• Title/Summary/Keyword: 전위계

Search Result 220, Processing Time 0.024 seconds

The Study on the Corrosion Behavior of STS 304 for Gas Boiler in the Condensed Water (응축수 중에서 가스보일러용 STS 304의 부식거동에 관한 연구)

  • Du Yun Byoung;Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.9 no.1 s.26
    • /
    • pp.21-25
    • /
    • 2005
  • This paper was studied on the corrosion behavior of STS 304 for gas boiler in the condensed water, the electrochemical polarization test of STS 304 for gas boiler in the condensed water was carried out. And the corrosion behavior of STS 304 was considered. The main results are as following: 1) As corrosion environment is acidified from neutrality, the polarization resistance of STS 304 decreases and the corrosion potential is less noble. 2) The corrosion reaction mechanism of STS 304 is cathodic control. 3) As corrosion environment is acidified, the passive potential range of STS 304 decreases. Also, the passive current density of STS 304 increases.

  • PDF

Change in Magnetic Flux in the Air Due to Load (하중에 의한 공기중 자속의 변화)

  • Lee, Jeong-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.1
    • /
    • pp.21-26
    • /
    • 2009
  • In order to determine the effective way of measuring the Mode I stress intensity factor($K_1$) by means of the alternating current potential drop(ACPD) technique for a material containing a two-dimensional surface crack, the change in magnetic flux in the air due to load was studied theoretically and experimentally. The magnetic flux in the air between crack surfaces is uniform and is not changed by increasing the load in the specimen and experimental results are the same as those obtained from theoretical analysis. Therefore, the change in potential drop due to load in the measuring system which was designed to induce a large amount of electro-motive force was caused by the change in internal inductance of material and the change in the mutual inductance concerned with internal inductance of material.

Non-Pt transition metal electrode catalyst for Oxygen Reuction Reaction of Polymer Electrolyte Membrane Fuel Cell (고분자 전해질 연료전지의 산소환원반응을 위한 비백금계 전이금속 전극 촉매)

  • Kim, Jy-Yeon;Lee, Sang-Beom;Park, Kyung-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.383-385
    • /
    • 2009
  • 비백금계 코발트 전이금속 촉매를 탄소지지체에 담지한 뒤, 암모니아 분위기에서 $500^{\circ}C$에서 3시간 동안 열처리하는 과정을 통해 코발트 질화물 촉매를 제조했다. 제조된 촉매들의 구조와 형태를 각각 XRD, HE-TEM등을 통해 분석하였고, 전위 측정기를 이용한 CV, LSV 결과로부터 촉매의 전기화학적 산소 환원특성을 분석하여, 기존의 연료전지 양극 촉매로 사용되는 고가의 백금촉매를 대체하기 위한 비백금계로서의 가능성을 확인하였다.

  • PDF

Evaluation of Internal Stress and Dislocation Velocity in Creep with Austenite Stainless Steels (오스테나이트계 스테인리스강의 크리프 변형중 내부응력과 운동전위밀도의 평가)

  • Kim Hyun Soo;Nam Ki Woo;Park In Duck
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.214-219
    • /
    • 2005
  • To investigate the change of internal stress and mobile dislocation density in the creep, stress relaxation test was examined from each strain range. Mobile dislocation density increased until it reached minimum creep rate but after that, it decreased. Internal stress did not change until it reached minimum creep rate but after that, it decreased. The stress relaxation rate is fast and approached zero later 1.5 seconds, which were begun in the stress relaxation. When the applied stress is large, the internal stress is large. It is cleared that dislocations glide viscously which N passes by cutting Cr atom rather than typical viscosity movement by the evaluation of mobility of dislocation in STS310J1TB.

