• Title/Summary/Keyword: 전자기 센서

Search Result 796, Processing Time 0.026 seconds

A Study on the Lighting Control System using Fuzzy Control System and RGB Modules in the Ship's Indoor (퍼지 제어 시스템과 RGB LED 모듈을 이용한 선박 실내용 조명 제어 시스템에 관한 연구)

  • Nam, Young-Cheol;Lee, Sang-Bae
    • Journal of Navigation and Port Research
    • /
    • v.42 no.6
    • /
    • pp.421-426
    • /
    • 2018
  • With regard to LED lighting devices which have currently been commercialized, LED operating sequences are being sold in a fixed state. In such a state, the external environmental factors are not taken into consideration as only the illumination environment application is considered. Currently, it is difficult to create an optimal lighting environment which can adapt to changes in external environmental factors in the ship. Therefore, it was concluded that there is a need to input the external environment value so that the optimal illumination value can be reflected in real time in order to adapt more organically and actively to the change of external environmental factors. In this paper, we used a microprocessor as an integrated management system for environmental data that changes in real time according to existing external environmental factors. In addition, a controller capable of lighting control of RGB LED module by combining fuzzy inference system. For this, a fuzzy control algorithm is designed and a fuzzy control system is constructed. The distance and the illuminance value from the external environment element are input to the sensor, and these values are converted to the optimum illumination value through the fuzzy control algorithm, and are expressed through the dimming control of the RGB LED module and the practical effectiveness of the fuzzy control system is confirmed.

Design of a Low-Power 8-bit 1-MS/s CMOS Asynchronous SAR ADC for Sensor Node Applications (센서 노드 응용을 위한 저전력 8비트 1MS/s CMOS 비동기 축차근사형 ADC 설계)

  • Jihun Son;Minseok Kim;Jimin Cheon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.6
    • /
    • pp.454-464
    • /
    • 2023
  • This paper proposes a low-power 8-bit asynchronous SAR ADC with a sampling rate of 1 MS/s for sensor node applications. The ADC uses bootstrapped switches to improve linearity and applies a VCM-based CDAC switching technique to reduce the power consumption and area of the DAC. Conventional synchronous SAR ADCs that operate in synchronization with an external clock suffer from high power consumption due to the use of a clock faster than the sampling rate, which can be overcome by using an asynchronous SAR ADC structure that handles internal comparisons in an asynchronous manner. In addition, the SAR logic is designed using dynamic logic circuits to reduce the large digital power consumption that occurs in low resolution ADC designs. The proposed ADC was simulated in a 180-nm CMOS process, and at a 1.8 V supply voltage and a sampling rate of 1 MS/s, it consumed 46.06 𝜇W of power, achieved an SNDR of 49.76 dB and an ENOB of 7.9738 bits, and obtained a FoM of 183.2 fJ/conv-step. The simulated DNL and INL are +0.186/-0.157 LSB and +0.111/-0.169 LSB.

Gait Phase Recognition based on EMG Signal for Stairs Ascending and Stairs Descending (상·하향 계단보행을 위한 근전도 신호 기반 보행단계 인식)

  • Lee, Mi-Ran;Ryu, Jae-Hwan;Kim, Sang-Ho;Kim, Deok-Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.181-189
    • /
    • 2015
  • Powered prosthesis is used to assist walking of people with an amputated lower limb and/or weak leg strength. The accurate gait phase classification is indispensable in smooth movement control of the powered prosthesis. In previous gait phase classification using physical sensors, there is limitation that powered prosthesis should be simulated as same as the speed of training process. Therefore, we propose EMG signal based gait phase recognition method to classify stairs ascending and stairs descending into four steps without using physical sensors, respectively. RMS, VAR, MAV, SSC, ZC, WAMP features are extracted from EMG signal data and LDA(Linear Discriminant Analysis) classifier is used. In the training process, the AHRS sensor produces various ranges of walking steps according to the change of knee angles. The experimental results show that the average accuracies of the proposed method are about 85.6% in stairs ascending and 69.5% in stairs descending whereas those of preliminary studies are about 58.5% in stairs ascending and 35.3% in stairs descending. In addition, we can analyze the average recognition ratio of each gait step with respect to the individual muscle.

