• Title/Summary/Keyword: 전원부하

Search Result 767, Processing Time 0.032 seconds

Design and Verification of Electrical System for Unmanned Aerial Vehicle through Electrical Load Power Analysis (전원부하분석을 통한 무인항공기 전기시스템 설계 및 검증)

  • Woo, Heechae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.675-683
    • /
    • 2018
  • In this paper, we have proposed a design and verification methods of electrical system and power loads for unmaned aeriel vehicles(UAVs) through electrical load analysis. In order to meet a UAV system requirement and electrical system specifications, we have designed an electrical power system for efficient power supply and distribution and have theoretically analyzed the power loads according to the power consumption and power bus design of UAV. Using electrical system rig, the designed electrical power system has been experimentally verified. Also, we have performed several flight tests to verify the UAV electrical system and power loads. It is concluded that the proposed design and verification method of electrical system for UAV system.

The influence on Harmonic and power factor with power source connected power conversion unit (전력변환장치 연계에 마른 계통전원에 고조파 및 역률이 미치는 영향)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.33-36
    • /
    • 2008
  • 전기철도에서 사용되는 전원은 한전 계통을 통해 유입되고 별도의 전원 계통을 구축하여 운영한다. 따라서 한전 계통과의 인터페이스에 따른 국내외 기준을 만족하여 진기철도 계통전원 시스템을 구축하여야 한다. 본 논문에서는 철도차량 사업소 구축시 중수선, 종합 관리동등의 부하특성에 따른 부하역률 변화 및 전력변환장치를 연계되었을 때 계통전원에 미치는 고조파 영항을 연구하였다. 시뮬레이션을 통해 철도차량 사업소내의 계통전원이 국내외 기준에 적합할 수 있도록 제시하였다.

  • PDF

Operational Characteristic Analysis of DC Micro-grid with Detail Model of Distributed Generation (분산전원 세부모델을 적용한 DC Micro-grid의 동작특성 분석)

  • Lee, Ji-Heon;Kwon, Ki-Hyun;Lee, Hye-Yeon;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10c
    • /
    • pp.151-153
    • /
    • 2008
  • DC 마이크로그리드는 태양광과 연료전지와 같은 DC 출력의 분산전원, 풍력이나 가스엔진과 같은 AC 출력의 분산전원이 이차전지나 수퍼커패시터와 같은 에너지 저장장치와 직류로 결합되어 있는 구조로, 최근 급증하고 있는 디지털부하에 고품질, 고신뢰도 전력을 공급하는 새로운 직류배전시스템이다. 본 연구에서는, 먼저 DC 마이크로그리드의 한 시스템 구성을 가정하고, 이들 분산전원과 에너지저장의 컨버터를 제어하는 기법을 제안하였다. 또한 PSCAD/EMTDC 소프트웨어를 사용하여 각각의 분산전원의 세부모델을 구현하고, 이를 DC 마이크로그리드로 구성한 후 분산전원의 생산량, 에너지저장의 저장량, 부하의 소모량, 연계 계통의 공급량을 타당한 시나리오로 가정하여 전체 마이크로그리드의 동작을 분석하였다.

  • PDF

Planning for Operation of Dispersed Generation Systems considering Load Unbalance in Distribution Systems (배전계통에서 부하불평형을 고려한 분산형 전원의 운영 계획)

  • 이유정;유석구
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.5
    • /
    • pp.118-125
    • /
    • 2003
  • This paper presents a scheme for the placement of dispersed generator systems(DGs) based on load model in unbalanced systems. Groups of each individual load model consist of residential, industrial, commercial, official and agricultural load The main idea of solving fuzzy goal programming is to transform the original objective function and constraints into the equivalent multi-objectives functions with fuzzy sets to evaluate their imprecise nature for the criterion of power loss minimization, the number or total capacity of DGs and the bus voltage deviation, and then solve the problem using genetic algorithm The method proposed is applied to IEEE 13 bus unbalanced distribution systems to demonstrate its effectiveness.

For the multiple-output switching mode power supply implementation standby mode using the controller of secondary linear regulator (선형 레귤레이터 제어기의 부하전류 정보를 이용한 다중출력 전원공급장치에서의 대기전력 저감회로 구현)

  • Lee, Jong-Hyun;Jung, An-Yeol;Park, Joung-Hu
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.514-515
    • /
    • 2010
  • 본 논문은 다중출력 스위칭 모드 전원 공급장치의 경부하 상태에서 2차측의 부하 전압안정을 위하여 일반적으로 사용하는 선형 전압조정기의 제어기 내 부하전류정보를 이용하여, 대기모드를 구현함으로써 시스템의 효율을 향상 시켰다. 제안된 회로의 동작원리를 설명하고 이를 시뮬레이션을 통하여 확인하고 20W급 하드웨어 프로토타입을 이용하여 검증하였다.

