Flow Signal Characteristics of Small Scale Electromagnetic Flowmeter in Low Conductivity Fluid Measurement (저전도율 유체 측정에서 소형 전자기유량계의 신호 특성)

  • Lim, Ki Won;Jung, Sung Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.613-620
    • /
    • 2016
  • In order to scrutinize the fluid conductivity effects on the electromagnetic flowmeter(EMF) characteristics, a small scale EMF was designed and fabricated. The measuring tube has a $3mm{\times}4mm$ rectangular cross-section, 9 mm length, and a $2mm{\times}3mm$ plate electrode and a ${\Phi}1.5mm$ point electrode. The design parameters, such as the magnetizing frequency and the number of coil turns, and the diameter were optimized. The EMF was tested with a gravimetric calibrator and showed good linearity in the range of 0 to $1.17{\times}10^{-5}m^3/s$. The fluid conductivity was varied between 3 and $11{\mu}S/cm$, and the magnitude of the flow signal was proportional to the fluid conductivity and the wetted area of the electrode. The design information and the test results provide flow measurement techniques for very low flowrate.

Adaptive TMS Variable Area Flow Meters (적응형 TMS 면적식 유량계)

  • Kwak, Doo-Sung;Kim, On;Cho, Ki-Ryang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.590-595
    • /
    • 2008
  • A new adaptive TMS variable area flow meter that is used to the environment measuring equipment is proposed. This system is consist of a ball moving within the tube line which corresponds to gas flow and photo sensor array which monitoring the movement of ball. This system can monitoring the position of bali in case of the very few gas flow in various levels. And it can automatically adjust the gas flow at the highest and the lowest level to prevent the tube line blockage.

A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume) (방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구)

  • An, Yang-ki;Kim, Jee-young;Kim, Kum-hee;Jang, Hee-soo;Jung, Jung-pil;Choi, Jong-woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.6
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

A Real-Time Measurement of Slug Flow Using Electromagnetic Flowmeter with High frequency Triangular Excitation (고주파 삼각파 여자법을 사용한 실시간 슬러그 유동 측정용 전자기유량계)

  • Ahn, Yeh-Chan;Cha, Jae-Eun;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.11
    • /
    • pp.1570-1577
    • /
    • 2002
  • In order to investigate the characteristics of two-phase slug flow, an electromagnetic flowmeter with 240Hz triangular AC excitation was designed and manufactured. The signals and noise from the flowmeter were obtained, and analyzed in comparison with the observations with a high speed CCD camera. The uncertainty of the flowmeter under single-phase flow was $\pm$ 2.24% in real-time. For two-phase slug flow, electromagnetic flowmeter provided real-time simultaneous measurements of the mean film velocity around Taylor bubble and the relative location and the length of the bubble. Besides, it is an easier and cheaper method for measuring mean film velocity than others such as photochromic dye activation method or particle image velocimetry.

Tracing of the Behavior of Flood Wave Propagation Using LSPIV (LSPIV를 이용한 홍수파의 거동 추적)

