• Title/Summary/Keyword: 전자 산란

Search Result 543, Processing Time 0.03 seconds

A Study on the Ultrasonic Inspection Method in High Attenuation Welds using Minimization-Polarity Threshold Algorithm (최소극 문턱치 알고리즘을 이용한 고감쇠 용접부에서 초음파 검사방법에 관한 연구)

  • Koo, Kil-Mo;Park, Chi-Seung;Choi, Jong-Ho;Ko, Duck-Young
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.3
    • /
    • pp.30-36
    • /
    • 2000
  • In this paper, an ultrasonic testing method for inspection of high attenuation welding area using the minimum Polarity threshold algorithm which combines the minimum amplitude selection algorithm and polarity threshold algorithm is suggested to increase the signal to noise ratio of the flow signal. In order to confirm the usefulness of the suggested algorithm, experiments were performed using four probes and standard specimens following the ASME Xl Code. As a result, scattering signals were observed from the SE(safe end) and CCSS (centrifugal casting stainless steel) materials due to the microstructural characteristical, and the detectability was reduced due to the highly attenuated signal from the weldment area, but it was conformed that using the suggested algorithm, the signal to noise ratio increased about 2.6.

  • PDF

Laser Speckle Imaging Using Adaptive Windowing Method (적응 윈도우 기법을 사용한 레이저 스펙클 영상의 처리)

  • Jin, Ho-Young;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.97-102
    • /
    • 2010
  • A laser speckle is a random pattern that has a granular appearance produced by reflected light when a coherent laser illuminates an irregular course surface. Most important property of laser speckle is detecting micro-vascular. Speckle image needs image processing to detect micro-vascular. This paper proposes a new image processing method for laser speckle, adaptive window method that adaptively processes laser speckle images in the spatial. Conventional fixed window based LASCA has shortcoming in that it uses the same window size regardless of target areas. Inherently laser speckle contains undesired noise. Thus a large window is helpful for removing the noise but it results in low resolution of image. Otherwise a small window may detect micro vascular but it has limits in noise removal. To overcome this trade-off, we newly introduce the concept of adaptive window method to conventional laser speckle image analysis. We have compared conventional LASCA and its variants with the proposed method in terms of image quality and processing complexity.

The Electromagnetic Properties in Uncoupled funnel-junction with Various Cr Seed Layer (비결합형 터널접합구조에서 Cr 하지층에 따른 전자기적 특성변화)

  • Park, J.W.;Jeon, D.M.;Yoon, S.Y.;Lee, J.Y.;Suh, S.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.3
    • /
    • pp.91-96
    • /
    • 2003
  • Cross-geometrical Cr/Co/Al-Ox/Co/Ni-Fe tunnel junctions were fabricated by magnetron sputtering. To form an insulating layer, The Al layer was oxidized in an atmosphere of oxygen-argon mixture at low power after deposition. To enhance the coercivity of the bottom Co layer, The Cr seed layer was deposited on the glass and it led to increase in coercivity. The coercivity increase is due to the increase of roughness through the Cr thickness. In over oxidation time, the oxidation of Co bottom layer and flat interface of insulator can increase the bottom Co coercivity. But TMR ratio gradually decrease. TMR ratio is relevant with Cr thickness, insulator thickness, and oxidation time. The maximum TMR ratio was 14% at room temperature and the TMR ratio was decreased to half at 0.51 V.

Successive Iteration of Geometrical-Optics for Diffracted Fields (기하광학 반복적용에 의한 회절파 계산)

  • Hwang, Churl-Kew;Kim, Se-Yun;Ra, Jung-Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.2
    • /
    • pp.41-55
    • /
    • 1989
  • Successive iteration of geometrical optics(GO)is suggested to calculate wedge diffraction fields. For a wedge and given source, the GO field may be obtained when the fields by the half spaces are found and the shadow regions are determined. Furthermore, one may caluculate the sources which are equivalent to the discontinuities of the GO field along the shadow boundaries and form a new wedge problem with the equivalent sources instead of the original one. It is shown that the field by the wedge and the equivalent sources equals to the diffraction field which GO requires for the complete solution. Also, it is shown that the field generated by the equivalent sources in the unbounded space, or the incident field in the new wedge problem, equls to the diffraction field approximated by the physical optics. The new wedge problem is solved here by another application of the GO to approximate the diffraction field and the result is compared with that by the physical optics. For a validity of the successive iteration of GO , infinite iteration of GO is performed analytically and the convergence is examined ofr conducting wedges, of which the exact solution is available.

  • PDF

Investigation and measurement of indoor low voltage powerline impedance for high data rate powerline communications (PLC) (고속 전력선 통신용 옥내 저전압 전력선 임피던스 측정 및 특성 연구)

  • 박영진;김관호
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.8
    • /
    • pp.93-97
    • /
    • 2004
  • Since powerline for powerline communications (PLC) is designed for supplying electric power using 60 Hz wave, they will have different electrical behaviors for high data rate PLC whose bandwidth is allocated between 1 MHz and 30 MHz. Thus, it is necessary to investigate the different properties in this frequency bandwidth for the high data rate PLC. In this paper, low voltage (220V) powerline impedance for indoor high data rate PLC in between 1 MHz and 30 MHz is measured. For measurement a low voltage coupling unit is made and a vector network analyzer is used. A T-equivalent circuit of the low voltage coupling unit is obtained and then powerline impedance is derived by measuring the reflection coefficient of the total powerline network. With the method proposed, impedance is measured in case of a general korean apartment and its property is analyzed. Measurement shows that the average impedance is about 100Ω.