  • PDF

Characteristic PCS of Inverter by Boost Converter of PV Generation (태양광 발전 부스트 컨버터를 이용한 인버터 PCS 특성)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Oh, Sang-hak
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.6
    • /
    • pp.654-664
    • /
    • 2018
  • In this paper, this system is operated by PCS that is driven by being synchronized voltage fed inverter and AC source, and in the steady state of power source charge battery connected to DC side with solar cell using a photovoltaic (PV) that it was so called constant voltage charge. it can cause the effect of energy saving of electric power, from 10 to 20%. and through a normal operation of electric energy storage system (EESS). In addition, better output waveform was generated because of pulse width modulation (PWM) method, and it was Proved to test by experiment maintained constant output voltage regardless of AC source disconnection, load variation, and voltage variation of AC power source.

An Electronic Step-Down Transformer with Voltage Stabilization Characteristics for Custom Power (전압 안정화 특성을 갖는 수용가용 전자식 강압형 변압기)

  • 최남섭;강정식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.423-426
    • /
    • 2001
  • In this paper, an electronic step-down transformer with output voltage stabilization characteristics is presented. The proposed electronic transformer has some advantages and features as follows: 1) It has 40 % weights lighter than that of commercial magnetic transformer, 2) It has output voltage stabilization characteristic with regulated output voltage over input variations, 3) It cab be operated as circuit breaker in the case of emergency, 4) It can be operated with so called soft starting function. Moreover, the electronic transformer may have stand-by power cutoff function and act as distortion compensator. This paper show the circuit diagram and present its features through various PSPICE simulations.

  • PDF

The Study of Module Type 20kW Plasma Power Supply for Magnetron Sputter (마그네트론 스퍼터용 모듈형 20kW 플라즈마 전원장치에 대한 연구)

  • Han Hee-Min;Seo Kwang-Duk;Cho Yong-Kyu;Kim Joohn-Sheok
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.56-58
    • /
    • 2006
  • 본 논문은 PVD(Physical Vapor Deposition)의 마그네트론 스퍼터(Magnetron sputter) 박막코팅(Thin film coating) 공정에서 플라즈마(Plasma)를 발생시키고 제어하는 DC 전원공급 장치에 관한 것이다. 이 논문에서는 임피던스의 변화가 심하고 아크(Arc)가 빈번히 발생하는 플라즈마 부하의 특성에 대해, 과도상태(Transient state)의 출력제어 성능을 향상시키고 아크 발생 시 부하로 전가되는 아크에너지를 저감시키기 위한 직류 전원 공급 장치에 대해 소개한다. 전원장치는 수하특성을 가지며 플라즈마 부하에 적합한 출력 제어성을 확보하고 아크 에너지를 최소화하기 위해 고주파 L-C 직렬공진회로 기법을 적용한다. 개발된 DC 20kW급 전원 장치는 인버터와 고주파 절연변압기, 정류기로 구성된다. 인버터는 $100{\sim}200kHz$의 제어주파수로 PFM 및 PWM 제어를 하며, 단위용량 5kW급 컨버터 4개를 직, 병렬 연결하여 출력리플을 최소화 하였다. 개발된 장치의 우수한 제어성능은 실제 플라즈마 공정에서 시험 평가한 결과를 통해 검증할 수 있었다.

  • PDF

A Multifunctional Three-Phase Electronic Step-Down Transformer with Constant Output Voltage Characteristics (정전압 출력 특성을 갖는 다기능 3상 전자식 강압형 변압기)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.309-313
    • /
    • 2001
  • In this paper, a multifunctional three-phase electronic step-down transformer with output voltage stabilization characteristics is presented for custom power applications. The proposed electronic transformer has some advantages and features as follows: 1) It has 40 % weights lighter than that of commercial magnetic transformer, 2) It has output voltage stabilization characteristic with regulated output voltage over input variations, 3) It cab be operated as circuit breaker in the case of emergency, 4) It can be operated with so called soft starting function. Moreover, the electronic transformer may have stand-by power cutoff function and act as distortion compensator. This paper show the circuit diagram and present its features through various PSPICE simulations.

  • PDF

A Study on the Implementation and Modeling of 20kW Scale ESS Load Test Device for Emergency Generator (소방용 비상발전기의 현장부하시험을 위한 20 kW급 ESS 부하시험장치 모델링과 구현에 관한 연구)

  • Choi, Seung-Kyou;Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.541-550
    • /
    • 2019
  • An emergency generator is key equipment for fire-fighting to supply power to fire-fighting facilities, which protect property and people in cases of fire accidents. A rated load test for emergency generators must be carried out by connecting an emergency load to the generator in accordance with related regulations. However, a no-load test has been performed for emergency generators in general since serious problems can occur when the main power is cut off, including the damage of customer devices and shut down of critical loads. Therefore, this paper proposes a load test method for an emergency generator using energy storage system (ESS) without the interruption of main power. The emergency power system was also modeled based on PSCAD/EMTDC software, and a 200-kW scale ESS load test device was implemented. The simulation and test results show that the load test method is useful and practical for an emergency power supply system.