• Title/Summary/Keyword: 절대 측정

Search Result 748, Processing Time 0.03 seconds

Method for Measuring Absolute Position of a Yard Crane for Port Automation (항만 자동화를 위한 야드 크레인의 절대위치 측정 기법)

  • 전태원;유우종;이홍희;김흥근;노의철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.163-170
    • /
    • 2004
  • Since 1960s, a container shipping volume has increased dramatically and continuous on a trend of rapid growth, and so the number of containers handled at the port increases. The position measurement of the yard crane is very important for improving the operating efficiency of the port. This paper describes the method to measure the absolute position of yard crane accurately and rapidly, using both the output pulse of an encoder and infrared sensors. The crane position is calculated by counting the output pulse of an incremental encoder, which is mounted on the wheel in the crane. By the way, the wheel slippage on rail may cause some errors in the crane position information obtained from encoder pulse, and the infrared sensor is used to compensate for errors in the crane position information. The performance of proposed method is verified on experimental results with the simulator of yard crane, the size of which is about 1/10 with the real crane.

Principle and Application of 'Image-mapping' in-situ U-Pb Carbonate Age-dating ('Image-mapping' in-situ U-Pb 탄산염광물 연대측정법의 원리 및 적용)

  • Ha Kim;Seongsik Hong;Chaewon Park;Jihye Oh;Jonguk Kim;Yungoo Song
    • Economic and Environmental Geology
    • /
    • v.56 no.2
    • /
    • pp.115-123
    • /
    • 2023
  • We introduce a new 'image-mapping' in-situ U-Pb dating method using LA-ICP-MS, proposed by Drost et al. (2018), and show the characteristics and usability of this method through several examples of absolute age results determined by first applying it to samples from the Joseon Supergroup of the Early Paleozoic Era in Korea. Unlike the previous in-situ spot analysis, this in-situ U-Pb dating method for carbonate minerals can determine the absolute age with high reliability by applying the 'image-mapping' method of micro-sized domains based on micro-textural observation, as well as determine the absolute age of multiple geological 'events' that occurred after deposition. This was confirmed in the case of determining the syn-depositional age and the multiple post-depositional ages from carbonate minerals of the Makgol and the Daegi Formations. Therefore, if the 'image-mapping' in-situ U-Pb dating method is applied to determine the absolute age of various types of carbonate minerals that exist in various geological environments throughout the geologic era, it will be possible to secure new geological age information.

Comparative Evaluation of Cardiac Output using Echocardiography in Beagle Dogs (비글견에서 심초음파를 이용한 심박출량 측정에 관한 비교 연구)

  • Park, Kitae;Yeon, Seongchan;Lee, Heechun
    • Journal of Veterinary Clinics
    • /
    • v.29 no.5
    • /
    • pp.384-390
    • /
    • 2012
  • Echocardiographic measurements of cardiac output, including the modified Simpson's method, Automated Contour Tracking(ACT) method, and left ventricular outflow method are well described methods of evaluating cardiac function due to its reliability and the benefits of its non-invasive technique in human medicine. The purpose of this study was to evaluate the accuracy of an echocardiography estimate of cardiac output in isoflurane-anesthetized beagle dogs and was to compare the ACT method to the other methods used in measurement of cardiac output. In healthy beagle dogs, cardiac output results by echocardiography estimate methods showed an excellent correlations with those by the thermodilution method (The modified Simpson's method : r = 0.815, $r^2=0.665$, y = 0.434x + 0.311 ; ACT method : r = 0.86, $r^2=0.748$, y = 0.391x + 0.242 ; ventricular outflow method : r = 0.691, $r^2=0.478$, y = 0.593x + 0.242). Among the results obtained, the ACT method showed the highest correlation coefficient. In conclusion, our study demonstrated that echocardiography estimate methods did not prove to be suitable in accurately measuring absolute cardiac output values but showed an excellent correlation with thermodilution method. Therefore, by using the measurement of cardiac output as supplemental data, echocardiography estimate methods can be used for detection and correction of hemodynamic disturbances during emergency and anesthesia in veterinary practice.

