• Title/Summary/Keyword: 점도 측정

Search Result 7,505, Processing Time 0.029 seconds

Retail Brand Value Measurements and the Relationship with the Market Performance (소매점 브랜드 가치 구성요소와 선호도, 만족도, 재구매의도 간의 관계에 관한 연구)

  • Suh, Yong-Gu;Im, Seung-Hee
    • Journal of Distribution Research
    • /
    • v.11 no.4
    • /
    • pp.71-96
    • /
    • 2006
  • A systematic brand value management starts from its measurement. Accordingly, a number of studies have proposed to measure the value of the brands. However, most of them deal with the brand value of the tangible products. Also, in many cases, such an effort did not bring long-lasting effects because either it ended up with an one-time measurement or it employed a different measurement method each time, thus hampering the comparability of the results and the accumulation of knowledge over time. So, this study has measured retail brand value index of the discount stores and the department stores of Korea every year between 2002 and 2004. And then it provides what they have found over that period. In addition this study examines the significant relationship between retail brand value components and the market performance.

  • PDF

Experimental Study on the Isobaric Thermal Expansion Coefficient Density and Zero-shear-rate Viscosity of Viscoelastic Fluid (점탄성 유체의 정압 열팽창계수, 밀도 및 전단속도 0에서의 점동에 대한 실험연구)

  • 최민구
    • The Korean Journal of Rheology
    • /
    • v.7 no.3
    • /
    • pp.181-191
    • /
    • 1995
  • 점탄성유체의 물성치들 중 정압열팽창계수 및 밀도는 자연대류 열전달 연구에 전단 속도 0에서의 점도는 점탄성유체에 대한 모델들 사용 시 필요하다. 본 연구에서는 점탄성유 체이며 마찰 감소 첨가제, 유전자 분리용액동으로 사용하는 Separan AP-273 용액의 정압열 팽창계수, 밀도 및 전단속도 0에서의 점도에대한 농도 및 온도의 영향을 조사하였다. 작동유 체의 물성치들은 10~6$0^{\circ}C$의 온도범위와 100~20,000wppm의 농도범위에서 측정되었다. 작 동유체의 물성치들에 미치는 열주기와 노화의 영향을 조사하기 위해서 정압열팽창계수와 전 단속도 0에서의 점도를 교대로 두 번씩 측정했다. 정압열팽창계수 및 밀도를 측정하는 장치 의 측정 정밀도는 증류수에 대한 측정치와 문헌에 나타난 자료를 비교하여 얻었고 이는 $\pm$ 2%이내였다. Separan AP-273용액의 정압열팽창계수 및 밀도는 증류수의 값들로 대치될수 있다. 작동유체의 정압열팽창계수와 밀도는 열주기와 노화의 영향을 받지 않았다. 낙하식 점 도계를 사용해 측정한 겉보기점도 값들을 나타내느 flow curve에서 전단속도가 0이 되는방 향으로 겉보기점도를 외삽시켜 Separan AP-273용액에 대한 전단속도0에서의 점도를 얻었 다. 정압열팽창계수 측정 전후에 측정한 작동유체에 대한 전단속도 0에서의 점도는 열주기 와 노화로 인해 퇴화되었다.

  • PDF

Measurements of Viscosity and Characteristic Times of Viscoelastic Fluids with the Falling ball Viscometer and Capillary Tube Viscometer (낙구식 점도계와 모세관 점도계를 이용한 점탄성유체의 점성과 특성시간의 측정)

  • 전찬열;황태성;유상신
    • The Korean Journal of Rheology
    • /
    • v.2 no.2
    • /
    • pp.19-27
    • /
    • 1990
  • 레이저와 타이머장치를 설치한 낙구식 점도계에서 구와 니들이 주어진 구간을 통과 하는 시간을 측정하여 종말속도를 정확히 결정하였고 점성이 작은유체와 낮은 전단률 점성 과 영전단률 점성은 속이 빈 알루미늄 구와 니들이 이용하여 측정하였다. 알루미늄 구와 니 들의 속에 철분을 삽입하여 밀도를 다양하게 변화시켰다. 낙구식 점도계에서 측정한 낮은 전단률 점성과 영 전단률 점성 그리고 모세관점도계에서 측정한 높은전단률 점성과 무한 전 단률 점성을 이용하여 점탄성 유체의 특성이완시간을 결정하였다. 실린더 속의 시험용 유체 를 교란시키지 않고 밑면에 떨어진 구를 회수하는 장치를 설치하였다. 이 장치는 하나의 구 로써 점탄성유체의 특성확산시간을 측정하는데 대단히 효과적이었다. Polyacrylamide Separan AP-273 용액(농도 500-200 wppm)의 특성이안시간과 특성화산시간을 낙구식 점도 계와 모세관 점도계의 실험결과를 이용하여 결정하고 폴리며 용액의 퇴화 현상을 실험적으 로 분석하였다.

