• Title/Summary/Keyword: 절연평가

Search Result 487, Processing Time 0.039 seconds

Numerical analysis of thermally stimulated current due to lonic space charge polarization by hopping method (호핑법에 의한 이온 공간전하 분극 열자극전류의 수치해석)

  • 김의균;국상훈
    • Electrical & Electronic Materials
    • /
    • v.4 no.1
    • /
    • pp.53-64
    • /
    • 1991
  • 절연체중에 있는 하전입자의 거동은 절연재료의 특성에 많은 영향을 준다. 본 연구에서는 호핑모델에 의한 수치해석법을 TSC특성과 쌍극자분극에 대한 TSC특성은 차이가 있었다. 실험과 대응시켜 가동이온에 관한 물성정수의 평가를 하였다. 호핑모델에 의해서 불포화 TSC와 I-V특성의 수치계산을 하였다.

  • PDF

Power Cable Insulation Diagnosis Using Low Frequency Power (저주파수 전원을 이용한 전력케이블 절연평가에 관한 연구)

  • Kim, Sung-Min;Lee, Sang-Hun;Jang, Jae-Yel
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1603-1603
    • /
    • 2011
  • As time goes by these cables make a insulation problems, and ask for a preventive diagnosis method. Cable has very high electrostatic capacity and insulation defects mainly caused by water-tree(WT). Dissipation factor test is very useful for detecting WT but it needs huge power supply. In this paper we presented a cable insulation diagnosis by dissipation factor using low frequency power supply.

  • PDF

A effect on the high field conduction and carrier traps in polythylene (폴리에틸렌의 고전계 전기전도 및 캐리어 트랩에 미치는 공중합의 효과)

  • 유근민;이종호;이규철
    • Electrical & Electronic Materials
    • /
    • v.6 no.1
    • /
    • pp.50-54
    • /
    • 1993
  • 각종 monomer를 공중합시킨 PE의 고전계 전기전도와 X선 유기 TSC(X-ray induced thermally stimulated current)를 측정하고 공중합 monomer의 영향에 대하여 검토하였다. 할로겐을 함유한 공중합 PE에서 고전계 전기전도가 억제되는 것을 관찰하였다. 또 할로겐을 함유하는 monomer를 공중합시킨 PE의 X선 유기 TSC에서는 공중합에 의한 전자 trap은 약 0.4eV정도로 평가된다. 이들 시료에서 절연 파괴 강도가 상승한 것은 전자 트랩이 전자의 전계가속을 억제하여 고전계 전기전도를 억제시키고 절연파괴강도를 향상 시킨 것으로 추측된다.

  • PDF

Evaluation of Insulating Reliability in Epoxy Composites using Dielectric Breakdown Data (절연 파괴 데이터를 이용한 에폭시 복합체의 절연 신뢰도 평가)

  • Park, Geon-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.114-118
    • /
    • 2005
  • In this study, the DC dielectric breakdown of epoxy composites used for molding material was experimented and then its data were simulated by Weibull distribution equation. From the analysis of Weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1[%], the applied field value needed to be under 21.5[kV/mm].

  • PDF

Evaluation of Effects of Impurities on Insulating Properties of Polymeric Insulator in Power Distribution Cable (배전케이블내 고분자 절연체의 절연성능에 미치는 불순물의 영향평가)

  • Cho, Young-Shin;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1402-1404
    • /
    • 1997
  • To evaluate the effects of impurities on insulating properties of polymeric insulator in high electric power distribution cable, OIT and OMT were measured. By using Eyring plot, the thermodynamic parameters of ${\Delta}H$ and ${\Delta}S$ could be obtained.

  • PDF

Lifetime Evaluation of Insulating Spacer used in Gas Insulated Switchgear (가스절연개폐장치용 절연스페이서의 수명평가)

  • Kim, M.K.;Lee, J.G.;Kim, I.S.;Jeong, J.Y.;Oh, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.190-191
    • /
    • 2006
  • In this paper, a method to assess the reliability of an insulating spacer used in gas insulated switchgear by electrical accelerated lifetime test is represented. And a test plan to assure the expected lifetime with 90 % confidence level is also included.

  • PDF

A Review of Cable Condition Monitoring for Nuclear plants (원자력 발전소 케이블 상태 감시방법의 국내외 동향)

  • Hang, Yun-Sik;Kim, Chul-Hwan;Goo, Chul-Soo;Kim, Bok-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.555-557
    • /
    • 2000
  • 원자력 발전소에서 사용되어지는 케이블은 전원 및 제어신호를 안정하게 전달하는 역할을 하며, 비상상태 발생시에는 원자로를 안전하게 shut-down시키는 통로 역할을 하므로 매우 중요하다. 케이블 상태 감시시 절연 및 피복재료는 종류 및 배합내용이 다양하기 때문에 종래의 자료로부터 전선과 케이블의 열화 또는 수명을 추정하기가 극히 어려우며 방사선에 노출이 되는 케이블의 경우 노화현상의 진행이 빠르고 방사선 열화로 수명이 단축되므로 국내 실정을 감안한 독자적인 검증방법 도출, 규제기술 기반 구축 필요 및 규제의 합리화와 효율화 필요성이 대두되고 있다. 기존에 사용해온 케이블 진단 방법에는 절연 파괴 강도 측정을 통한 노화진단, 산화 방지능력 측정을 통한 노화진단, 자켓 및 절연체의 판단, 연신율에 의한 노화진단, 케이블 Indenter에 의한 노화진단, 온도 및 방사선 등의 특정상태에 대한 평가, 유사한 환경조건에 대한 주기적 검토 등이 있다. 기존의 국내외 케이블 상태 감시방법을 조사 연구하므로서 케이블 열화에 대비한 수명관리 규제 기술 및 상태감시 (Condition Monitoring : CM) 기술의 평가 기준을 결정 하고자 한다.

  • PDF