• Title/Summary/Keyword: 전응집

Search Result 225, Processing Time 0.025 seconds

Analysis of domain required for aggregates formation of ALS (Amyotrophic lateral sclerosis)/FTD (Frontotemporal dementia)-linked FUS in mammalian cells (루게릭병 및 전측두엽성 치매 연관 단백질 Fused in Sarcoma (FUS)의 스트레스 응집체 형성에 관여하는 도메인 분석)

  • Jun, Mi-Hee;Lee, Jin-A
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.331-340
    • /
    • 2015
  • Mutations in Fused in Sarcoma (FUS) have been identified in patients with amyotrophic lateral sclerosis (ALS) or Frontotemporal Dementia (FTD). Pathological FUS is mis-localized to cytosol and forms aggregates associated with stress granules (SG), while FUS is normally localized to nucleus. However, it is largely unknown how pathological FUS forms SG-aggregates and which domains are responsible for this process. In this study, we examined cellular localization and aggregation of ALS-linked FUS missense mutants (P525L, R521C, R521H, R521G), analyzed the domains responsible for cytosolic FUS aggregation in HEK293T cells, and confirmed this in cultured mouse neurons. To do this, we firstly generated missense mutants of FUS and then examined their cellular localization. We found that P525L was mostly mis-localized to cytosol and formed FUS-positive SG aggregates while R521C, R521H, or R521G was localized to both nucleus and cytosol. To further characterize the domains required for aggregate formation of cytosolic FUS, we generated different domain-deletion mutants using FUS-∆17 which has a deletion of nuclear localization signal. Interestingly, cytosolic FUS without SYGQ and RGG1 domain or cytosolic FUS without RGG2-ZnF-RGG3 domain did not form FUS-positive SG aggregates, while cytosolic FUS without RRM domain generated more aggregates compared to FUS-∆17. Taken together, these data suggest that SYGQ-RGG1 or RGG2-ZnF-RGG3 domain contributes to formation of cytosolic aggregate, while RRM domain might interfere with FUS aggregation. Therefore, our studies will provide important insight for understanding cellular pathogenesis of neurodegeneration associated with FUS aggregate as well as finding therapeutic targets for ALS or FTD.

Carboxyethylgermanium sesquioxide(Ge-132)가 cyclophos-phamide로 유발된 마우승의 면역독성에 미치는 효과

  • 표명윤;오현정
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.320-320
    • /
    • 1994
  • Carboxyethylgermanium sesquioxide(Ge-132)를 투여용량(300,600, 900mg/kg)과 투여일을 변화시켜 정상마우스와 cyclophosphamide(CY)로 처리한 마우스에 경구투여한 후, Ge-132가 CY 에 의해 변화된 마우스의 면역기능에 미치는 효과를 실험하였다. SRBC 항원 주사전, 동시 또는 후에 Ge-132를 투여시 SRBC에 대한 적혈구 응집소가와 비장세포의 용혈반 형성세포(PFC)수가 항원 주사일과 관계없이 용량의존적으로 증가되어 체액성 면역반응을 강화시켰으며, 마크로파지의 탐식능도 항진시켰다. 그러나 DNFB에 대한 접촉성 지연형 과민반응은 DNFB 감작일과 투여용량에 관계없이 Ge-132투여로 억제되었다. CY를 투여한 마우스에 Ge-132를 병용 투여한 군이 CY 단독 투여군에 비하여 적혈구 응집소가와 PFC수 및 혈중 탄소입자의 제거율이 현저하게 증가되어, CY로 억제된 체액성 면역반응과 마크로파지의 탐식능이 항진된 것으로 나타났다. DNFB 감작 전 CY 투여로 증폭된 접촉성 지연형 과민반응이 Ge-132 병용투여로 감소되어 CY로 유도된 면역독성 반응에 대한 Ge-132의 저지효과를 시사해 주었다.

  • PDF

Determination of the Coagulant Injection Methods for Efficient Treatment of Industrial Wastewater (산업폐수의 효율적 처리를 위한 응집제의 주입방법 결정)

  • Park, Se-Jin;Jung, Byung-Gil
    • Journal of the Korean Society for Environmental Technology
    • /
    • v.19 no.6
    • /
    • pp.570-575
    • /
    • 2018
  • The various of raw wastewater inflows to the industrial wastewater treatment plants everyday. This makes it difficult to operate the coagulation and flocculation efficiently as a pretreatment process for the industrial wastewater treatment. Additionally, it causes loads on evaporation and membrane facilities which are the posttreatment and alternative processes. For this reason, this study sampled raw wastewater before and after the NaOH injection. An experiment was conducted to compare the coagulation characteristics according to the methods of coagulant injection (single injection, simultaneous injection, consecutive injection, and inverse injection) aiming at efficient treatment of industrial wastewater. The coagulation experiment was conducted using a jar tester. The TDS removal efficiency by the coagulant injection methods increased in the order of consecutive injection (2.8 %) < single injection (3.9 %) < simultaneous injection(8.1 %) < inverse injection(9.6 %); the TOC removal efficiency grew in the order of single injection (84.3 %) < inverse injection (86.2 %) < consecutive injection (88.6 %) < simultaneous injection (89.1 %); the turbidity removal efficiency grew from single injection (99.7 %) < consecutive injection (99.8 %) ${\fallingdotseq}$ inverse injection (99.8 %) < simultaneous injection (99.9 %). These results show that the simultaneous inorganic coagulant-polymer coagulant injection method was more efficient than the consecutive injection method (inorganic coagulant ${\rightarrow}$ polymer coagulant).

