• 제목/요약/키워드: 전열특성

Search Result 337, Processing Time 0.029 seconds

Heat Transfer of a Two-Dimensional Jet Impinging on the Wall with Transverse Repeated Ribs of Square Cross-Section (四角리브를 갖는 傳熱面에 衝突하는 2次元 噴流의 熱傳達에 관한 硏究)

  • 김상필;서정윤
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.214-221
    • /
    • 1987
  • The purpose of this study is augmentation of heat transfer without additional power in the case of rectangular air jet which impinges vertically on the heating surface. The experimental results are obtained heat transfer augmentation of a two-dimensional impinging jet using the surface roughness of transverse repeated-rib type. The integral average heat transfer coefficient of ribbed plate is about two times larger than that of flat plate. In order to supplement the information about the mechanism of heat transfer augmentation, the flow structure in the stagnation region is visually studied by using the smoke wire technique. The heat transfer augmentation is due to the effect of stretching of large scale vortex in the stagnation region.

Evaluation of Eddy Current Signals from the Inner Wall Axial Cracks of Steam Generator Tubes (증기발생기 전열관의 내면 축방향 균열에 대한 ECT 특성 평가)

  • Choi, Myung-Sik;Hur, Do-Haeng;Lee, Doek-Hyun;Park, Jung-Am;Han, Jung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.501-509
    • /
    • 2001
  • For the enhancement of ECT reliability on the primary water stress corrosion cracks of nuclear steam generator tubes, of which the occurrence is on the increase, it is important to comprehend the signal characteristics on crack morphology and to select an appropriate probe type. In this paper, the sizing accuracy and the detectability for the inner wall axial cracks of tubes were quantitatively evaluated using the following specimens: the electric discharge machined notches and the corrosion cracks which were developed on the operating steam generator tubes. The difference of eddy current signal characteristics between pancake and axial coil were also Investigated. The results obtained from this study provide a useful information for more precise evaluation on the inner wall axial tracks oi stram generator tubes.

  • PDF

질소 이온빔을 이용한 인코넬690의 기계적 특성 변화 연구

  • 홍인석;황용석
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05b
    • /
    • pp.118-122
    • /
    • 1997
  • 차세대 원자력발전소 증기발생기 전열관 재료로 채택된 니켈기저합금으로 기존 전열관 재료인 인코넬600에 비해 고온 고압 조건에서 응력부식균열에 강한 장점을 가진 합금인 인코넬690 시료에 최대 에너지 120 keV의 질소 이온빔을 조사하여 이 재료의 기계적 특성 변화를 관측하였다. 특성 시험으로는 표면 경화를 관찰하기 위한 미세 경도 시험을 수행하여 미세 경도 증가를 확인하였다 아울러 표면 경화가 피로 특성에 미치는 영향을 관찰하기 위해 피로 균열 전파 시험을 수행하여 이온 주입으로 인한 표면 경화가 피로 균열 전파를 촉진시킴을 관찰하였다.

  • PDF

The Power Spectral Density Characteristics of Lift and Drag Fluctuation on a Heat Exchanger Circular Tube (열교환 단일 원관의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.4
    • /
    • pp.35-40
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. The present study examined the results of the previous experimental researches for the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared from the present CFD analysis. For the previous mentioned purpose, the present CFD analysis introduced a single circular cylinder and calculated with the unsteady laminar flow over the cylinder. The characteristics of vortex shedding and lift and drag fluctuation over the cylinder was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift and drag PSD over a single circular cylinder was established from the present CFD study.

2상 밀폐 열사이폰 루프의 전열특성 및 안정성에 관한 연구

  • 이진호;김태열;설신수;이병일
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.4
    • /
    • pp.971-980
    • /
    • 1990
  • 본 연구에서는 실험적으로 2상 밀폐 직사각형 열사이폰 루프에 대하여 안정성 에 주된 영향을 줄수 있는 변수들, 즉 루프 경사각도, 작동유체의 유동현상을 관찰하 고 작동유체의 온도변동과 류프의 전열성능을 측정하여 열사이폰이 안정하게 작동하는 범위를 종합적으로 조사해 보았다.

Condensing heat transfer characteristics of alternative refrigerants in small diameter tubes (세관내 대체냉매의 응축 열전달 특성)

  • 오후규;홍진우
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.28 no.5
    • /
    • pp.396-402
    • /
    • 1999
  • 1980년대부터 본격적으로 제기된 대기 환경 오염 문제로 인해서 CFCs 및 HCFCs계 냉매에 대한 대체 연구가 활발히 진행되었는데, 이와 관련한 열교환기의 고성능화, 콤팩트화 등에 관한 연구도 광범위하게 이루어지고 있다. 이중에서 특기할만 한 것은 종래의 전열관보다 관경이 대단히 적은 세관을 적용하는 경우가 있으며, 그 적응 범위도 점점 더 넓어질 전망이다. 이것은 유효전열 면적의 극대화, 난류효과의 상승, 가공성기 향상, 유연성 등 세관만이 가질 수 있는 여러 가지 전열 성능상의 장점 때문이라 생각한다.

  • PDF

A study on the flow induced vibration on a heat exchanger circular cylinder (열교환 단일 원관의 유동 유발 진동 특성에 관한 연구)

  • Ha, Ji Soo;Lee, Boo Youn;Shim, Sung Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.109-114
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. The present study examined the results of the previous experimental researches for the nondimensional PSD characteristics by CFD analysis and the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared from the present CFD analysis. For the previous mentioned purpose, the present CFD analysis introduced a single circular cylinder and calculated with the unsteady laminar flow over the cylinder. The characteristics of vortex shedding and lift fluctuation over the cylinder was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift PSD over a single circular cylinder was established from the present CFD study.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

A Study on the Characteristics of Lift Fluctuation Power Spectral Density on a Fin Tube in the Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력 변동 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn;Shim, Sung Hun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.211-216
    • /
    • 2015
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift fluctuation over the fin tube was investigated. The derived nondimensional PSD was compared with the results of the previous experimental researches and the characteristics of lift PSD over a single fin tube was established from the present CFD study.

Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery (폐용제 회수용 이중관형 열교환기 특성 해석)

  • 구재현;이재근
    • Resources Recycling
    • /
    • v.9 no.3
    • /
    • pp.13-21
    • /
    • 2000
  • This study describes to analyze the heat transfer characteristics of waste solvent recovery system using a double pipe heat exchanger heating solvent by the hot oil. The solvent recovery system consists of the feeding pump, the double pipe heat exchanger, the vacuum spray chamber, and the condenser. A double pipe heat exchanger consists of the first section to conduct the heating of solvent to the thermal saturated point and the second section to evaporate the saturated solvent. The heat transfer area for vaporization of water, benzene and alkylbenzene was predicted by the heat balance modelling and experimentally measured from the temperature distribution as a function of solvent flow rate and heating temperature. The required heat transfer area for vaporization was increased with increasing solvent flow rates and with decreasing heating temperatures due to decreased quantity of transferred heat per the unit area. Theoretical modelling of the heat transfer area for solvents vaporization in the pipe showed good agreement with experimental results. Results showed to be suitable for the waste solvent recovery using a double pipe heat exchanger.

  • PDF