• Title/Summary/Keyword: 전자근관장 측정기

Search Result 18, Processing Time 0.018 seconds

ONE-VISIT ROOT CANAL TREATMENT USING ELECTRICAL APEX LOCATOR IN A CEREBRAL PALSY PATIENT (전자근관장 측정기를 이용한 뇌성마비 환자의 재근관치료)

  • Park, Jin-Sung;Lee, Seung-Jong
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.3 no.2
    • /
    • pp.97-100
    • /
    • 2007
  • In patients with cerebral palsy, dental treatments, which require absolute patient's corporation, have many difficulties because of muscle spacity, involuntary muscle movements and spasm. Especially in endodontic treatments which very meticulous instrumentation is needed, these muscle discordances may lead to unexpected accidents such as tissue damage while filing, over-instrumentation and swallowing instruments. Also, taking radiographs for measuring canal length is often hindered by walking and movement disorders. This paper is to present a clinical case of one-visit root canal treatment using electrical apex locator under general anesthesia in a cerebral palsy patient.

  • PDF

THE EFFECT OF THE CANAL IRRIGANTS ON THE ELECTRONIC WORKING LENGTH DEVICE (전자 근관장측정기 사용에 있어서 근관세척제의 사용이 측정에 미치는 영향에 관한 연구)

  • Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.2
    • /
    • pp.127-133
    • /
    • 1990
  • Electronic working length determination is based on the electrical impedence between the root canal and the periodontal ligament Different canal irrigants with different electric conductivity may effect on the accuracy of the electronic mechanism. 0.9% Saline, 2.5% NaOCl and 3% $H_2O_2$ were evaluated either in wet or in dry condition. The results were as follows. 1. The electrical resistance mearured by Impedence Meter (Model #253, portland, USA) were 1 $K{\Omega}$ in 0.9% Saline, 0.1$K{\Omega}$ in 2.5% NaOCl and 48 $K{\Omega}$ in 3% $H_2O_2$. 2. Saline measured -0.57mm from the actual canal length and had significant difference. When dried with paper points, however, it measured -0.25mm demonstrating no statistical difference. 3. 2.5% NaOCl measured -4.07mm in wet and -2.26mm in dry condition and both showed significant difference from the actual canal length. 4. 3% $H_2O_2$ measured +0.02mm in wet and -0.09mm in dry canals and both appeared to be within acceptable range for the electronic working length mechanism.

  • PDF

Development of Frequency Dependent Type Apex-Locator Improvementation by Auto-calibration Using Impedance Difference (주파수 의존형 전자근관장측정기 개발 및 임피던스차를 이용한 자동보정에 의한 성능향상)

  • Nam, K.C.;Kim, S.C.;Kim, D.W.;Lee, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.399-402
    • /
    • 1997
  • It is important to find a accurate root canal length or successful endodontic therapy. By X-ray method takes a long time and difficult in a curved canal. After developed electronic apex locator has allowed to measure the root canal length with easy, in a short time also in a curved canal. But most electronic apex locators have the disadvantage which is too short reading or sometimes the measurement itself becomes impossible if there are electrolytes in the canal. To overcome this drawback, impedance ratio method has been developed. In this study, we have developed frequency dependent electronic apex locator to minimize the interference of electrolytes. And based on that also some error in clinic use, we added the other method. Difference of two signals which are used in calculation of impedance ratio was can be represent the status of root canal fluid. As a result, using impedance ratio method and auto-calibration by voltage difference method can reduce the measurement error.

  • PDF

DEVELOPMENT OF NEW FREQUENCY-DEPENDENT TYPE APEX LOCTOR ; VOLTAGE DIFFERENCE COMPENSATING TYPE (주파수의존형 전자근관장측정기의 개발과 정확도에 관한 연구 ; 전압차 자동보정형)

  • Lee, Seung-Jong;Kim, Deok-Won;Nam, Ki-Chang
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.2
    • /
    • pp.809-819
    • /
    • 1997
  • The purpose of this study was to develop an accurate frequency-dependent type apex locator. To compensate the impedence differences of different canal contents, voltage differences were pre-measured and stored for saline, HOsb1/$2O_2$ and NaOCl. The circuit was adjusted to recognize the different voltages of each solution, thereby the machine could automatically compensate the voltage differences. In the process of this study, the following informations were observed. 1. Most stable apical reading was obtained at 500Hz and 10kHz. 2. There were no differences in accuracy among three different frequency types, sign wave, triangular wave and rectangular wave(p>0.05). 3. Before the compensation of voltage differences, saline, H2O2 and NaOCl showed different readings at the apex even with the frequency-type (p<0.05). 4. After compensating the voltage difference, the accuracy was enhanced from + 0.42 to +0.32 in H2O2(p<0.05), from -0.34 to -0.12 in NaOCl(p<0.05).