Estimate of walking state of the knee disarticulation prosthesis using position control algorithm of absolute encoder (절대위치 엔코더의 위치제어 알고리즘을 이용한 의지 장치의 보행 상태 추론)

  • Song, H.J.;Park, J.Y.;Shim, J.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2013
  • In this paper, we proposed how to estimate the walking state in the knee disarticulation prosthesis's knee angle control. In control of the knee disarticulation prosthesis, we can estimate walking state that measurement of knee angle using absolute encoder and measurement of load on the soles using strain gage. We suggested a method of estimating the current walking states which can be divided into four cases and showed the effectiveness of the method via a series of experiments.

  • PDF

Absolute Distance Measurement using Synthetic Wavelength of Femto-second Laser (펨토초 레이저의 합성파를 이용한 절대거리 측정)

  • Kim Yun-Seok;Jin Jong-Han;Joo Ki-Nam;Kim Seung-Woo
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.569-572
    • /
    • 2005
  • Technological feasibility of using recently-available femtosecond ultra short pulse lasers for advanced precision length metrology is investigated with emphasis on absolute distance measurements with $10{\mu}m$ ??resolution over extensive ranges. The idea of using femtosecond lasers for the measurement of absolute distances is based on the fact that a short pulse train is a mode-locked combination of discrete monochromatic light components spanning a wide spectral bandwidth. The synthetic wavelength is created from the repetition frequency, $f_r$ of the femtosecond laser and for more precise resolution, higher-order harmonics of the repetition frequency may be selected as the synthetic wavelength by using appropriate electronic filters.

  • PDF

해석적 사진측정에 있어서 경중률을 고려한 표정해석에 관한 연구

  • 안철호;유복모;염재홍
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.1 no.2
    • /
    • pp.16-22
    • /
    • 1983
  • The method of least squares is an adequate method of adjustment in various fields of engineering where redundant observations are necessary to obtain accurate values. The Consideration of weight of each Observation can improve the accuracy if the reliabilities of observations vary. The strip coordinates were weighted as inversely proportionate to the rotations $\kappa, \varphi, \omega$ which occur in the computation of model coordinates. The resulting errors in absolute coordinates were compared with the errors unweighted case to investigate the influence of orientation elements on absolute coordinates.

  • PDF

Development of Designing and Performing Procedure for Well Test in Coalbed Methane(CBM) Reservoir (석탄층 메탄가스 저류층의 유정생산시험 설계 및 수행절차 수립연구)

  • Park, Jinyoung;Lee, Jeonghwan
    • Economic and Environmental Geology
    • /
    • v.46 no.4
    • /
    • pp.279-289
    • /
    • 2013
  • The most critical factor in developing coalbed methane(CBM) reservoir is absolute permeability. Both productivity and economics of the CBM depend on the absolute permeability. The methods to estimate it are core analysis and well test. However, absolute permeability determined by core analysis cannot be a good representative of CBM reservoir. Therefore, it is generally estimated by well test. In this study, well test methods applicable of CBM reservoir were classified with their characteristics. Merits and demerits of each well tests were also analyzed. Based on those parameters, design considerations and procedures of well test were derived. After each well tests was performed, the procedure of well test interpretations to estimate reservoir properties such as absolute permeability and skin factor was presented.

Development of 3D absolute displacement monitoring system and its application at the stage of tunnel construction (터널 시공 중 3차원 절대변위 계측시스템의 개발과 적용)

  • Bang, Joon-Ho;Kim, Ki-Young;Jong, Yong-Hun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.3
    • /
    • pp.229-240
    • /
    • 2007
  • The 3D absolute displacement monitoring system has been developed to analyze the tunnel convergence measured under construction of underground structures and to manage effectively the measured data. The system is comprised of the total station, the anchor-typed target pin and the 3D absolute displacement measurement and management program. In this paper, the types and specifications of the 3D total station were presented. The anchor-typed target pin, an improved model of traditional one, was developed and its sightable distance and measurement accuracy were checked by field tests. Also a 3D absolute displacement measurement and management program, TEMS 3D, was developed to provide some analysis tools including the trend and influence lines. L/C ratio, S/C ratio and the like. The developed system was applied the construction stage of a railway tunnel for testing purpose. It is verified that the developed system is capable of predicting weak zones ahead of tunnel face by comparing with results of TSP (Tunnel Seismic Prediction) survey.

  • PDF