• Title/Summary/Keyword: 전자식 안정기

Search Result 337, Processing Time 0.029 seconds

Development and Performance Evaluation of Hydroxyl Radical Generator using Electron Emission Type High Voltage and Low Current Discharger (전자방사식 고압 저전력 방전을 이용한 OH radical 발생기의 개발과 성능 평가)

  • Kang, Hyung-Sub;Hong, Young-Pyo;Lee, In-Ho;Kim, Gi-Beum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.558-566
    • /
    • 2017
  • In this study, we developed an electron-emission OH radical generator for waste water treatment. The stability of the circuitry was ensured by implementing stable pulse waves with a MOSFET and reducing the momentary current rise. The OH radical generator uses a high-voltage and low-current discharger. The performance of the device was evaluated experimentally, which showed that it is possible to produce a stable and uniform pulse waveform for the drain current of the power MOSFET, which is connected to the input side of an AC multiplying converter through negative feedback circuitry with CR-snubber architecture. It was also possible to reduce the excitation current of the converter and improve the stability of the oscillation circuit. In addition, the generator can generate hydroxyl radicals stably. The bactericidal activities were also evaluated, and the germicidal power for E. coli, S. aureus, and S. flexneriwas improved by 99.9% or more after 60 minutes.

The study for Resolution of flicker problems in Electric Multiple Unit fluorescent lamp (전동차 형광등 시스템의 플리커 문제 해결방안에 관한 연구)

  • Cho, Yun-Ok;Lee, Sang-Soo;Park, Chan-Woo
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1477-1482
    • /
    • 2006
  • 플리커란 형광등의 광 출력 변동폭이 큼으로 인해 인간의 눈과 뇌로 이루어진 감각시스템이 불유쾌한 감각을 인지하는 현상이다. 이러한 플리커 현상에 대한 저감 및 감소 대책이 미흡한 실정이며, 인간의 인지 능력 향상을 위해 플리커 문제 해결방안에 대한 연구 수행이 필요하다. 본 논문에서는 플리커를 감소시키기 위한 방법으로 정전력 단권 변압기 회로를 이용한 안정기 적용 방법을 제시하였다. 이 방법은 형상시스템의 전압원이 가변되더라도 형광등에 인가되는 전압을 허용범위 내에서 제어함으로 감소시킬 수 있다. 플리커 현상을 감소시키기 위하여 정전력 단권 변압기 회로를 이용한 안정기 적용법과, 전자식 안정기의 적용법을 제시하였으며, 본 연구에서 제시한 방법을 사용한다면 허용 한계 및 그 이하로 감소시킬 수 있을 것이며, 이를 이용한 장치를 사용하는 곳에서는 인간의 인지 능력을 향상 시킬 수 있을 것으로 사료된다.

  • PDF

The Development of Buck Type Electronic Ballast for 250W MHL and Dimming System (250W MHL용 Buck Type 전자식 안정기 및 Dimming 시스템 개발)

  • 박종연;박영길;정동열;김한수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.30-40
    • /
    • 2002
  • This paper studies the electronic ballast development for 250w MH lamps. We have improved the input power factor using a PFC IC. To provide the rating voltage required In the lamps, we have used the buck type dc-dc converter By this method, the stress of switching devices in inverter can be reduced. The inverter is the Full-Bridge type. To eliminate the acoustic resonance phenomena of MH lamps, we have added the high frequency sinewave voltage to the low frequency square-wave voltage to the lamp. We hove developed the igniter circuit using the L, C devices. We could control dimming of the lamp by varying the output voltage of the buck converter. The time of illuminating lamps and luminous intensity could be adjusted by season and time band. The buck converter output voltage can be controlled and the no load and over current situation were Protected by the development of the microprocessor Program.

Electronic Ballast Design Driven by Low Frequency Square Wave for High Power MHL (고출력 MHL용 구형저주파 구동 방식의 전자식 안정기 설계)

  • Kim, Ki-Nam;Park, Jong-Yun;Choi, Young-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.394-400
    • /
    • 2010
  • In this paper, We proposed electronic ballast that applys Buck Converter operation principle to Full-Bridge inverter. The proposed ballast consists of an EMI Filter, a full-bridge rectifier, a passive power factor correction (PFC) circuit and a full-bridge inverter. The passive PFC is used and a Full-Bridge inverter operation by two frequency. High Side and Low Side switch was driven by high frequency and low frequency and realized buck Converter's operation. The lamp is driven by Low Frequency square wave to avoid Acoustic Resonance. Also, bulk of inductor is reduced by high frequency switching. Performance of the proposed ballast was validated through computer simulation using Pspice, experimentation and by applying it to an electronic ballast for a prototype 700W MHL.

Research of Ignitor and Noise Rejuction for Electronic Ballast of MHD Lamp (MHD 램프용 전자식 안정기의 점화기 및 소음제거에 관한 연구)

  • 정동열
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.74-77
    • /
    • 2000
  • Today there is an ever increasing effort to control high-pressure discharge lamps with electronic ballast. HID lamps can be ignited by high-voltage pulses and need an ignitor to start them. An ignitor gives high-voltage pulses to HID lamps which have the type of the arc discharge. Three kinds of ignitor circuits have been analyzed by the P-spice program and we have shown experimental results in this paper. The result of this study seems to be able to help to develope various ignitors.