  • PDF

EVALUATION OF THE ACCURACY OF THE ELECTRONIC APEX LOCATOR USING THE POLARIZING MICROSCOPE (편광현미경을 이용한 전자적근관장측정기의 정확성에 관한 연구)

  • Park, Han-Soo;Yoon, Soo-Han
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.235-243
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of an electronic apex locator, the Neosono - M, in determining the location of the cementodentinal junction. A total of 26 teeth with 46 canals were evaluated. The apex locator was used to locate the file and the teeth extracted. The specimen were prepared with highspeed burs and sandpaper discs to a thickness of $250{\sim}300{\mu}m$. Distances were measured from the cementodentinal junction with the use of polarizing microscope. Measurements made by the apex locator were also compared with those by the X - ray. The results were as follows. 1. The apex locator and X - ray were to measure a mean value of 0.17, 0.45mm coronal to the CDJ respectively. There was no significant difference between the accuracy of the apex locator and that of X - ray. 2. There was no significant difference between the accuracy of apex locator in vital and in nonvital teeth, and between in narrow and in wide canals. 3. The files in nonvital and narrow group were apical to the CDJ significantly than those of vital and narrow, vital and wide, and non vital and wide groups.

  • PDF

IN VIVO EVALUATION OF ACCURACY OF TWO ELECTRONIC APEX LOCATORS (전자근관장 측정기의 정확도에 관한 연구)

  • Kim, Hee-Jung;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.289-299
    • /
    • 1996
  • It is necessary to measure the length of a root canal in order to attain a satisfactory prognosis after root canal therapy. There are several methods for determining root canal length, such as tactile sensation by the dental practitioner, the utilization of x-ray film, and electronic root canal measurement. Among these, the electrical measurement methods, in which the impedence between the oral mucous membrane and periodontal membrane is determined, have advantages of simplicity and accuracy. During root canal treatment, the root canal contains a solution of high electrical conductivity such as pus, blood, sodium hypochlorite and so on. Recently a new electronic root canal measurement device of frequency-dependent type has been developed, which is capable of measuring the length of root canal under moist conditions. Endex and Root ZX, which are frequency-dependent type, were evaluated for accuracy of measuring root canal length in vivo by stereomicroscope. The result were as follows ; 1. 82.5% of Endex and 87.5% of Root ZX measured in the range of ${\pm}0.5$ mm from the apical foramen and both showed 57.5 % in the range of 0.1 mm to 0.5 mm. 2. Endex showed significantly higher accuracy in vital teeth than nonvital teeth(p<0.05). But in case of Root ZX, there was no significant difference between vital and nonvital teeth. 3. As a result of this study, there was no significant difference in accuracy between Endex and Root ZX, and both devices showed file passes the apical foramen in more than half of the cases, and it is thought that this must be considered clinically.

  • PDF

The accuracy of the frequency dependent type apex locator (주파수의존형 전자근관장측정기의 정확도에 관한 연구)

  • Park, Ju-Huun;Roh, Byoung-Duck;Lee, Seoung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.150-160
    • /
    • 1996
  • The present study was to evaluate the accuracy of the frequency dependent type apex locator, Root-ZX. The subjects included 505 root canals of 238 teeth treated by the Department of Conservative Dentistry, and 22 human premolars which were schduled to be extracted for the orthodontic reasons. The results were as follows ; 1. The working lengths determined by Root-ZX were compared with radiographic readings. Of the total 505 root canals, 66 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.13mm{\pm}1.05$ longer than those of radiographic readings. 2. The length difference between the file tip determined by Root-ZX and the apical constriction in extracted teeth were measured. Of the total 24 root canals, 70.8 % showed coincidence within ${\pm}0.5mm$ and the average readings of Root-ZX were $0.12mm{\pm}0.50$beyond the apical constriction. 3. The vitality of the teeth did not show any statistical difference(p>0.05) in the accuracy of the Root-ZX readings. The presence of the periapical lesions, however, significantly lowered the percentage of ${\pm}0.5mm$ accuracy in Root-ZX measurements.(p<0.05). In the presence of periapical lesions, the percentage within ${\pm}0.5mm$ was significantly lower.

  • PDF

AN IN VITRO EVALUATION OF THE ACCURACY OF ROOT ZX ELECTRONIC APEX LOCATOR (전자근관장측정기 Root ZX의 정확도에 관한 실험적 연구)

  • Kang, Dae-Hoon;Chung, Kwang-Hee;Yoon, Soo-Han;Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.339-345
    • /
    • 1998
  • The purpose of this study was to evaluate the in vitro accuracy of Root ZX(Morita Co., Japan) which is the ratio type electronic apex locator. The 86 extracted human palatal roots of maxillary molar with fully formed apices were used. File lengths with the file tip just visible at the foramen were compared to those measured with Root ZX. For length measuring with Root ZX, saline test model with which the apical 1/3 of each root was submerged into normal saline were designed. The root canal lengths were determined with Root ZX and the radiographs were taken with a file in the canal. The distances from file tips of Root ZX lengths to apecies in radiographs also were measured with Profile projector PJ311(Mitutoyo Co., Japan). The results were as follows : 1. The root canal length determined with electronic apex locator was $0.78{\pm}0.53mm$ shorter than the length with visual measurement. 2. The file tip of Root ZX lengths was located at $0.85{\pm}0.49mm$ away from the apex in radiograph. 3. The accuracy of the Root ZX was 79.1% within 0.5mm of visual working length and 96.5% within 1.0mm.

  • PDF