Time 0.035 seconds

Seismic Performance Evaluation of Post-Northridge WUF-B Connections Frame (Post-Northridge WUF-B 접합부 골조의 내진 성능 평가)

  • Han, Sang Whan;Moon, Ki Hoon;Jung, Ji Eun;Lee, Ki Hak
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.751-760
    • /
    • 2007
  • The purpose of this study is to evaluate the seismic performance of the frame which is assumed to be used with Welded Unreinforced Flange-Bolted web (WUF-B) connections and detailed in compliance with FEMA 350 recommended seismic design criteria. In FEMA 350, these types of connections are only valid for Ordinary Moment-Resisting Steel Frames (OMRSFs). For this purpose, based on test results, we proposed an analytical model for the Post-Northridge WUF-B connections with different panel zone strength ratios. Using the connection model, SAC Phase II three and nine-story frames were modeled and analyzed. From a nonlinear static pushover analysis, ductility, maximum strength, and the maximum interstory drift ratio were investigated for buildings with Post-Northridge details. Moreover, the maximum interstory drift ratio of each performance level (IO and CP) was also investigated through Incremental Dynamic Analysis (IDA). Analytical results were compared with those of buildings with either Pre-Northridge connection or ductile connections with no fracture. The analytical results showed that buildings with Post-Northridge WUF-B connections provide superior strength and interstory drift ratio capacity than buildings with Pre-Northridge WUF-B connections.

Load-Displacement Characteristics and Interactive Load Capacity Model for Metal Plate Connections in Wood(II) - Interactive Load Capacity Model and Experimental Verification - (목재(木材)-금속(金屬)플레이트 접합부(接合部)의 하중(荷重)-변위(變位) 특성(特性) 및 조합하중성능(組合荷重性能)에 대한 모형 분석 (II) - 조합하중모형(組合荷重模型)과 실험적(實驗的) 입증(立證) -)

  • Park, Moon-Jae;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.12-18
    • /
    • 1995
  • 고도(高度)의 엔지니어링 구조물(構造物)로 경제성이 높은 경량(輕量) 목조(木造)트러스에 사용될 수 있는 소나무(Pinus densiflora) 재(材)에 적용한 20게이지 아연도금 강(鋼) 플레이트 접합부(接合部)의 조합하중(組合荷重) 및 모멘트 성능(性能)을 평가하기 위하여 정밀도를 개선(改善)한 편심가력(偏心加力) 장치(裝置)를 창안하여 실험하고 반강절(半剛節) 접합부의 개념(槪念)과 가상(假想)일 법(法)을 적용한 모형을 유도하여 비선형(非線形) 해석(解析)하였다. 반강절(半剛節) 접합부(接合部)의 개념을 도입하여 저자가 유도한 비선형(非線形) 모형으로 조합하중 하에서의 접합부 거동을 해석한 결과, 금속 플레이트 접합부의 모멘트는 Wolfe 모형에 비하여 정확도가 높은 값으로 계산되었는데, 이는 비선형모형에서 접합부의 반강성(半剛性)에 의한 2차적인 모멘트의 영향을 적절히 고려한 때문으로 판단되었다. 본 연구에서 사용한 실험장치는 조합하중에 대한 금속 플레이트 접합부의 성능을 평가하기 위한 표준시험법(標準試驗法)으로 적용될 수 있을 것이며, 비선형(非線形) 해석방법(解析方法)은 조합하중(組合荷重)및 모멘트 성능(性能)을 예측(豫測)하는데 활용될 수 있다.

  • PDF

Improvement and Evaluation of Seismic Performance for Reinforced Concrete Beam-Column Joints Using High Performance Embedded FRP (고성능 FRP를 활용한 철근콘크리트 보-기둥 접합부의 내진 성능 평가 및 개선)

  • Ha, Gee-Joo;Shin, Jong-Hack;Kang, Hyun-Wook
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.385-392
    • /
    • 2011
  • In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (steel plate, carbon fiber sheet, and embedded carbon fiber rod) in existing reinforced concrete buildings. Six specimens of retrofitted beam-column joints are constructed using various retrofitting materials and tested for their retrofit performances. Specimens designed by retrofitting the beam-column joint regions (LBCJ series) of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the effect of crack control at the time of initial loading and confinement from retrofitting materials during testing. Specimens of LBCJ series, designed by the retrofitting of FRP in reinforecd beam-column joint regions increased its maximum load carrying capacity by 26~50% and its energy dissipation capacity by 13.0~14.4% when compared to standard specimen of LBCJC with a displacement ductility of 4.

Seismic Performance of Composite Beam-to-Column Joints Using Wedges (쐐기의 원리를 이용한 합성 보-기둥 접합부의 내진성능에 관한 연구)

  • Park, Jong-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.6
    • /
    • pp.63-68
    • /
    • 2007
  • The purpose of this study was to develop a new connection method between steel beams and PC columns known as SL connectors. Composite moment frames consisting of PC columns (or composite columns) and steel beams make the best use of advantages of both concrete and steel materials. However, the connection between two members of different materials can be complex and/or increase the fabrication costs significantly. The concept of SL connectors is based on using wedges and the emphasis is on a self-locking (SL) feature. SL connectors are easy to install and provide better seismic performance compared to conventional connections. To evaluate the seismic performance of the steel beam-to-PC column joints with SL connectors, cyclic load tests were conducted. Test result showed that steel beam-to-concrete column joint with SL connectors was able to provide sufficient performance for use in seismic resistant moment frames.