  • PDF

A Study on the Setting of Breast Measurement Points on 3D Scan Data

  • Sohn, Boo-Hyun;Han, Hyun-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.5
    • /
    • pp.81-90
    • /
    • 2020
  • In this paper, we propose setting measurement point in the 3D scan data based on the manual measurement data. The optimal 3D body scan postures and measurement points for automatic measurement of breast were set up. The outer breast point may be different depending on the body shape or standing posture as it is on the line connected from the bisecting point of the lateral waist thickness to front armpit point. Therefore, it is necessary to consider the breast-related outer point proposed in this study. And many researches need to reduce the differences between MAM and 3D dimension items associated with the upper breast point. When measuring depth, the difference by pressing in MAM should be taken into account. And the differences in flexion depending on breast type can make a difference in the 3D measurement. So the measurement method in 3D scan should be further studied depending on the types of breast and verified by multiple subjects.

Estimation of LFT viscosity from CAE analysis with measuring cavity pressure (캐비티 내압 측정 및 CAE해석을 통한 Long Fiber Thermoplastic(LFT)의 점도 추정)

  • Kim, Yong-Hyun;Noh, Seong-Kyu;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.345-348
    • /
    • 2011
  • 본 논문에서는 LFT와 같은 고점도 수지의 점도를 추정하기 위한 방법을 제시하였다. 실제 사출공정에서의 점도를 추정함으로써 신뢰할 수 있는 점도데이터를 제공하기 위한 방법을 제시 하였다. 우선 금형 내에 캐비티 압력을 측정할 수 있는 시스템을 구성하였고, 이 시스템을 이용해서 실제 사출과정에서 나타나는 압력 변화를 측정하는 것이다. 상용화 된 CAE 프로그램(Moldflow)은 사출공정에서 캐비티 내부를 흐르는 수지의 압력변화를 모사할 수 있다. 만약, CAE D/B에 있는 수지의 점도 데이터가 정확하다고 가정하면, 실험에서 측정한 압력 프로파일과 CAE로부터 계산 된 압력 프로파일이 일치해야 한다. 이것이 실험값과 일치하지 않으면 가정한 값을 CAE D/B에 입력해서 일치할 때까지 반복함으로써 신뢰성 있는 점도를 추정 할 수 있다. 한편, LFT에 대하여 적용하여 최적화 된 점도 데이터도 추정할 수 있었다.

  • PDF

Study on Mixing Characteristic and Rheology of Polymer/Graphite Composites for a Bipolar Plate of Polymer Electrolyte Membrane Fuel Cell (고분자 전해질막 수소 연료 전지 분리판 용 고분자/흑연 복합 재료의 혼합 및 유변학적 특성에 관한 연구)

  • Yoo, Tae-Hyun;Kim, Dong-Hak;Son, Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4673-4678
    • /
    • 2011
  • In this paper, studies on a mixing characteristic and viscosity measurement of polymer/graphite composites for a bipolar plate of the polymer electrolyte membrane fuel cell were presented. Since the materials for the bipolar plate should be electrically conductive, contents of solid graphite in the composite are very high. As a consequence, a viscosity of the polymer/graphite composite used for the bipolar plate is very high and the measurement of the viscosity is difficult. Viscosity measurements of the polymer/graphite composites were not possible because pressure drops were continuously fluctuated during the viscosity measurements when a conventional capillary die was used. After the die design was optimized, the steady state pressure drop could be achieved, but the viscosity thus measured was not reproducible. After many trials with different experimental techniques, it was found that melt blending of the grinded powder mixtures of both PET and graphite provides reproducible viscosity measurements and electric conductivities of the polymer/graphite composites.

