• Title/Summary/Keyword: 접촉식 형상 측정기

Search Result 12, Processing Time 0.02 seconds

Effects of stylus tip radius on the measuring error in surface topography measurement by contact stylus profilometer (접촉식 형상 측정기에 의한 표면 미세 형상 측정시 촉침 반경이 측정오차에 미치는 영향)

  • 권기환
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.613-617
    • /
    • 2000
  • This paper descries the effect of the stylus tip size on the measuring error in surface topography measurement. To analyze the distortional effect of an actual surface geometry originating from the finite stylus size, the surface is modeled as a sinusoid and the stylus tip as a circle. the measuring error is defined as the ratio of the standard deviation of a tracing profile and an original profile. It is shown that this measuring error depends on the amplitude and wavelength of an original profile. In this paper, the spectrum analysis is applied to investigate the distortional effect due to the mechanical filtering of the stylus in the frequency domain. and, the cumulative power spectrum is applied to determinate the minimum wavelength limits to be measured with the various stylus tip radius from these results, a new method to select proper stylus tip radius is proposed.

  • PDF

An Error Compensation in Rough Surface Measurement by Contact Stylus Profilometer (표면미세형상측정을 위한 접촉식 형상측정기의 오차 보정)

  • 조남규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.1
    • /
    • pp.126-134
    • /
    • 1999
  • In this paper, a new error compensating technique for form-error compensation of rough-surface profile obtained by contact stylus profilometer is proposed. By the method, the real contact points of rough-surface and diamond stylus can be estimated and the measured profile data corrected. To verify the compensation effect, the properties(Ra, RMS, Kurtosis, Skewness) of measured profile data and compensated data were compared. And, the cumulative RMS slope was proposed to assess the compensated effect of upper area of profile. The results show that the measuring error could be compensated very well in amplitude parameters and in proposed cumulative RMS slope by the developed form-error compensating technique.

  • PDF

The Study of reconstruction for 3D contact-measurement using TCP/IP communication (3차원 접촉식 측정기구의 네트웍을 통한 형상 복원에 관한 연구)

  • 고덕현;이순걸
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.3-7
    • /
    • 2000
  • The authors have realized reconstruction of 3D shape using contacting method with pins and TCP/IP communication. In this paper, the working principal of the mechanism is proposed and tested. A special sensor system is designed as 148 matrix form to measure 3D shape. When contact occurs between pin and the plate of the sensor matrix, the position information of pins is sent to computer and raised height data of the pin is obtained by counter which accumlates encoder signal. So, all datum which contain 3-dimensional coordinate, is transferred using TCP/IP communication. Finally, 3D shape is reconstructured by Web browser of remote computer. The measuring result shows that the proposed mechanism is reliable and promising as a remote measuring device through Internet.

  • PDF

Profile Error Measurement of a Turbine Blade Using a Contact Type 3D-Scanner (접촉식 3차원 형상스캐너를 이용한 터빈 블레이드의 형상 정밀도 측정)

  • Kang, Byung-Su;Kang, Jae-Gwan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.76-81
    • /
    • 2006
  • In this paper, profile error measurement method of a turbine blade using 3D-scanner is developed. The method begins with scanning the upper and lower sides of the blade on which three small balls are attached, and constructs a solid measurement model by registering the two scanned surfaces. Airfoils are derived from the model at each interval by intersecting it with a plane, and arranged with design airfoils. The $2^2$ factorial design search method is engaged in arranging the two airfoils, from which the main blade parameters including the edge radius are computed. The developed measurement technique is applied to practical blade manufacturing and validates its effectiveness.

A Study on the Performance of Atomic Force Probe for Coordinate Measuring Machines (3차원 측정기를 위한 원자간력 프로브 성능 연구)

  • Jung, P.G.;Bae, G.H.;Hong, S.W.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.75-80
    • /
    • 2008
  • This paper presents an atomic force probe for triggering coordinate measuring machines(CMMs). A rigorous comparison is made between touch trigger probe and atomic force probe for CMMs. Typical CMMs(touch trigger probe based CMMs) often lead to some errors associated with object curvature and difference in triggering sensitivity. Their applicability is limited only to hard objects. The aim of this work is to develop a trigger sensor for CMMs using atomic force. In order to show the applicability of atomic force as a trigger sensor, a cylindrical shape is measured with a CMM and an atomic force microscope. Three different touch probe heads with different ball sizes are tested. The experiments show that smaller ball provides better results for curved objects. The experimental results also show that the performance of atomic force as a trigger sensor is about that of the smallest ball probe. In addition, experiments are also performed to measure soft objects. Finally, this paper suggests and verifies a trigger sensor using atomic force for CMMs.