A Study on Coagulation and Ozone Treatment of Nonbiodegradable Substances in Landfill Leachate (생물학적 난분해성물질을 함유한 매립장 침출수의 응집 및 오존처리에 관한 연구)

  • Kim, Jong Shik;Choi, Joon Ho
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.330-335
    • /
    • 1998
  • The objectives of this study are summarized with two. The one is to remove of $COD_{Cr}$, color and turbidity with coagulation and ozonation in nonbiodegradable landfill leachate, the other is to compare of water qualities with pre-ozonation and post-ozonation. The results are summarized as follows ; 1) 90 minutes ozonation with $75mgO_3/min$($4.5gO_3/hr$) was conducted at pH 4,7, 10 to remove $COD_{Cr}$. Removal efficiencies were investigated with 48.2%, 52.6%, and 62.3% respectively. As increasing pH, $COD_{Cr}$ removal efficiencies were increased, it was considered that hydroxyl radical($OH{\cdot}$) which strongly oxdize and nonselectively react with organic compounds, was rapidly produced by ozone self-decomposition at high pH. 2) Alum, ferric chloride and ferrous sulfate were used for coagulation as inorganic coagulant. Ferric chloride was investigated with optimal coagulant, and it removed $COD_{Cr}$ about 12.0% at pH5 and dosage of $2,000m{\ell}/{\ell}$. Cation(C-101P), anion(A-601P) and nonion(SC-050) were tested to remove organic pollutants in landfill leachate. Cation(C-101P) was investigated with the most effective organic coagulant, and removal efficiency of $COD_{Cr}$ was 19.8% at pH5 and dosage of $100m{\ell}/{\ell}$. 3) Color and turbidity were removed up to 88.6%, 97.0% at pH10, when contacted 90 minutes with ozone, respectively. These removal efficiencies were much higher than those of $COD_{Cr}$ and $COD_{Mn}$. It was considered that ozone could oxdize the triggering materials of color and turbidity selectively and preferentially. 4) $COD_{Cr}$, color and turbidity were more effectively removed with pre-ozonation than post-ozonation about 8%, 3.5% and 1% respectively. These results were well corresponed with other's studies that pre-ozonation will increase the effect of coagulation.

  • PDF

Removal of Dissolved Organic Nitrogen from Surface Water and Reclaimed Water by Coagulation (지표수 및 재이용수내 용존 유기질소의 응집처리)

  • Lee, Wontae;Choi, June-Seok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.729-734
    • /
    • 2012
  • During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.

Enhanced total phosphorus removal using a novel membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation (유입흐름 변경 및 전응집 기반 이단응집 제어 적용 MBR을 통한 총인처리 개선 연구)

  • Cha, Jaehwan;Shin, Kyung-Suk;Park, Seung-Kook;Shin, Jung-Hun;Kim, Byung-Goon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.103-114
    • /
    • 2017
  • A membrane bioreactor by sequentially alternating the inflow and by applying a two-stage coagulation control based on pre-coagulation was evaluated in terms of phosphorus removal efficiency and cost-savings. The MBR consisted of two identical alternative reaction tanks, followed by aerobic, anoxic and membrane tanks, where the wastewater and the internal return sludge alternatively flowed into each alternative reaction tank at every 2 hours. In the batch-operated alternative reaction tank, the initial concentration of nitrate rapidly decreased from 2.3 to 0.4 mg/L for only 20 minutes after stopping the inflow, followed by substantial release of phosphorus up to 4 mg/L under anaerobic condition. Jar test showed that the minimum alum doses to reduce the initial $PO_4$-P below 0.2 mg/L were 2 and 9 mol-Al/mol-P in the wastewater and the activated sludge from the membrane tank, respectively. It implies that a pre-coagulation in influent is more cost-efficient for phosphorus removal than the coagulation in the bioreactor. On the result of NUR test, there were little difference in terms of denitrification rate and contents of readily biodegradable COD between raw wastewater and pre-coagulated wastewater. When adding alum into the aerobic tank, alum doses above 26 mg/L as $Al_2O_3$ caused inhibitory effects on ammonia oxidation. Using the two-stage coagulation control based on pre-coagulation, the P concentration in the MBR effluent was kept below 0.2 mg/L with the alum of 2.7 mg/L as $Al_2O_3$, which was much lower than 5.1~7.4 mg/L as $Al_2O_3$ required for typical wastewater treatment plants. During the long-term operation of MBR, there was no change of the TMP increase rate before and after alum addition.