Automatic Object Recognition in 3D Measuring Data (3차원 측정점으로부터의 객체 자동인식)

  • Ahn, Sung-Joon
    • The KIPS Transactions:PartB
    • /
    • v.16B no.1
    • /
    • pp.47-54
    • /
    • 2009
  • Automatic object recognition in 3D measuring data is of great interest in many application fields e.g. computer vision, reverse engineering and digital factory. In this paper we present a software tool for a fully automatic object detection and parameter estimation in unordered and noisy point clouds with a large number of data points. The software consists of three interactive modules each for model selection, point segmentation and model fitting, in which the orthogonal distance fitting (ODF) plays an important role. The ODF algorithms estimate model parameters by minimizing the square sum of the shortest distances between model feature and measurement points. The local quadric surface fitted through ODF to a randomly touched small initial patch of the point cloud provides the necessary initial information for the overall procedures of model selection, point segmentation and model fitting. The performance of the presented software tool will be demonstrated by applying to point clouds.

A Study on the Dynamic Range Expansion of the Shack-Hartmann Wavefront Sensor using Image Processing (영상처리 기법을 이용한 샥-하트만 파면 센서의 측정범위 확장에 대한 연구)

  • Kim, Min-Seok;Kim, Ji-Yeon;Uhm, Tae-Kyung;Youn, Sung-Kie;Lee, Jun-Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.375-382
    • /
    • 2007
  • The Shack-Hartmann wavefront sensor is composed of a lenslet array generating the spot images from which local slope is calculated and overall wavefront is measured. Generally the principle of wavefront reconstruction is that the spot centroid of each lenslet array is calculated from pixel intensity values in its subaperture, and then overall wavefront is reconstructed by the local slope of the wavefront obtained by deviations from reference positions. Hence the spot image of each lenslet array has to remain in its subaperture for exact measurement of the wavefront. However the spot of each lenslet array deviates from its subaperture area when a wavefront with large local slopes enters the Shack-Hartmann sensor. In this research, we propose a spot image searching method that finds the area of each measured spot image flexibly and determines the centroid of each spot in its area Also the algorithms that match these centroids to their reference points unequivocally, even if some of them are situated off the allocated subaperture, are proposed. Finally we verify the proposed algorithm with the test of a defocus measurement through experimental setup for the Shack-Hartmann wavefront sensor. It has been shown that the proposed algorithm can expand the dynamic range without additional devices.

사출성형 공정 캐비티 내 압력 측정과 CAE 해석을 활용한 점도 함수 추정

  • Jeon, Kang-Il;Lim, Seung-Hyun;Noh, Seung-Kyu;Kim, Dong-Hak
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.305-308
    • /
    • 2010
  • 본 연구에서는 사출 성형에서 Cavity내의 압력을 측정하여 사출 성형기에서의 설정한 변수 즉, 사출 압력에 따라 Cavity내의 압력이 사출 공정동안 어떠한 추이를 나타내는지 관찰하였다. 이를 CAE 해석과 비교 분석하여 결과에 따른 점도 함수와의 관계를 알아보았다. 우선 Cavity의 압력을 측정하기 위하여 Cavity 내에 압력센서를 설치하고, 이를 시간에 따른 압력측정 결과를 보기 위하여 압력센서 시스템을 제작 하였다. 실제 사출성형하면서 Cavity 내 압력을 측정하고 CAE 해석 결과의 압력 변화와 비교한다. 이때 일반적으로 CAE 해석과 실험결과가 일치하지 않으므로 새로운 점도 곡선을 추정하여 CAE 소프트웨어 D/B(Data Base) 파일에 입력하여 다시 해석하고 실험 결과와 비교하여 압력변화가 일치할 때까지 반복해서 수행한다. 이때 점도는 Power Law로 가정하여 D/B 파일에서 K와 n값을 조절할 수 있고 일반적으로 n값은 Base Resin과 동일하므로 K값의 변화만을 고려하여 압력변화를 해석한다.

  • PDF

소형 왕복동식 압축기 셸에 가해지는 가진력의 간접적 측정

  • 김성진;강경식;심재술
    • Journal of KSNVE
    • /
    • v.7 no.6
    • /
    • pp.899-908
    • /
    • 1997
  • 본 글에서는 소형 압축기 셸과 같은 비교적 복잡한 기계 구조물의 간접적 입력 측정에 대한 결과 및 직접 측정과의 비교를 기술하였고 다수 응답의 동시 측정에 따른 문제점을 해결코자 기준점을 이용한 전달함수의 측정 방법을 제시 하였다. 하부 빈 셸에 대한 실험 결과, 압축기의 셸과 같은 비교적 복잡한 구조물에 대해서도 간접 입력 측정을 상당한 신뢰성을 갖고 시도할 수 있으며 특히 공진점이나 영점 부근에서의 추정 오차는 측정점의 갯수를 증대시킴으로써 크게 개선 시킬수 있음을 보여주었다.

  • PDF