Development of a Low-cost Monocular PSD Motion Capture System with Two Active Markers at Fixed Distance (일정간격의 두 능동마커를 이용한 저가형 단안 PSD 모션캡쳐 시스템 개발)

  • Seo, Pyeong-Won;Kim, Yu-Geon;Han, Chang-Ho;Ryu, Young-Kee;Oh, Choon-Suk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.61-71
    • /
    • 2009
  • In this paper, we propose a low-cost and compact motion capture system which enables to play motion games in PS2(Play Station 2). Recently, motion capture systems which are being used as a part in film producing and making games are too expensive and enormous systems. Now days, motion games using common USB camera are slow and have two-dimension recognition. But PSD sensor has a few good points, such as fast and low-cost. In recently year, 3D motion capture systems using 2D PSD (Position Sensitive Detector) optic sensor for motion capturing have been developed. One is Multi-PSD motion capture system applying stereo vision and another is Single-PSD motion capture system applying optical theory ship. But there are some problems to apply them to motion games. The Multi-PSD is high-cost and complicated because of using two more PSD Camera. It is so difficult to make markers having omni-direction equal intensity in Single-PSD. In this research, we propose a new theory that solves aforementioned problems. It can measure 3D coordination if separated two marker's intensity is equal to. We made a system based on this theory and experimented for performance capability. As a result, we were able to develop a motion capture system which is a single, low-cost, fast, compact, wide-angle and an adaptable motion games. The developed system is expected to be useful in animation, movies and games.

A Case Study on Field Campaign-Based Absolute Radiometric Calibration of the CAS500-1 Using Radiometric Tarp (Radiometric Tarp를 이용한 현장관측 기반의 차세대중형위성 1호 절대복사보정 사례 연구)

  • Woojin Jeon;Jong-Min Yeom;Jae-Heon Jung;Kyoung-Wook Jin;Kyung-Soo Han
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1273-1281
    • /
    • 2023
  • Absolute radiometric calibration is a crucial process in converting the electromagnetic signals obtained from satellite sensors into physical quantities. It is performed to enhance the accuracy of satellite data, facilitate comparison and integration with other satellite datasets, and address changes in sensor characteristics over time or due to environmental conditions. In this study, field campaigns were conducted to perform vicarious calibration for the multispectral channels of the CAS500-1. Two valid field observations were obtained under clear-sky conditions, and the top-of-atmosphere (TOA) radiance was simulated using the MODerate resolution atmospheric TRANsmission 6 (MODTRAN 6) radiative transfer model. While a linear relationship was observed between the simulated TOA radiance of tarps and CAS500-1 digital numbers(DN), challenges such as a wide field of view and saturation in CAS500-1 imagery suggest the need for future refinement of the calibration coefficients. Nevertheless, this study represents the first attempt at absolute radiometric calibration for CAS500-1. Despite the challenges, it provides valuable insights for future research aiming to determine reliable coefficients for enhanced accuracy in CAS500-1's absolute radiometric calibration.

Design and Verification of Ceramic Heating Element-based Tankless Instant Electric Water Heater (세라믹 발열체기반 비저장식 순간 전기 온수기 개발 및 검증)

  • Ahn, Sung-Su;Kim, Woo-Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.11
    • /
    • pp.151-159
    • /
    • 2016
  • This paper proposes a ceramic heating element-based tankless instant electric water heater for hand/face washing that does not require a lot of hot water. The heating module, which heats the input water and outputs hot water, operates the ceramic heating element detecting input water using a flow sensor. Inside of the heating module is designed to form one flow path in order to get almost $15^{\circ}C$ increased heated water compared to the input water temperature within 2 second after 1.5 liter per minute water supply. The design validity is verified using a heat flow analysis of the water flow and temperature variations inside of the heating module also. Based on the design data, the heating module is constructed including a single rod-type ceramic heating element. After that, a prototype system having temperature setting function by three steps were constructed. The prototype system is connected to a 1.5 liter per minute water supply line, and the water output temperature and time measurement experiments confirmed that the proposed system output the heated water increased by $18.3^{\circ}C$ in case of third step setting within 2 second after water supply. And standby power is under 1 W and peak power does not exceed the permissible range for the general house usage. Several performance results verify that the proposed tankless instant electric water heater is applicable for the washstand of the house, highway rest area and factory so on as winter-time hand/face washing.

Evaluation of Piezoelectric Transformer Fabricated with PNN-PMN-PZT Ceramics (PNN-PMN-PZT계 소결체를 이용한 압전트랜스포머 제작 및 특성평가)

