• Title/Summary/Keyword: 접속전압강하

Search Result 7, Processing Time 0.029 seconds

Voltage Control of Power System Connected to a Wind Farm by Using STATCOM and Reactive Power Compensators (STATCOM과 조상설비를 이용한 풍력단지가 연계된 전력계통의 전압제어)

  • Seo, Gyu-Seok;Park, Ji-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2737-2743
    • /
    • 2015
  • The wind power plant must be able to produce reactive power at the POI bus of a wind farm connected to power system to keep or control the voltage of POI bus. But, the reactive power capability of wind turbines may not be sufficient to control the voltage of POI bus due to the reactive power losses in connection lines between wind farm and POI bus. The solution of this problem is to install an external STATCOM. The proposed cooperative control method of STATCOM and conventional reactive power compensators such as Switched-shunt and tap changing transformer can control the voltage of POI bus more efficiently. The simulation results are shown that the voltage drop of POI Bus of Test System with the arbitrary load change rate to initial loads is improved more than 60% and the voltage of load bus is maintained more than 95% of rated voltage.

A Study on Control Algorithm of a Switching Device for Junction of Photovoltaic Modules by Using Soft Starting (소프트 스타팅을 이용한 태양광모듈 접속장치용 스위칭 소자의 제어기법에 관한 연구)

  • Kim, Eun-Soo;Ha, Yong-Ho;Hwang, Seon-Hwan;Lee, Jaeseok
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.306-307
    • /
    • 2017
  • 본 논문에서는 태양광모듈과 전력변환장치간의 접속장치로 사용된 전력용 반도체 스위칭 소자의 소프트 스타팅 기법을 통해 초기 돌입전류를 저감하는 알고리즘을 제안하고자 한다. 태양광 모듈의 경우, 릴레이나 DC차단기 등을 사용하여 전력변환장치와 연동하는 것이 일반적이나, 이 경우 태양광모듈의 수명과 접속장치의 전압 강하 및 응답성 등의 문제를 야기한다. 또한, 전력변환장치 출력단의 커패시터에 초기 동작 시 과도한 동일전류가 발생하게 되고 이는 태양광모듈의 과전류 현상을 발생시켜 모듈의 수명과 더불어 퓨즈의 차단 및 발열 등 비이상적인 현상을 발생시킨다. 따라서, 본 논문에서는 이러한 문제점을 해결하고자 스위칭 소자를 사용한 접속장치 적용하였고, 소프트 스타팅 기법을 이용하여 돌입전류를 저감하고자 한다. 제안한 알고리즘의 경우, 시뮬레이션을 통해서 검증하고자 한다.

  • PDF

Development of High Voltage Pulse Power Supply for Gyroklystron Tube (Gyroklystron Tube 구동을 위한 고전압 펄스 전원장치의 설계 및 개발)

  • Park, Jae-An;Youn, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.71-73
    • /
    • 2000
  • 최근 고 에너지 저장 및 발생장치의 개발은 군사용에서 산업용으로 응용되면서 각종 첨단 설비가 개발되고 있다. 본 논문에서는 전자빔 발생기로 쓰이는 Gyroklystron용 대전력, 고전압, 전류 펄스 전원장치로 입력부, 특고압 발생부, 고압 정류부 및 IGBT 펄스 스위치 구성하고 그 설계 및 개발 자료에 대하여 기술하였다. 대전력 고전압 전류펄스 전원장치를 위한 각 구성 부분의 제어 및 설계 특징은 다음과 같다. 입력부인 IGBT Inverter는 펄스 전원장치의 제어를 위하여 출력 고전압을 Feedbark System에 의해 펄스 설정 전압을 유지하도록 제어하며, 또한 펄스 출력중에 직류 고전압부의 전압강하, 즉 펄스 진압의 Drop이 커지는 것을 방지하기 위하여 Fast Dynamics를 갖도록 Feedback System을 구성하였다. 단상 특고압 승압용 변압기 3대를 직렬접속한 특고압 발생부는 PWM 제어된 전압을 입력받아 특고압으로 승압시키며 고압 펄스성 전압과 매우 높은 dV/dt 전압이 인가되므로 Stray Capacitance가 최소가 되어야 하며 절연파괴로부터 보호될 수 있어야 한다. 고압 정류부는 Inverter와 특고압 변압기에 의하여 전원이 공급되므로 교류전압의 교번 순간에 매우 높은 전압변동률을 가지는 Fast Recovery High Voltage Rectifier로 설계 제작되어졌다. 펄스 스위치인 IGBT 스위치는 Gate Driver에 의해 구동되어 지며 주어진 펄스 사양을 만족시키게 된다. 특히 소자의 전압특성을 고려하여 120KV의 전압 값을 갖도록 설계, 제작하였다.

