• Title/Summary/Keyword: 전지구

Search Result 469, Processing Time 0.026 seconds

Global Temperature Trends of Lower Stratosphere Derived from the Microwave Satellite Observations and GCM Reanalyses (마이크로파 위성관측과 모델 재분석에서 조사된 전지구에 대한 하부 성층권 온도의 추세)

  • Yoo, Jung-Moon;Yoon, Sun-Kyung;Kim, Kyu-Myong
    • Journal of the Korean earth science society
    • /
    • v.22 no.5
    • /
    • pp.388-404
    • /
    • 2001
  • In order to examine the relative accuracy of satellite observations and model reanalyses about lower stratospheric temperature trends, two satellite-observed Microwave Sounding Unit (MSU) channel 4 (Ch 4) brightness temperature data and two GCM (ECMWF and GEOS) reanalyses during 1981${\sim}$1993 have been intercompared with the regression analysis of time series. The satellite data for the period of 1980${\sim}$1999 are MSU4 at nadir direction and SC4 at multiple scans, respectively, derived in this study and Spencer and Christy (1993). The MSU4 temperature over the globe during the above period shows the cooling trend of -0.35 K/decade, and the cooling over the global ocean is 1.2 times as much as that over the land. Lower stratospheric temperatures during the common period (1981${\sim}$1993) globally show the cooling in MSU4 (-0.14 K/decade), SC4 (-0.42 K/decade) and GEOS (-0.15 K/decade) which have strong annual cycles. However, ECMWF shows a little warming and weak annual cycle. The 95% confidence intervals of the lower stratospheric temperature trends are greater than those of midtropospheric (channel 2) trends, indicating less confidence in Ch 4. The lapse rate in the trend between the above two atmospheric layers is largest over the northern hemispheric land. MSU4 has low correlation with ECMWF over the globe, and high value with GEOS near the Korean peninsula. Lower correlations (r < 0.6) between MSU4 and SC4 (or ECMWF) occur over $30^{\circ}$N latitude belt, where subtropical jet stream passes. Temporal correlation among them over the globe is generally high (r > 0.6). Four kinds of lower stratospheric temperature data near the Korean peninsula commonly show cooling trends, of which the SC4 values (-0.82 K/decade) is the largest.

  • PDF

Studies on a Feasibility of Swine Farm Wastewater Treatment using Microbial Fuel Cell (미생물연료전지의 가축분뇨 처리 가능성 연구)

  • Jang, Jae-Kyung;Kim, Se-Hee;Ryou, Young-Sun;Lee, Sung-Hyoun;Kim, Jong-Gu;Kang, Young-Goo;Kim, Young-Hwa;Choi, Jung-Eun
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.4
    • /
    • pp.461-466
    • /
    • 2010
  • In this study the feasibility of simultaneous electricity generation and treatment of swine farm wastewater using microbial fuel cells (MFCs) was examined. Two single-chamber MFCs containing an anode filled with different ratio of graphite felt and stainless-steel cross strip was used in all tests. The proportion of stainless-steel cross strip to graphite felt in the anode of control microbial fuel cell (CMFC) was higher than that of swine microbial fuel cell (SMFC) to reduce construction costs. SMFCs produced a stable current of 18 mA by swine wastewater with chemical oxygen demand (COD) of $3.167{\pm}80\;mg/L$ after enriched. The maximum power density and current density of SMFCs were $680\;mW/m^3$ and $3,770\;mA/m^3$, respectively. In the CMFC, power density and current density was lower than that of SMFC. CODs decreased by the SMFC and CMFC from $3.167{\pm}80$ to $865{\pm}21$ and $930{\pm}14\;mg/L$, achieving 72.7% and 70.6% COD removal, respectively. The suspended solid (SS) of both fuel cells was also reduced over 99% ($4,533{\pm}67$ to $24.0{\pm}6.0\;mg/L$). The concentration of nutritive salts, ${NH_4}^+$, ${NO_3}^-$, and ${PO_4}^{3-}$, dropped by 65.4%, 57.5%, and 73.7% by the SMFC, respectively. These results were similar with those of CMFC. These results show that the microbial fuel cells using electrode with mix stainless-steel cross strip and graphite felt can treat the swine wastewater simultaneously with an electricity generation from swine wastewater.