A Study on the IR Drop in Crevice of AISI 304 Stainless Steel by Temperature Variation (온도변화에 따른 AISI 304SS의 틈내 전위강하에 관한 연구)

  • 나은영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.872-878
    • /
    • 2003
  • As the results of recent industrial development, many industrial plants and marine structures are exposed to severe corrosion environment than before. Especially, under the wet environment, crevice corrosion damage problems necessarily occur and encourage many interests to prevent them. In this study, the electrochemical polarization test was carried out to study characteristics of crevice corrosion for AISI 304 stainless steel in various solution temperatures. The results are as follows ; 1) as the solution temperature increased in IN $\textrm{H}_2\textrm{SO}_4$, the passive current density and critical current density were increased, whereas corrosion potential and break down potential were nearly constant, 2) as the solution temperature increased. the induced time for initiation of crevice corrosion was shortened. 3) The potential range in the crevice was -220mV/SCE to -380mV/SCE according to the distance from the crevice opening, which is lower than that of external surface of -200mV/SCE.

Cochlear Implant of the Hair-Cell Damaged Cats (모세포 손상 가묘에 대한 Cochlear Implant)

  • 장인원;김성남;양한모;최윤호;조용범
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.9.1-10
    • /
    • 1978
  • Recently the authors have observed various wave-forms by insertion of induction coil into the scala tympani as well as attached outer device in the outside of the body in damaged hair cells of the cats. In the cochlear nerve. action potential indicated different polarities induced by examination of the bundle of the cochlear nerve fibers. Impulse wave-form as a result of excitation of cohlear nerve fibers showed bipolar wave-form such as negative 1 and positive 1. Therefore action potential showed also bipolar wave-form as above mentioned. We can obtained suitable response with above mentioned outer and inner device as an exact oscillogram.

  • PDF

교류계도반

  • 김정진
    • 전기의세계
    • /
    • v.9
    • /
    • pp.46-50
    • /
    • 1962
  • 전력계통의 운영에 있어서 예컨데 손실전력의 감소라든가 안정한 운전의 검토 또는 전력계통의 계획시에 있어서 경제적인 송전선 및 변전소의 건설지점개정, 송전망구성방법, 고장시의 대책등을 결정하는데 있어서는 이에 관한 각종 계산을 할 필요가 생기게 된다. 그러나 복잡한 전력계통에 있어서 이들 문제를 사람이 직접 계산 해결한다는 것은 용이한 일이 아니며 필요로하는 많은 시일과 노력 및 이에 대한 그 결과의 부적확등으로 모든 문제를 다 계산하여 해결한다는 것은 바랄 수 없었다. 이와같은 전력계통의 계산을 단시간에 또한 정확하게 가능하도록 한 것이 교류계산반이다. 교류계산반은 다수의 막정발전기, 가변저항, 가변 Inductance, 가변 capacitance, 변압기등의 전위를 비치하고 이들 전위를 연결하여 실제전력계통과 같은 모위회로를 만들고 각부의 전압, 전류, 전력, 위상각등의 제량을 측정함으로써 실계통의 제특성을 신속히 파악 분석하게 한 것으로서 계산기의 분류중에서는 Analogue형의 직접형에 속하며 특히 이 교류계산반은 직접상이형인 계산장치이다.