  • PDF

Copper Oxide Growing Properties by Series Arc at the Contacts of Wires in 44V AC and DC (44V AC 및 DC 전원에서 직렬아크에 의한 전선 접속부에서의 산화물 성장 특성)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Kim, Dong-Ook;Kim, Dong-Woo;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2138-2139
    • /
    • 2011
  • 본 논문에서는 44V AC 및 DC전원에서 직렬아크에 의한 전선 접속부에서의 산화물 성장 특성에 대하여 실험, 분석하였다. 실험에 사용된 전선은 동전선과 황동선으로 각각 지름 1.0mm을 사용하였으며, 교류의 경우 3가지 접속조건, 직류의 경우 4가지의 접속 조건으로 하여 전선 접촉면에서 직렬아크가 발생하였을 때 2A, 3A, 4A의 전류에서 산화물의 성장 특성과 접촉면 양단의 전압강하 변화, 산화물의 성장 길이 및 방향, 온도 분포 등에 대하여 분석하였다. 실험, 분석결과, 동전선과 동전선의 접속에서 가장 산화물의 성장이 잘 이루어짐을 볼 수 있었으며, 교류에서는 접촉면을 중심으로 좌우로, 직류에서는 접촉면을 중심으로 +극(양극) 방향으로만 산화물이 성장함을 볼 수 있었다. 본 연구 결과는 AC 및 DC 전원에서의 전기안전을 위한 기술 자료로 활용할 수 있을 것으로 기대된다.

  • PDF

MEMS-based Direct Methanol Fuel Cells and Their Stacks for the Reduction of Cell-to-Cell Deviation and Interconnection Voltage Drop (단위 셀간 성능편차 및 접속접안 강하 초소화를 위한 극소형 직접메탄올 연료전지 스택의 설계 및 제작)

  • Seo, Young-Ho;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.10
    • /
    • pp.981-985
    • /
    • 2007
  • We present a MEMS-based portable Direct Methanol Fuel Cell (micro-DFMC), featured by a platinum sputtered microcolumn electrode and a built-in fuel chamber containing a limited amount of methanol fuel. Also presented is a micro-DMFC stack structure having a common electrolyte sandwiched by the microcolumn electrodes. The single cells with ME16 and PE16 electrodes show the maximum power densities of $31.04{\pm}0.29{\mu}W/cm^2$ and $9.75{\pm}0.29{\mu}W/cm^2$, respectively; thus indicating the microcolumn electrode (ME16) generates the power density (3.2 times) higher than the planar electrode (PE16). The single cell tests of ME16 and ME4 electrodes (Fig.8) show the maximum power of $31.04{\pm}0.29{\mu}W/cm^2$, and $25.23{\pm}2.7{\mu}W/cm^2$, respectively; thus demonstrating the increased window frame reduces the normalized standard power deviation (standard deviation over the average power). The normalized deviation of 0.11 in ME4 cell has been reduced to 0.01 in ME16 cell due to the increased window frames. The maximum power density of 4-cell stack is 15.7 times higher than that of the single cell. 4-cell stack produces the power capacity of 20.3mWh/g during 980min operation at the voltage of 450mV with the load resistance of $800{\Omega}$.

Analysis of Voltage Drop and Thermal Characteristics for Poor Connections at Electrical Connector of Circuit Breaker of Small Size Pulverizer below 5.5kW (5.5kW이하의 소형분쇄기 차단기 접속부의 접촉불량에 의한 전압강하 및 열적 특성 분석)

  • Kim, Sang Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.26-31
    • /
    • 2015
  • This paper describes the characteristics of voltage drop and thermal for poor connection on electrical connector of circuit breaker in control box of small size pulverizer. In order monitor, we did the changes of RMS in voltage and temperature value with video and made normal state over $2.5N{\cdot}m$ and poor connections state below $0.2N{\cdot}m$ by screw gage. In case of voltage signal, the voltage drop was increased when the current was increased due to poor connections. In case of temperature signal, the temperature difference indicates ten times at 5A and fourteen times at 15A in the normal state. According to increase thermal energy, the insulation of electrical wiring and connector of circuit breaker can be carbonized. The results of this study will be useful to the development of preventive devices and system for electric fire by poor connection at small size pulverizer.

Design of a Multi-Protocol Gateway System Based on Low Power Wireless Communications (저전력 무선통신 기반 다중 프로토콜 게이트웨이 시스템 설계)

  • Hong, Sung-IL;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.10
    • /
    • pp.2006-2013
    • /
    • 2015
  • In this paper we propose a multi-protocol gateway system based on low power wireless communications. The proposed multi-protocol gateway system was designed to allow real-time monitoring and control of the on-site situation through wired and wireless networks by gathering information for streetlight power control and environmental monitoring. The sensing data using multi-sensors with composite processing that selectively used wired or wireless communication (e.g., CDMA, Ethernet (TCP/IP), GPS, etc.) were designed to act as intermediaries that transmitted to the main server through ZigBee. Inaddition, they were designed by separating a CPU board and baseboard to ensure low maintenance cost and ease of hardware replacement. The proposed multi-protocol gateway system's power, impact, continuous operation stability, and immunity test results obtained a normal operation success rate of over 95% and normal continuous operation results. Moreover, in the voltage drop test, instantaneous immunity test, and conductive RF electromagnetic field immunity test, it obtained an average rating result of "A".