Active Fire Detection Using Landsat 8 OLI Images: A Case of 2019 Australia Fires (Landsat 8 OLI 영상을 이용한 산불탐지: 2019년 호주 산불을 사례로)

  • Kim, Nari;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.775-784
    • /
    • 2020
  • Recent global warming and anthropogenic activities have caused more frequent and massive wildfires with longer durations and more significant damages. MODIS has been monitoring global wildfires for almost 20 years, and GK2A and Himawari-8 are observing the wildfires in East Asia 144 times a day. However, the spatial resolution of 1 to 2 km is not sufficient for the detection of small and medium-size active fires, and therefore the studies on the active fire detection using high-resolution images are essential. However, there is no official product for the high-resolution active fire detection. Hence, we implemented the active fire detection algorithm of Landsat 8 and carried out a high-resolution-based detection of active fires in Australia in 2019, followed by the comparisons with the products of Himawari-8 and MODIS. Regarding the intense fires, the three satellites showed similar results, whereas the weak igniting and extinguishing fires or the fires in narrow areas were detected by only Landsat 8 with a 30m resolution. Small-sized fires, which are the majority in Korea, can be detected by the high-resolution satellites such as Landsat 8, Sentinel-2, Kompsat-3A, and the forthcoming Kompsat-7. Also, a comprehensive analysis together with the geostationary satellites in East Asia such as GK2A, Himawari-8, and Fengyun-3 will help the interoperability and the improvement of spatial and temporal resolutions.

The Efficiency and General Equilibrium Effect by the Emission Trading Structure under the Climate Change Convention (기후변화협약 하의 배출권 거래 대상에 따른 일반균형효과와 효율성 비교)

  • Hur, Gahyeong;Cho, GyeongLyeob
    • Environmental and Resource Economics Review
    • /
    • v.15 no.2
    • /
    • pp.201-245
    • /
    • 2006
  • We applied general equilibrium model to analysis the economic impact of international emission trading by sector and the efficiency of the Convention to study whether Climate Change Convention satisfy the efficiency. We divided the world as 4 groups : USA, OECD members w/o USA (OEC), Former Soviet Union (FSU) and Developing countries (DEV). Compared to no trading, global trading would accomplish the same environmental effect with less cost as much as 97.8 billion$, which is the surplus of trading. However, half of it is taken by USA and 20% by OEC. FSU and DEV have only 18% and 10%. This result suggest the two things. First, the emission trading is effective as far as the participation of developing countries are guaranteed. If they do not take part in the coalition and emit the leakage, it may threaten the stability of the international trading coalition. Second, we found the logical ground of the side payment for developing countries. The permit buying countries take more share of the surplus under the emission trading, while the energy sector of developing countries shrinks to sell permits, which may adversely affect to economic growth of the countries. Therefore, the Annex-I countries need to provide side payment to lead the participation of the developing countries.

  • PDF

Gravity-Geologic Prediction of Bathymetry in the Drake Passage, Antarctica (Gravity-Geologic Method를 이용한 남극 드레이크 해협의 해저지형 연구)