  • PDF

GSMBE 방법으로 Si(110) 기판 위에 성장된 GaN 박막의 미세구조 연구

  • Lee, Jong-Hun;Kim, Yeong-Heon;An, Sang-Jeong;No, Yeong-Gyun;O, Jae-Eung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.193.1-193.1
    • /
    • 2015
  • 실리콘 (Si) 기판 위에 고품질의 갈륨질화물 (GaN) 박막을 성장시키기 위한 노력이 계속되고 있다. 실리콘 기판은 사파이어 기판 보다 경제적인 측면에서 유리하고, 실리콘 직접화 공정에 GaN 소자를 쉽게 접목 가능하다는 장점이 있다. GaN 박막은 2차원 전자 가스형성을 통한 고속소자, 직접 천이형 밴드갭을 이용한 발광소자 및 고전압 소자로써 활용 가능한 물질이다. 종래에는 Si(100) 및 Si(111) 기판 위에 GaN 박막 성장에 대한 연구가 주로 진행되었다. 하지만 대칭성과 격자 불일치도 등 결정학적 특성을 고려할 때 Si(100) 기판 위에 고품질의 GaN 박막을 성장시키는 것은 쉽지 않다. Si(111) 기판은 실리콘 소자 직접화 공정에 적합하지 못한 단점을 가지고 있다. 반면, 최근 Si(110) 기판 위에서 비등방적 변형 제어를 통한 고품질 GaN 박막 성장이 보고 되어 실리콘 집적 소자와 결합한 고전압 소자 및 고속소자 구현에 관한 연구가 진행되고 있다. 본 연구에서는 투과전자현미경 연구를 바탕으로 Si(110) 기판 위에 성장된 GaN의 미세구조에 관한 연구를 소개한다. 열팽창계수의 차이에 의한 GaN 박막 내 결함 생성을 줄이기 위하여 AlN 완충층이 사용되었다. GaN 박막을 암모니아 ($NH_3$) 유량이 다른 조건에서 성장시킴으로써 GaN 박막 미세구조의 암모니아 유량 의존성에 관한 연구를 진행하였다. GaN 박막에서 투과전자현미경 연구와 X-ray 회절 연구를 통하여 결함 거동 및 결정성을 확인하였다. $NH_3$ 유랑이 증가함에 따라 GaN의 성장 거동이 3차원에서 2차원으로 변화됨을 관찰하였다. 또한, 전위밀도의 증가도 확인되었다. $NH_3$ 유량이 낮은 경우 GaN 전위는 AlN와 GaN 경계에 주로 위치하고 GaN 표면 근처에는 전위밀도가 감소하였으나, $NH_3$ 유량이 높을 경우 GaN 박막 표면까지 전위가 관통됨을 확인하였다.

  • PDF

The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids ($LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향)

  • Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.33-39
    • /
    • 2001
  • This paper was studied on corrosion behavior of absorption refrigeration systems using $LiBr-H_2O$ working fluids. In the various concentration of lithium bromide solution, polarization test of SS 400, Cu(C1220T-OL) and Al-Ni bronze is carried out. And the corrosion behavior of materials forming absorption refrigeration systems is investigated. The main results are as following: 1) As concentration of lithium bromide solution increases, polarization resistance of materials of each kinds is low. And open circuit potential becomes less noble, the corrosion current density is high drained 2) Open circuit potential of SS 400 is less noble than that of Cu and Al-Ni bronze, corrosion current density of SS5 400 is high drained than that of Cu and Al-Ni bronze. 3) Anodic polarization of Cu and Al-Ni bronze in $62\%$ LiBr solution continues the active state. that of Cu and Al-Ni bronze in the natural sea water maintains the active state and the critical current for passivation appears.

  • PDF

Development of Pains Therapy System Using Focused Variable Electromagnet (비침습 집중형 전자기장을 이용한 통증치료기 개발)

  • Cho, Dong-Guk;Lee, Gyoun-Jung;Kim, Soo-Byung;Kwon, Sun-Min;Shin, Tae-Min;Lee, Kyoung-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1157-1166
    • /
    • 2009
  • The effect of acupuncture that occurs at Meridians, can not be defined by western science. But we can find out the electrical effects when acupuncturing by measuring the charges meridians electric potential. So instead of using a needle to acupuncture, we used a electromagnet to give the same effect. We stimulated the meridians, with a electromagnet. Then we observed the pattern of the meridians potential, that occurred at ST-39 and ST-37. After doing clinical experiments with the acupuncture stimulation and the electromagnet stimulation. We found out the acupuncture stimulation and the electromagnet stimulations electric waves were similar. From this result, we knew it was possible to give similar effects to acupuncture stimulation by using electromagnets.