  • Ahn, Sang-Ki;Lee, Myung-Woo;Kim, Sung-Jin;Ryu, Sung-Lim;Kweon, Soon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.158-158
    • /
    • 2009
  • 기계적 에너지를 전기적 에너지로 변환하는 에너지 변환소자인 압전 세라믹스는 액추에이터, 변압기, 초음파모터 및 각종 센서로 응용되고 있으며, 그 응용분야는 크게 증가하고 있다. 최근에는 이러한 압전 소자를 앞으로 도래하는 ubiquitous, 무선 모바일 시대의 휴대용 전자제품, robotics 등의 분야에 적용하기 위하여 소형화 및 경량화를 구현하고자 다양한 연구가 진행되고 있다. 본 연구에서는 압전 특성이 우수한 PNN-PMN-PZT 삼원계 세라믹을 이용하여 압전 트랜스포머를 제작하고 전기적 특성을 평가하였다. 압전트랜스포머는 전왜-압전효과를 이용한 소전력용 고전압발생소자로서 종래의 권선형 트랜스포머에 비교해서 소형, 경량이면서 승압비가 높고 구조가 간단하므로 직류 고전압전원에 응용되고 있다. 압전트랜스의 이론적인 고찰은 Rosen 이후로 많은 연구자들에 의해서 보고되었다. 그런데 압전세라믹트랜스는 공진 시 강력한 에너지변환을 하기 때문에 재료의 물리적 특성이 매우 중요함에도 불구하고, 이러한 물리적 특성에 관한 연구는 거의 없었다. 따라서 본 연구에서는 물리적 특성과 전기적 특성의 상호 연관성을 고찰하고자 하였다. 압전트랜스용 재료는 전기기계결합계수($k_p$)와 기계적품질계수(Qm)가 높아야 한다. 전기기계결합계수를 높이기 위해서는 상경계 조성의 Pb(Zr,Ti)$O_3$[PZT]계 세라믹스가 가장 우수하다. 본 연구에서는 기계적 품질계수를 향상시키기 위해서 $Pb(Nn_{1/3}Nb_{2/3})_{0.06+x}(Mn_{1/3}Nb_{2/3})_{0.065-x}(Zr_{0.48}Ti_{0.52})_{0.875}0_3$계의 조성을 설계하여 압전특성을 평가하고 미세구조를 분석하였다. 또한 압전트랜스를 제작하여 입출력의 승압비 및 주파수 특성 등도 평가하였다.

  • PDF

The development of pH reading system based on vision system (영상 기반 pH 산도 측정 시스템 개발)

  • Moon, Ha-Jung;Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.398-406
    • /
    • 2013
  • Nuclear medicine imaging devices such as PET diagnose disease after injecting radiopharmaceuticals in human body for diagnosis. Radiopharmaceuticals should maintain the proper pH for human body safety. In general, pH paper is used to measure the pH of the radiopharmaceutical. pH of the sample compared with the standard color chart is used for measurement. However, the pH reading difference according to the experience of a rater can be generated. Also, a pH meter for measuring pH has a high sensitivity and contamination of the sensor must be avoided. In this paper, we developed the new hardware device for pH reading method and software was developed with vision algorithm to measure pH easily and simply.

Development of an Anaesthesia Ventilator by Volume Control Method and a Gas Monitoring System (가스 모니터 및 볼륨 제어 방식의 마취기용 인공 호흡기 개발)

  • Lee, Jong-Su;Seong, Jong-Hun;Kim, Yeong-Gil
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.37 no.4
    • /
    • pp.42-48
    • /
    • 2000
  • Generally an operator would take notice at putting a patient under anesthesia. If the operation is executed in mistake, the patient is exposed to danger. The object of this Paper is that a system is developed for an accuracy of system and a convenience of user interface to prevent an operation of several elements of risk by mistake. The part of electrical system particularly is made for convenience of a manipulation using electrical switch and encoder. A real-time monitoring system is developed for an airway pressure and a gas concentration of carbon dioxide of patient using graphic LCD(liquid crystal display). Moreover, this flow control system could be developed control with accuracy by feedback control method. This is implemented using flow control valve and flow sensor. The implemented system gives convenience and precision of a manipulation of variable value using developed technique. This system shows guaranteed stabilization and confidence of anesthesia ventilator by notifying us that patient's state and information in case of being out of alarm range of variable value.

  • PDF

Some case histories to detect underwater buried objects by electrical and magnetic methods (수중 매장물 조사에 응용되는 전기 및 자기 탐사사례)

  • JUNG Hyun Key;Park Yeong-Sue;Lim Mutaek;Rim Hyoungrae
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.118-137
    • /
    • 2004
  • Recently underwater geophysical problems for historical relics or UXO's are raised frequently. This study includes the applicabilities and limitations of the recent underwater metal detector and domestic case stories for underwater survey by electrical and magnetic method. Direct or indirect case stories are electrical and vertical magnetic gradiometry surveys beneath Han-river bottom for planning subway tunnel, electrical exploration on lake-bottom, electrical exploration on the tidal flats using high-power transmitter, and borehole three-component magnetic and electromagnetic surveys for detecting the undersea objects. A design of potable real-time, high-speed measurement system using multi-channel array sensors is also introduced here. Further study will be focussed on practical field applications of the fast water-bottom scanning system which is lately required by actual field.

  • PDF