  • Kim, Young-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1774-1778
    • /
    • 2008
  • 유량 환산에 이용되는 수위-유량 관계곡선식은 하천의 흐름을 정상 등류상태로 가정하고 유속계를 하천에 투입하여 년간 정해진 횟수의 유량측정을 실시하여 이로부터 갱신하여 작성하고 있다. 평수기에는 이렇게 기기를 이용하여 유량측정이 가능하지만 홍수기나 갈수기에는 접촉식 유속계를 이용한 하천유량 측정이 불가능한 실정이다. 홍수기에는 기기 손상과 관측자의 안전이 위협받는 실정이고, 갈수기에는 유속이 너무 느려서 (0.1 m/s 이하) 프로펠러 유속계의 경우 유속의 정확한 관측이 힘들다. 또한 전지구적 빈번한 이상기후의 현실정에서 가장 중요한 기초 수문자료인 홍수량의 정확한 측정 자료는 많지 않다. 홍수유량을 측정하기 위해서 현재에도 기존의 봉부자를 이용하거나 유비쿼터스 센서를 장착한 봉부자를 이용하는 유량측정 기법이 향해지고 계속적으로 소개되고 있는 실정이지만 봉부자의 특성상 정확한 유량을 계산하기에는 어려움이 많다. 현재 선진국에서는 흐름과 비접촉식 방법을 이용한 하천유량측정 방법이 지난 10 여년간 꾸준이 연구되어 왔다. 그중 대표전인 것이 전자파를 이용한 방법과 영상해석에 의한 방법이다. 전자의 경우 국내에서는 수자원공사에서 10년 이상 연구 개발하여 상품화 시킨바 현업에서 이를 이용하여 홍수유량측정을 실시하고 있다. 후자의 방법은 유체역학 분야에서 흐름해석에 주로 이용되어지던 PIV(particle image velocimetry) 기법을 하천과 같이 대규모의 흐름영역에 적용가능하도록 개발된 기술로 LSPIV (large-casle particle image velocimetry)라 불리우는 기술이다. 본 연구에서는 미국 Iowa 대학에서 개발한 LSPIV를 이용하여 홍수파의 진행시 수위와 유량의 두 변수 사이에 나타나는 Loop rating curve의 이론적인 관계를 하천현장에서 일정시간 간격으로 실측을 통하여 파악하고자 하였다. 현장실험을 위한 대상지점으로 미국 Iowa주 Coralville 시내 Clear Creek의 USGS (US Geologival Survey) 수위관측소 지점을 선택하여 본 연구에서 실시한 유량측정 결과의 비교가 가능토록 하였다. LSPIV는 그 특성상 야간에는 적용하는데 어려움이 있어 아침시간부터 해가 지기 직전까지의 자연채광 조건의 영상취득이 가능한 시간대에서 표면유속을 측정하였고 이에 수심평균유속환산계수를 적용하여 유량을 계산하였다. 강우의 발생으로 인한 홍수파의 진행시 총 43회의 유량을 측정하였는바 이를 이용하여 이 지점의 수위-유량 관계식과 비교한 결과 거의 일치하는 결과를 나타냈다. 특히 홍수파의 진행시 고수위 영역에서의 측정한 결과는 수위의 상승기에는 최고로 7.5% 까지 측정유량이 수위-유량관계식에서 계산한 유량보다 컸으며, 수위의 하강기에는 반대로 최고 5.4% 정도까지 측정유량이 수위-유량관계식에서 계산한 유량보다 작게 나타났다. 또한 최대유량의 발생시기는 최고수위 발생직전의 수위라는 것이 파악되었다. 이러한 경향은 수위-유량 관계곡선의 이론과 잘 일치하는 것이다.

  • PDF

A Study on Error Characteristics of Large Size Electromagnetic Flowmeter in the Range of Low Velocity (저유속 영역에서 대구경 전자기유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • The large size electromagnetic flowmeter was tested to investigate the variation of its error characteristics in the range of low velocity under 0.6 m/s using flowmeter calibration system. For the two case of valve opening rate 100 % and 50 %, these tests were undertaken three times each for twelve velocity condition from $0.05\;^m/s\;to\;0.6\;^m/s$ with increment of $0.05\;^m/s$. It is shown that error characteristic of electromagnetic flowmeter was stabilized within ${\pm}0.4%$ of rate both higher than $0.25^m/s$ of velocity condition and 50 % of valve opening position. But, measurement deviation of flowmeter for ${\Phi}400mm\;and\;{\Phi}600mm$ was out of expected deviation range. It is necessary to correction with calibration. In conclusion, error characteristic of electromagnetic flowmeter wasn't changed proportion to its size.

Experimental study for analysis of hydraulic characteristics around dams (댐 주변의 수리특성 분석을 위한 실험적 연구)

  • Baek, Donghae;Yoon, Jae-Seon;Lee, Byeong Wook;Jang, Eun Cheul;Song, Hyun-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.257-257
    • /
    • 2022
  • 댐 건설은 홍수 및 가뭄에 대응하기 위한 구조적 방법으로써 우리나라와 같이 지표수에 의존적인 지역에서는 가용 수자원을 확보하기 위한 확실한 수단으로 활용되어왔다. 신규 댐의 건설은 대상 하천의 수리학적 특성에 큰 변화를 야기할 수 있으며, 댐의 안정성 및 하천의 하도보호를 위해 댐 주변의 수리적 특성의 변화에 대해서도 사전에 인지하여 설계 시 반영할 필요가 있다. 수공구조물 신설에 따라 변화되는 수리학적 특성을 분석하는 방법으로는 그 수단에 따라 상사법칙을 적용한 수리모형실험과 수치기법을 활용한 수치모형실험으로 나눌 수 있다. 본 연구에서는 수리모형실험을 통한 실험적 방법을 이용하여 댐 상하류 구간의 수리학적 특성을 분석하였다. 해당 실험은 한국농어촌공사 농어촌연구원의 대형수리모형실험시설에서 수행되었다. 적용대상 댐의 제원은 높이 약 70m, 길이 약 230m이며, 폭 55m의 여수로를 포함하는 구조로 설정하였다. 수리모형은 Froude 상사법칙을 적용하여 1/30 규모로 축소하였으며, 콘크리트 및 아크릴 재료를 이용하여 제작되었다. 댐 모형이 설치되는 하천구간은 댐 구조물을 포함하여 실규모를 기준으로 흐름방향으로 약 800m, 하폭방향으로 약 450m의 범위를 포함하도록 설계되었으며, 하류구간에 사행하천이 존재하는 것이 특징이다. 본 실험에서 유량은 총 12개의 펌프를 이용하여 공급되었으며, 최대 4cms에 해당하는 유량공급이 가능하도록 설계하였다. 공급유량은 정교한 절차에 의해 보정된 전자식 유량계를 통해 통제되었으며, 사용된 유량계의 허용오차는 약 0.5% 수준인 것으로 나타났다. 수위 측정은 오차범위 0.05mm 수준의 초음파 수위측정기를 이용하였으며, 유속측정은 약 0.5cm/s의 정확도를 지닌 3차원 전자기 유속계를 이용한 접촉식 측정과 흐름구조 가시화를 위한 비접촉식 입자추적기법을 병행하였다. 실험조건은 실규모 기준으로 방류량 3,000~5,000cms에 대해 수행하였으며, 각 방류량별 댐 상하류의 흐름패턴에 대해 정량적으로 분석하였다.