  • PDF

Spike Current Control Circuit for Two-stage Low Frequency Square wave Electric Ballast with Zero-Voltage Switching (ZVS를 이용한 2단 저주파 구형파 전자식 안정기의 스파이크 전류 제어)

  • Jung, Woo-Jin;Yoo, Chang-Gyu;Lee, Woo-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.179-181
    • /
    • 2009
  • 고압 방전 램프는 점등 후부터 정상상태에 이르기까지 방전관 내부의 온도 및 압력이 광범위하게 변화하는 복잡한 동작 특성으로 모델링이 어렵다. 이러한 특성은 램프를 구동하는 안정기의 설계에 어려움이 따른다. 램프의 구동에는 초기 점화 시 높은 점화용 전압 펄스를 필요로 한다. 점화 후에 정상상태에 다다르면 램프 전극의 소모를 줄이기 위해 교류로 구동되어야 한다. 하지만 램프를 교류로 구동하게 되면 음향 공진 현상이 발생할 수 있다. 음향 공진 현상은 램프 구동 전류의 맥동성분이 큰 경우에도 발생을 할 수 있으므로 구동 전류의 맥동 성분의 크기는 최소화 돼야 한다. 램프의 수명시간을 길게 하려면, 안정기는 램프를 정격전력으로 구동하여야 한다. 따라서 안정기에서는 정전력 제어가 필요하게 된다. 램프 전류의 극성이 변화할 때, 램프 전류는 spike전류와 중첩이 된다. 본 논문에서는 spike 전류를 저주파구형파 램프 전류의 포락범위 안에 유지하고, 고주파 스위칭시손실을 줄이기 위해 소프트 스위칭 기법을 이용한 회로 설계를 제안했다. 제안된 방법은 시뮬레이션 및 이론적 수식적 방법으로 검증 했다.

  • PDF

Evaporator Superheat Control of a Multi-type Air-Conditioning/Refrigeration System (멸티형 공조/냉동시스템의 증발기 과열도 제어)

  • 김태섭;홍금식;손현철
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.253-265
    • /
    • 2001
  • This paper investigates a PI control problem for the evaporator superheat, i.e., temperature difference between the two-phase region and the exit region of an evaporator, for multi-type air-conditioning/refrigeration system. Mathematical model describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, two transfer function from the current input applied to an electronic expansion valve to the wall-temperatures of an evaporator tube at two-phase region and superheated region, respectively, are derived. The stability of the closed loop system with the PI controller designed it analyzed by using Nyquist stability criterion. Simulation results are provided.

  • PDF

Electrical and optical characteristics of Ceramic metal halide lamp with operating methode (세라믹 메탈할라이드 램프의 구동방식에 의한 전기.광학적특성)

  • Kim, Nam-Goon;Yang, Jong-Kyung;Lee, Joo-Ho;Jang, Heuk-Jin;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1493-1494
    • /
    • 2008
  • 최근 메탈할라이드 램프에서 방전관 재료에 세라믹을 사용하는 세라믹 메탈할라이드 램프가 고연색성과 고효율, 장수명 등의 장점에 을 가지고 있다. 최근 이러한 세라믹 메탈할라이드 램프의 적용이 증가함에 따라 개선을 위하여 계속적으로 방전관 재료, 가스 및 메탈할라이드의 최적화, 구동방식에 따른 특성 등 다양한 요소에 대한 연구가 진행되고 있다. 본 논문은 이러한 세라믹 메탈할라이드의 구동방식에 따른 특성을 알아보기 위하여 자기식 안정기와 전자식 안정기의 구동 시 나타나는 전압, 전류 파형과 광학적 특성, 열적특성을 비교 분석하였다.

  • PDF

냉난방수 순환펌프와 조명기기 교체 에너지절약 위해서 아낌없는 시설투자

  • 에너지절약전문기업협회
    • The Magazine for Energy Service Companies
    • /
    • s.7
    • /
    • pp.26-29
    • /
    • 2000
  • 코리아나호텔은 지난해 11월 절전형 전자식 안정기를 설치하고, 냉난방수 순환펌프를 고효율 펌프로 교체하는 ESCO사업을 진행했다. 이에 앞선 5월에도 기존 백열전구를 삼파장 전구로 교체하여 조명효율을 높인 바 있다. 뿐만 아니라 녹색조명운동을 통한 조명교체사업을 지속적으로 실시하는 등 정부에서 추진하는 에너지절약사업 동참에 앞장서왔다.

  • PDF

Special Member - ESCO 사업으로 희망을 설계하는 두영(주)

  • Choe, Won-Geun
    • The Magazine for Energy Service Companies
    • /
    • s.66
    • /
    • pp.38-41
    • /
    • 2010
  • 24년간 에너절약사업이라는 외길을 걸어온 두영(주). 절전형 전자식 안정기 생산을 시작으로 설립된 두영은 지난해 ESCO기업으로 등록하며 새로운 희망을 설계하고 있다. 특히 국내 최고의 베테랑들로 구성된 에너지사업부는 불과 1년 만에 폐열회수 열교환기 설치공사를 비롯해 굵직한 사업들을 성공적으로 진행하며 ESCO 분야 내 슈퍼루키로 떠올랐다.

  • PDF