  • 김정우;도성재;윤순옥;남상헌;진영근
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.273-284
    • /
    • 2002
  • The Gravity-Geologic Method (GGM) was implemented for bathymetric determinations in the Drake Passage, Antarctica, using global marine Free-air Gravity Anomalies (FAGA) data sets by Sandwell and Smith (1997) and local echo sounding measurements. Of the 6548 bathymetric sounding measurements, two thirds of these points were used as control depths, while the remaining values were used as checkpoints. A density contrast of 9.0 gm/㎤ was selected based on the checkpoints predictions with changes in the density contrast assumed between the seawater and ocean bottom topographic mass. Control depths from the echo soundings were used to determine regional gravity components that were removed from FAGA to estimate the gravity effects of the bathymetry. These gravity effects were converted to bathymetry by inversion. In particular, a selective merging technique was developed to effectively combine the echo sounding depths with the GGM bathymetiy to enhance high frequency components along the shipborne sounding tracklines. For the rugged bathymetry of the research area, the GGM bathymetry shows correlation coefficients (CC) of 0.91, 0.92, and 0.85 with local shipborne sounding by KORDI, GEODAS, and a global ETOPO5 model, respectively. The enhanced GGM by selective merging shows imploved CCs of 0.948 and 0.954 with GEODAS and Smith & Sandwell (1997)'s predictions with RMS differences of 449.8 and 441.3 meters. The global marine FAGA data sets and other bathymetric models ensure that the GGM can be used in conjunction with shipborne bathymetry from echo sounding to extend the coverage into the unmapped regions, which should generate better results than simply gridding the sparse data or relying upon lower resolution global data sets such as ETOPO5.

Improvement of Anodic Performance by Using CTP Binder Containg Nickel (니켈을 함유한 콜타르 피치 결합제를 이용한 미생물연료전지 산화전극 성능개선)

  • Yoon, Hyung-Sun;Song, Young-Chae;Choi, Tae-Seon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.499-504
    • /
    • 2015
  • The composite anodes of expanded graphite (EG) and multiwall carbon nanotube (MWCNT) for microbial fuel cells were fabricated by using coal tar pitch (CTP) binder containing nickel (Ni), and the effect of the anodes with the binders on the performance of the MFCs were examined in a batch reactor. During the start-up of the MFCs, quick increase in voltage was observed after a short lag phase time, indicating that the CTP binder is biocompatible. The biomass attatched on the anode surface was more at higher Ni content in the binder, as well as at smaller amount of CTP binder for the fabrication of the anode. The internal resistance of the MFC was smaller for the anode with more biomass. Based on the results, the ideal combination of CTP and Ni for the CTP binder for anode was 2 g and 0.2 g, respectively. The maximum power density was $731.8mW/m^2$, which was higher 23.7% than the anode with Nafion binder as control. The CTP binder containing Ni for the fabrication of anode is a good alternative in terms of performance and economics of MFCs.

Current Generation from Microbial Fuel Cell Using Stainless Steel Wire as Anode Electrode (스텐철사를 전극으로 이용하는 미생물연료전지의 전류 발생)

  • Jang, Jae Kyung;Kim, Kyung Min;Byun, SungAh;Ryou, Young Sun;Chang, In Seop;Kang, Young Koo;Kim, Young Hwa
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.11
    • /
    • pp.753-757
    • /
    • 2014
  • Anode electrode in a microbial fuel cell (MFC) should transfer the receiving electron as well as provide large surface area that can be immobilized microorganisms. Microorganisms' population is one of important factors to improve the current generation and to treat the livestock wastewater by biological treatment. These studies were attempted to investigate if stainless-steel wire skein (SSWS) could be used as anode electrode replacement a graphite felt electrode in microbial fuel cell. For these studies, pretreated livestock wastewater was used diluted to 500 mg/L as COD before use. At this time, the current showed a little difference of about 5% when using each of a SSW and graphite felt (control). There was no significant difference in the current value. The organic removal rate in the microbial fuel cells used graphite felt and SSWS was 82.4% and 88.3%, respectively. The COD removal in the MFC used the SSWS was higher than that of graphite felt. Ammonium nitrogen was showed similar trend in two case all. These results about current generation and organic matter reduction seem possible that SSWS was used to anode electrode. When SSWS is used, the initial investment for system construction is expected to be able to reduce by approximately 1/50.