The Structural Performance of PSC Frame System with GerberCs beam (게르버 보 형식의 PSC 골조시스템의 구조성능)

  • Kim, Sang-Sik;Choi, Kwang-Ho;Lee, Jong-Gyu;Song, Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.341-346
    • /
    • 2002
  • 이 연구는 게르버 보 형식의 포스트텐션 PC 골조 구조 시스템의 실용화를 위해 골조 전체의 구조 성능 시험을 수행하며, 여기서 보-기둥 접합부 및 내민 보-단순 보 접합부의 구조 성능과 골조의 안전성을 확인한다. 시험은 400 mm$\times$800 mm 단면의 경간 3 m 보와 500 mm$\times$600 mm 단면을 갖는 높이 3 m 기둥의 실물 크기 시험체를 제작하여, 기둥에 80 톤의 축 하중을 준 상태에서 단순 보 중앙에 하중을 가력하여 기둥-보 접합부와 단순 보-내민 보 단면 축소 연결부의 구조성능을 파악한다. 시험 결과, 보 - 기둥 접합부는 예상 설계 하중 40톤 이상에서도 강 접합에 가깝게 거동하였고, 단순 보- 내민 보의 단면 축소 연결부는 경사철근의 사용으로 초기 균열 및 균열 확산에 대한 억제 효과가 있었으며, 예상 설계 전단력 40톤에서 안전하다는 것이 확인되었다.

  • PDF

Structural Performance and CO2 Reduction Evaluation of the Ultra simple Wide-shaped section Beam-to-Column Weak Axis Connection (초간편 H형강 기둥-보 약축접합부의 구조성능 및 CO2 저감량 평가)

  • Kim, Sang-Seup;Boo, Yoon-Seob
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.5
    • /
    • pp.615-627
    • /
    • 2011
  • There have been few researches on the connection technology for steel structures, so the research outputs and the outcome of the technology development are still insufficient. The bracket-type connection should be improved for efficient constructability and $CO_2$ reduction. It should be replaced by a new type of weak-axis connection that has better structural performance and less $CO_2$ emission. Since the structural performance and safety of the new type of weak-axis connection must first be verified, however, a study on $CO_2$ reduction will be conducted. Therefore, this study looked into the structural performance of the bracket-type details, standard details, and ultra-simple details. It evaluated the requirements for connection materials and $CO_2$ emission. It was found that the ultra-simple weak-axis connection has thebest structural performance and the least $CO_2$ emissions, so it is deemed capable of replacing the bracket-type weak-axis connection.

Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction (경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능)

  • Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.3
    • /
    • pp.211-220
    • /
    • 2013
  • The nailed joints in wood construction are commonly designed to resist and carry the lateral load but also subject to withdrawal force like uplift load due to the wind. This research was conducted to evaluate the performance of nailed joint composed of dimension lumber and sheathing materials through the nail withdrawal and unsymmetric double shear joint test, and then compared to current design values. The withdrawal strength was greatly dependant on wood specific gravity, and the withdrawal strength of I-joist with OSB showed higher value in spite of low specific gravity. The maximum withdrawal loads were greater than that of derived current design values about 5 times. The lateral resistance of Japanese larch/OSB nailed joints was higher than that of SPF/OSB nailed joint, and derived allowable lateral strength of nailed joints in this study exceeded the current design values. The failure mode of nailed joints was primarily due to the nail bending and this tendency was notable in SPF/OSB nailed joint.

Panel Zone Behavior of Steel Box Connections (Box단면 접합부의 Panel Zone 거동특성)

  • Hwang, Won Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.683-695
    • /
    • 1997
  • This paper presents the shear behavior of panel zone in steel frame piers. The results of loading tests on twenty box connections and three types of analysis model are reported herein. It is indicate that the major cause of the reduction of strength and shear deformation capacity (ductility) is the sectional-area ratio and the shear buckling of panel zone. Based on the results, some new proposals are presented for the evalution of strength and ductility of panel zone. This paper is also discussed the ductility of connections by current design procedure.

  • PDF

Seismic Performance of Existing Welded Steel Moment Connections to Built-up Box Columns (기존 용접형 철골 박스기둥 접합부의 내진성능)

  • Kim, Tae-Jin;Stojadinovic, B.;Whittaker, A.S.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.1 s.47
    • /
    • pp.25-32
    • /
    • 2006
  • In this study the seismic performance of welded steel moment connections to built-up box columns in the existing building built before 1994 Northridge earthquake was evaluated by cyclic tests. According to the test results, the pre-Northridge steel moment connections to the box columns also suffered from brittle fracture similar to that in the H-shaped column connections. However, the flange force transfer mechanism of the box column connections was substantially different from that of the H-shaped column connections, and the patterns of crack propagation may be changed due to the shape of the box column. Therefore, it is required to develop proper details for the box column connections instead of using the research results for H-shaped column connections in order to enhance the seismic performance the connections.

An Experimental Research on the Shear Friction Behavior of Beam-Column Joints of Partial Precast Concrete Structures (부분PC 보-기둥 접합부의 전단 마찰 거동에 관한 실험 연구)

  • Kim, Sang-Yeon
    • Land and Housing Review
    • /
    • v.5 no.2
    • /
    • pp.91-97
    • /
    • 2014
  • An experimental program was initiated to investigate the structural capacity of PC (Precast Concrete) beam-column joints used for the underground parking structure. Static testing of 4 typical PC beam-column joints specimens was conducted. Specimens were designed to span a range of parameters typically encountered for such members, based on findings from the survey of existing PC joint details used in the construction fields in Korea. The specimens were four by their joint types and testing parameters. The specific structural behavior germane to each specimen, and general observations on overall member behavior as a function of the considered parameters, are reported. From the results of tests on four PC joints specimens, the beam-column joints of PC structure used for the underground parking building was found to have similar structural capacities when comparing to the cast-in-place concrete system.