이온 보조 반응법을 이용한 상용 PVC의 친수성 증대

  • 한영건;조준식;최성창;고석근;김동환
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.199-199
    • /
    • 1999
  • 상용의 PVC가 갖는 소수 특성을 개선하기 위해 산소, 아르곤, 수소 이온의 이온 보조 반응법을 이용하여 표면의 친수성을 증대시키고 이때 친수성 증가의 직접적 원인인 표면에너지 증가를 각각의 이온조사에 따라서 비교하였다. 이온 소스는 직경 5-cm의 cold hollow cathod ion gun을 이용하였으며 산소, 아르곤, 수소이온을 이온 조사량 5$\times$1014~1$\times$1017ions/cm2까지 변화시키고 산소의 유량을 0~8sccm까지 변화시키면서 표면 에너지 변화를 관찰하였다. 표면 에너지는 두 가지의 극성 용매인 물과 포름아마이드의 접촉각을 정적 접촉각 측정기를 이용하여 측정한 후에 이로부터 dispersion force와 polar force를 계산하여 얻었다. 계산된 결과를 보면 처리 전과후의 dispersion force의 변화는 거의 없으나 polar force는 크게 증가하였다. 이때 표면 에너지의 증가는 표면 형상의 변화와 극성을 띠는 친수성기의 증가로 여겨지며 각각의 경우에 대한 분석을 위해 AFM과 XPS 분석을 시행하여 각각의 이온에 따르는 표면 형상의 변화와 친수성기의 형성 및 상대적인 양을 비교하였다.

  • PDF

Development of Hole Inspection Program using Touch Trigger Probe on CNC Machine Tools (CNC 공작기계 상에서 접촉식 측정 프로브를 이용한 홀 측정 프로그램 개발)

  • Lee, Chan-Ho;Lee, Eung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.2
    • /
    • pp.195-201
    • /
    • 2012
  • According to many customers' requests, optical measurement module (OMM) applications using automatic measuring devices to measure the machined part rapidly on a machine tool have increased steeply. Touch trigger probes are being used for job setup and feature inspection as automatic measuring devices, and this makes quality checking and machining compensation possible. Therefore, in this study, the use of touch trigger probes for accurate measurement of the machined part has been studied and a macro program for a hole measuring cycle has been developed. This hole is the most common feature to be measured, but conventional methods are still not free from measuring error. In addition, the eccentricity change of the least square circle was simulated according to the roundness error in a hole measurement. To evaluate the reliability of this study, the developed hole-measuring program was executed to measure the hole plate on the machine and verify the roundness error in the eccentricity simulation result.

Experimental Validation of Isogeometric Optimal Design (아이소-지오메트릭 형상 최적설계의 실험적 검증)

  • Choi, Myung-Jin;Yoon, Min-Ho;Cho, Seonho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.345-352
    • /
    • 2014
  • In this paper, the CAD data for the optimal shape design obtained by isogeometric shape optimization is directly used to fabricate the specimen by using 3D printer for the experimental validation. In a conventional finite element method, the geometric approximation inherent in the mesh leads to the accuracy issue in response analysis and design sensitivity analysis. Furthermore, in the finite element based shape optimization, subsequent communication with CAD description is required in the design optimization process, which results in the loss of optimal design information during the communication. Isogeometric analysis method employs the same NURBS basis functions and control points used in CAD systems, which enables to use exact geometrical properties like normal vector and curvature information in the response analysis and design sensitivity analysis procedure. Also, it vastly simplify the design modification of complex geometries without communicating with the CAD description of geometry during design optimization process. Therefore, the information of optimal design and material volume is exactly reflected to fabricate the specimen for experimental validation. Through the design optimization examples of elasticity problem, it is experimentally shown that the optimal design has higher stiffness than the initial design. Also, the experimental results match very well with the numerical results. Using a non-contact optical 3D deformation measuring system for strain distribution, it is shown that the stress concentration is significantly alleviated in the optimal design compared with the initial design.