Design and Implementation of an Acoustic Modem for Small Underwater Devices Operating at Shallow Water (얕은 수심에서 동작하는 소형 수중 디바이스를 위한 음향 모뎀 설계 및 구현)

  • Jeon, Jun-Ho;Park, Sung-Joon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.11
    • /
    • pp.110-117
    • /
    • 2012
  • As the demand for underwater systems providing pollution monitoring, marine ecosystem observation, surveillance monitoring is increased, acoustic modem for short-range underwater communication is spotlighted as one of significant research topics. Typically, in shallow water, it is so hard to analyze acoustic wave which undergoes spreading, absorption, reflection and scattering through transmission that there are limited advanced results. Furthermore, in order for the modem to be loaded in a fixed node or a moving vehicle in shallow water, its size should be small enough. In this paper, we address underwater acoustic channel model and design and implement an efficient micro acoustic modem which is adequate for short-range underwater communication. The developed modem is verified in a lake by varying working range and data rate up to 500 meters and 2 kbps, respectively.

Analysis of HEMP Coupling Signal for a Coaxial Cable with Braided Shields (Braided Shield를 가진 동축 케이블의 HEMP 결합 신호 해석)

  • Lee, Jin-Ho;Cho, Jea-Hoon;Kim, Eung-Jo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.790-796
    • /
    • 2011
  • The system which is exposed in the impact range of High-altitude Electromagnetic Pulse(HEMP) may get serious damage because HEMP has a very large electric field value, a very fast rise-time, and so on. Electromagnetic analysis should be performed for signals coupled to the opening or cables of the system prior to derive the system design specifications in order to protect the system against HEMP adequately. In this paper, we analyzed the HEMP coupled signals for the coaxial cable which is generally used to transmit and receive video or RF signals and compared the coupled signal of the one wire with that of the inner conductor of a coaxial cable to confirm the decreased effect of HEMP by the shield. The coaxial cable is analyzed by the external and internal region of the shield separately. For the external region of the coaxial cable, general scattered equation was applied to calculate currents on the surface of the shield and for internal region of the coaxial cable, chain matrix algorithm is used. To verify this paper the analyzed results were compared the results of the existing paper and the two results have good agreements.

Efficient Fault Location Detecting Mechanism for Optical Submarine Cable (해저광케이블 고장지점 탐지기법)

  • Park, Hong-Tae;Yoo, Jae-Duck;Yoon, Suk-Min;Jo, Gi-Rayng;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The optical submarine cable has a long distance cable and the repeater for optical amplification compared to territorial optical cable so conventional OTDR utilization for the optical submarine cable is limited. in case the optical core in the optical submarine cable system cut, by using Coherent OTDR that utilize OTDR path in repeater the cable fault point can be detected and in case the faulty of the copper tube in the cable that provide power for the repeater to amplify optical signal, the ways using the current/voltage characteristic, the capacitance per Km and so on is required. this report suggest efficient fault location detecting mechanism by categorized cable fault type.

  • PDF

Transmission and Histochemical Detection of Mulberry Dwarf Mycoplasma in Several Herbaceous Plants (뽕나무 오갈병 마이코플라스마의 몇가지 초본식물에의 전염과 조직화학적 검정)

  • Kim Young Ho;La Yong Joon;Kim Young Taek
    • Korean Journal Plant Pathology
    • /
    • v.1 no.3
    • /
    • pp.184-189
    • /
    • 1985
  • Transmission of mulberry dwarf mycoplasma (MDM) from diseased mulberry to 5 herbaceous plants (periwinkle, white clover, Ladino clover, red clover, and Chinese milk vetch) through insect vector, Hishimonus sellatus, was confirmed by symptom expression and microscopic evidences. The earliest symptom appearance was noticed on periwinkle in which incubation period was 25-30 days, while it ranged 35-40 days in the other plant species. The common symptoms of MDM infected plants were characterized by poor plant growth with accompanying discolorations of leaves (chlorosis with vein clearing in periwinkle, reddish in red clover, brownish in white and Ladino clovers, and yellowish in Chinese milk vetch). Mycoplasmal infections were diagnosed light microscopically by Dienes' and toluidine blue staining of hand-cut and Epon-embedded sections, respectively. In Dienes' stain, all the plants infected with MDM showed specific staining reaction in phloems. In toluidine blue stain, mycoplasmal existence was noted by granular appearance in sieve tubes which were confirmed to be mycoplasma-like organisms under an electron microscope.

  • PDF

Structure Analysis of Li-ion Battery Using Neutron Beam Source (중성자를 이용한 리튬이온 이차전지 전극 구조분석)

  • Kim, Chang-Seob;Park, Heon-Yong;Liang, Lianhua;Kim, Ji-Young;Seong, Baek-Seok;Kim, Keon
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.20-24
    • /
    • 2007
  • Lithium ion secondary battery has been applied widely to portable devices, and has been studied for application to high power electric cell system such as power tool or hybrid electronic vehicle. The structure change of the electrodes materials occur when lithium ions move between electrodes. Neutron or X-rays can analyze the structure of electrode. The advantage of X-rays is convenient in test. However X-rays is scattered by electron cloud in atoms. Therefore, The elucidation for correct position of lithium is difficult with X-rays because lithium has small atomic weight. Neutron analysis techniques could solve this problem. In this review, We wish to discuss about structure analysis and the principle of structural characterization method using neutron beam source.