Carbon Storage and Absorption of Trees in the Ecological Restoration Area and Vegetation Conservation Area of Bulamsan Urban Nature Park (불암산 도시자연공원 생태복원지와 식생보전지 수목의 탄소저장량 및 흡수량)

  • Yang, Keum Chul;Kim, Jeong Seob
    • Ecology and Resilient Infrastructure
    • /
    • v.7 no.4
    • /
    • pp.284-293
    • /
    • 2020
  • We present a quantitative survey of the carbon storage and absorption capacity of tree species in the vegetation conservation and ecological restoration areas of Bulamsan urban nature park in Nowon-gu, Seoul. The density of the sawtooth oak (Quercus acutissima) community in the ecological conservation area is approximately 30 individuals/225 ㎡, while a further 20 species, such as Japanese snowbell (Styrax obassia), galcham oak (Quercus aliena), Asian Sweetleaf (Symplocos chinensis f. pilosa), East Asian ash (Fraxinus rhynchophylla), and Korean rhododendron (Rhododendron mucronulatum) are sparsely distributed. In contrast, the ecological restoration sites typically comprised Mongolian oak (Quercus mongolica), jolcham oak (Quercus serrata), and East Asian ash (Fraxinus rhynchophylla) plantations, with planting densities of 8.3, 7.7, and 14.3 individuals/25 ㎡ , respectively. Approximately 10 species, including Amur maple (Acer tataricum subsp. ginnala), Korean mountain ash (Sorbus alnifolia), Japanese spice bush (Lindera obtusiloba), and Korean rhododendron (Rhododendron mucronulatum) were identified in the ecologically restored area. The total amounts of carbon stored by the trees in the vegetation conservation and ecological restoration sites are 250.77 and 19.3 t C ha-1, respectively, and the total annual carbon uptakes are 10.28 and 2.33 t C ha-1 yr-1, respectively. The survey results are expected to provide important basic data for monitoring the carbon absorption capacity and carbon balance of green areas in the city.

Feasibility test of treating slaughterhouse by-products using microbial electrolysis cells (미생물전기분해전지를 이용한 도축부산물 처리 가능성 평가)

  • Song, Geunuk;Baek, Yunjeong;Seo, Hwijin;Kim, Daewook;Shin, Seunggu;Ahn, Yongtae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.29 no.2
    • /
    • pp.31-38
    • /
    • 2021
  • The aim of this study is to evaluate the possibility of treating slaughterhouse by-products using microbial electrolysis cells (MECs). The diluted pig liver was fed to MEC reactors with the influent COD concentrations of 772, 1,222, and 1,431 mg/L, and the applied voltage were 0.3, 0.6, and 0.9 V. The highest methane production of 5.9 mL was obtained at the influent COD concentration of 1,431 mg/L and applied voltage of 0.9 V. In all tested conditions, COD removal rate was increased as the influent COD concentration increased with average removal rate of 62.3~81.1%. The maximum methane yield of 129~229 mL/g COD was obtained, which is approximately 80% of theoretical maximum value. It might be due to the bioelectrochemical reaction greatly increased the biodegradability of pig liver. Future research is required to improve the methane yield and digestibility through optimizing the reactor design and operating conditions.

Improvement of charging efficiency of AGM lead acid battery through formation pattern research (Formation pattern 연구를 통한 AGM 연축전지의 충전 효율 향상)

  • Kim, Sung Joon;Son, Jeong Hun;Kim, Bong-Gu;Jung, Yeon Gil
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.1
    • /
    • pp.55-62
    • /
    • 2021
  • In order to improve fuel economy and reduce CO2, HEV adopts ISG system as a standard. This ISG system increased the electric load that the battery had to bear, and the number of starting increased rapidly. AGM Lead Acid batteries have been developed and used, but the charging time is about three times longer as the electrolyte amount control during formation must be maintained at a higher level compared to conventional lead-acid batteries. In this study, we tried to shorten the charging time by increasing the charging efficiency through the optimization of the formation pattern. In order to optimize the Formation Pattern, 10 charging steps and 6 discharging steps were applied to 16 multi steps, and the charging current for each step was controlled, and the test was conducted under 4 conditions (21 hr, 24 hr, 27 hr, 30 hr). As a result of simultaneous application of multi-step and discharge step, it was verified that minimizing the current loss and eliminating the sudden polarization during charging contributes to the improvement of charging efficiency. As a result, it showed excellent results in reducing the charging time by about 30 % with improved charging efficiency compared to the previous one.