Diagnostic Significance of Cold Agglutinin and Antimycoplasma Antibody for Mycoplasma pneumoniae Infection (항Mycoplasma 항체와 한냉응집소에 의한 Mycoplasma pneumoniae의 진단학적 의의)

  • Kim, Chung-Sook;Lee, Chae-Hoon;Jeon, Chang-Ho;Bae, Eun-Kyung;Hong, Seak-Il
    • Journal of Yeungnam Medical Science
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 1987
  • A Study to evaluate the diagnostic significance of M. pneumoniae infection by measurements of cold agglutinin and antimycoplasma antibody titers is performed with 191 pediatric patients who have visited Yeungnam University Hospital during the period through January to July, 1987. Forty eight of 191 cases made follow up tests feasible. The results obtained are as follows : 1. It is necessary to perform routine combined measurements of cold agglutinin and antimycoplasma antibody titers for the all pediatric pneumoniae caser since a large proportion of pneumonia in children is caused by M. pneumoniae. 2. For the diagnosis of M. pneumoniae infection, measurements of cold agglutinin titers alone seems to be les significant than to check both cold agglutinin and antimycoplasma antibody titers. 3. The measurement of antimycoplasma antibody titer appeared to be more specific than cold agglutinin test in the diagnosis of M. pneumoniae infection. 4. The present study urges the necessity of follow up study of cold agglutinin and antimycoplasma antibody titers for those who initially presented with normal titers in both tests, but are clinically suspected for M. pneumoniae infection.

  • PDF

Aggregation of Thin Copper Wire by Ball Milling Treatment (볼밀처리에 의한 구리세선의 응집)

  • Hwang, Jisu;Cho, Seong Su;Seong, Chang Jun;Yoo, Kyoungkeun
    • Resources Recycling
    • /
    • v.29 no.4
    • /
    • pp.67-72
    • /
    • 2020
  • Recycling processes of spent copper wires cosisnt of several steps of cutting and chopping processes for peeling covering materials followed by gravity separation processes, where copper is recovered. Because copper thin wires could be lost during further recycling processes, the wire may need to be further treated. In the present study, the copper thin wire was treated with ball milling to prevent the loss. Since the aggregation of the copper wire could be formed by bending and entangling the copper wire each other, the degree of flexion of the copper wire was measured after ball milling. When the 0.5 cm and 3 cm copper wires were used, the 0.5 cm copper wire was not bent and the 3 cm copper wires were aggregated regardless of the ball addition. When the 1 cm and 2 cm copper wires were used, the degree of flexion was remarkable when the balls were added. In the tests using 2 cm copper wires, the aggregation ratio of the copper wire gradually increased with the amount of the 20 mm alumina ball, and when 200 ml of 30 mm alumina ball was used, the aggregation ratio increased to 89.29 %, but after increasing the ball amount further, the aggregation ratio decreased. Thus, it is expected that the loss of the copper wire could be reducedif when the copper thin wire is treated with ball milling by the aggregation of copper thin wires.

Treatment of Dyeing Wastewater Using Polyamid Ro-Membranes After the Pretreatment with Chemical Coagulants (화학응집제에 의한 전처리 후 폴리아미드 RO-분리막에 의한 염색폐수처리)

  • Jegal Jonggeon;Mo Joonghwan;Hwang Jeong-Eun;Lee Kew-Ho;Kim Jaephil
    • Membrane Journal
    • /
    • v.14 no.3
    • /
    • pp.230-239
    • /
    • 2004
  • Treatment of a dyeing wastewater was carried out using polyamide RO-membranes. Before applying the wastewater to the membrane process, it was pretreated with various chemical coagulants such as alum, ferric chloride and HOC-100A. In order to see the effect of the pretreatment on the membrane separation process, the optimum conditions for the coagulation and sedimentation process were sought. As a result, by the pretreatment, for all the coagulants used, the chemical oxygen demand (COD) and UV-absorbance of the wastewater were lowered by more than 70%. The pretreated wastewater was then applied to the membrane process. The effect of the coagulants used for the pretreatment on the membrane fouling was studied. From this study, it was found that the HOC-100A was the best out of the coagulants used for the removal of the materials that could cause membrane fouling.

High-Performance computing and future of materials simulation (고성능 컴퓨팅 환경과 대규모 재료 시뮬레이션의 미래)

  • Choe, Deok-Gi
    • Journal of Scientific & Technological Knowledge Infrastructure
    • /
    • s.8
    • /
    • pp.26-35
    • /
    • 2002
  • 초기 컴퓨터는 주로 원자핵물리와 관련된 계산에 사용되었으나 곧바로 컴퓨터의 도움을 받아 물리 문제를 해결하고자 하는 방법은 물리 전 분야에서 광범위하게 적용되었다. 물질의 가장 작은 요소를 찾고자하는 소립자물리학에서부터, 물질의 성질을 규명하는 응집물질물리, 나아가서 거대 우주의 구조를 밝히고자 하는 우주론에 이르기까지 컴퓨터의 사용이 확장되고 있다.

  • PDF