  • PDF

A Study on the Uncertainty Estimation of Flowmeter Calibrator with Two Master Flowmeters (2개의 기준유량계를 이용한 유량계 교정장치의 측정불확도 평가에 관한 연구)

  • Choi Jong Oh;Lee Woan Kyu;Lim Ki Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1219-1230
    • /
    • 2004
  • Comparing to the gravimetric and volumetric method, the flowmeter calibration based on the master meter method is relatively economical and convenient, especially for high flowrate. The uncertainty of flow quantity and flowrate using the master meter method was evaluated according to the GUM (Guide to the Expression of Uncertainty in Measurement). In order to apply for the wider flow range, two master meters (electromagnetic flow meter) were employed as reference flowmeters. The uncertainty of the master meter was obtained by combining the statistical variation of the repeated measurements and the variation of fluid density and pipe material due to temperature and pressure changes were scrutinized. for a practical application, the uncertainty of calibrator, whose measuring capacity of 1000 ㎥/h obtained by employing two 500 ㎥/h electromagnetic How meters, was evaluated. The uncertainty budget shows the quantitative contribution of each uncertainty component to the overall uncertainty of the calibrator. As a result, it was found that the dominant uncertainties were from the master meter, which was evaluated statistically, and from the process of least squares fitting. On the contrary, the uncertainties arising from the variation of the fluid density and the pipe volume due to the temperature and pressure were negligible.

Design and Fabrication of an Electromagnetic Flowmeter (전자기유량계의 설계 및 제작)

  • Lim, Ki-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1385-1392
    • /
    • 2003
  • An electromagnetic flowmeter(EMF) was developed and its characteristics were compared with a commercial EMF. The developed EMF was designed as the 100 mm nominal diameter. A signal processing circuit was also developed for generating the magnetic field and converting the flow signal to flowrate and flow quantity. In order to obtain a more stable and reliable flow signal, the double magnetizing frequency was adopted for magnetizing the coil of the EMF. For the characterization of the developed EMF, the uncertainty of calibrator was estimated within $\pm$0.5 %. The evaluation procedure of the uncertainty followed the ISO Guide to the Expression of Uncertainty in Measurement. It was found that the flow signals between the electrodes were about $\pm$60-$\pm$300$\mu$V, which were sufficient for the discrimination of flowmeter and the protection of noise. The test results against the calibrator showed the good linearity in the range of 3 ㎥/h and 70 ㎥/h. A commercialized design of the EMF based on the current study will be technically more competitive in domestic and foreign market.

Prediction of Curvature Effects on the Electromagnetic Flowmeter Characteristics with Numerical Simulation (Laminar flow) (곡관의 곡률에 따른 전자기유량계 설치효과의 수치모사에 의한 특성 예측(충류))

  • Lim, Ki Won;Choi, Sang Kyu;Chung, Myung Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1453-1463
    • /
    • 1999
  • An electromagnetic flowmeter, based on a magnetic induction principle; provides an obstructionless flowmeter that essentially averages the velocity distribution over the pipe cross-sectional area. To predict the installation effects, the flowmeter installed near $90^{\circ}$ elbow is simulated by using a commercial code FLUENT(ver. 4.48) for the laminar flow field and a code developed through this study for magnetic field. The installation effects of the flowmeter are estimated by varying a number of the dependent parameters such as the radius of the elbow(Rc=1D, 1.5D, 2D, 3D), the location, Reynolds number and the direction of electrodes plane(${\varphi}$). It was found that all these factors affect the performance of the electromagnetic flowmeter significantly. The longer installation distance from the elbow is not always optimal to minimize the error, and also there exists an optimal location to install the EMF for a minimum error. Especially the flow signal with the electrodes plane direction of ${\varphi}=45^{\circ}$ is shown to yield smallest measurement error regardless of the Reynolds number and the curvature of elbow.