• Title/Summary/Keyword: 전열면

Search Result 77, Processing Time 0.023 seconds

Small Scale Modelling Experiments for Evaluating Lateral Resistance of Block-Type Breakwater I : Complex Blocks with Group Piles (블록식 방파제의 수평저항력 평가를 위한 실내모형실험 I : 무리말뚝으로 보강된 복합 블록의 거동)

  • Kang, Gichun;Kim, Jiseong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.95-103
    • /
    • 2021
  • While the existing pile foundation had the role of supporting the superstructure or reducing the earth pressure, recently there are cases where it is integrated with the superstructure to increase the lateral resistance. This study aims to evaluate a lateral resistance of block-type breakwaters with group piles by modelling experiments. The lateral resistance and bending moments of the piles by penetrated depths for the piles were measured. As a result, it was found that the lateral resistance increased as the depth of embedment of the group piles. In particular, the lateral resistance was 1.52 times greater in the case where the pile embedded up to the riprap layer than the case where the pile was embedded into the block. For the bending moment, the rear piles ware larger than the front piles, and the outside piles were larger than the inside piles. The location of the maximum bending moment in the ground was shown at the interface between the riprap layer and the natural ground.

Heat Penetration of Canned Oyster Mushroom (느타리버섯 통조림의 전열특성)

  • Lee, Dong-Sun;Park, Noh-Hyeon;Shin, Dong-Hwa;Min, Byong-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.206-210
    • /
    • 1984
  • Heat penetration pattern of canned oyster mushroom(Pleurotus astreatus) was monitored for processing variables-can size, heating temperature and solid fill fraction, and its effects on sterilization condition was reviewed. The $f_h$ value decreased sharply with decrease of solid fill fraction and then became stable from certain solid fill fraction unique to can size. Heat penetration was a little faster at higher heating temperature with lower $f_h$ value. As viewed from $f_h$ value, convection started at higher solid fill fraction with higher length/diameter ratio, and $f_h$ values decreased to about 1.0 with decrease of solid fill fraction. From standpoint of overall cost, retorting time and energy consumption, solid fill fraction of 3/5 was optimum for all can sizes considered.

  • PDF

Study on the Storage of Chestnut (밤 저장(貯藏)에 관(關)한 연구(硏究))

  • Yim, Ho;Kim, Choung-Ok;Shin, Dang-Wha;Suh, Kee- Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.170-175
    • /
    • 1980
  • A mass production of chestnut necessiates the development of economic long-term storage method. The main objective of this study was to confirm the technical aspect of the chestnut storage method which was developed by two year project and to review the method of commercial application. The chestnut used for the experiments were separated in brine $(5.5{\sim}6.0^{\circ}\:B{\acute{a}}ume)$ into matured and unmatured lots and fumigated with $CS_2$ at a 5 $lb/27\;m^3$ level for $25{\sim}30\;hrs.$ The chestnuts were packed in wooden boxes with sawdust (50% moisture) in the ratio of 1 : 1 by volume. The boxes were stored in the cold room $(1{\pm}1^{\circ}C,\;85{\sim}95%\;RH)$ and the cellar ($0{\sim}10^{\circ}C$, controlled only by circulating night cool air). The results obtained were as follows: 1. Fully matured chestnut could be successfully preserved $8{\sim}9\;months$ at a l0% decay level in the cold room and $4{\sim}5\;months$ months in cellar. 2. Immatured chestnuts wire inferior to the matured in storage stability. At the maximum storage period, its storage life was two months shorter. 3. The heat transfer equation of piled chestnuts with sawdust can be suggested as $T_{\infty}-T_0=(T_{\infty}-T_0){\cdot}10^{-t/320}$ and j and $f_h$ values were 1 and 320 min, respectively. 4. The chestnuts in the package of storage unit had longer shelf life than naked chestnut during the retail distribution at ambient temperature.

  • PDF

Analysis of the Insulation Effectiveness of the Thermal Insulator by the Installation Methods (보온단열재의 설치방법에 따른 보온성 효과 분석)

  • Kim, Young-Bok;Lee, Si-Young;Jeong, Byoung-Ryong
    • Journal of Bio-Environment Control
    • /
    • v.18 no.4
    • /
    • pp.332-340
    • /
    • 2009
  • In this study, the thermal insulation effectiveness of the greenhouse insulators by the installation methods was investigated to find the right installation way of the insulation materials. Physical properties of the insulators such as thickness, air transmissivity, apparent density, ultraviolet rays cutoff ratio, reflectance, thermal conductivity, moisture absorptivity were evaluated and the insulation ability of the insulators were measured by the module experiments. For the same insulator, the insulation ability of the case with the outward direction of the black colored face, i.e., with the inward direction of the white colored face, was better than that of vice versa. The case of the black colored both surfaces was better than the case of the white colored both surfaces. For aluminium reflection material, the case with the outward direction of the lustre face, i.e., with the inward direction of the non-lustre face, was better than that of vice versa. For the same material with the inner thin polyethylene foam (or polyester) and the chemical wool, the case with the outward direction of the inner thin polyethylene foam (or polyester), i.e., with the inward chemical wool, was better than that of vice versa. Addition of the inner thin polyethylene foam increased the insulation effect very much.

Potential of HAZ Property Improvement through Control of Grain Boundary Character in a Wrought Ni-based Superalloy (단련용 Ni기 초내열합금의 입계구조 제어를 통한 HAZ 특성 향상 가능성 고찰)

  • Hong, H.U.;Kim, I.S.;Choi, B.G.;Jeong, H.W.;Yoo, Y.S.;Jo, C.Y.
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.43-43
    • /
    • 2009
  • 단련용 다결정 Ni기 초내열합금은 우수한 가공성, 내산화성, 고온특성 등으로 가스터빈 연소기, 디스크, 증기발생기 전열관 등 발전용 고온부품 소재에 널리 적용되고 있다. 최근 발전설비의 고효율화를 꾀하기 위해 작동 온도를 현격히 증가시키는 기술방향으로 발전하고 있고, 소재측면에서는 기존의 초내열합금 대비 고기능성을 확보할 수 있는 차세대 Ni기 초내열합금 개발이 유럽, 미국, 일본, 중국 등을 중심으로 활발히 이루어지고 있다. 이러한 소재의 고온강도 (온도수용성)를 향상시키기 위해서는 통상 규칙격자 금속간화합물인 $Ni_3(Al,Ti)-{\gamma}'$상의 분율을 증가시킬 수 있지만, ${\gamma}'$상분율이 증가할 경우 용접 및 후열처리 동안 용접열영향부 (HAZ)에서 액화균열이 발생할 가능성이 높아진다. 결정립계를 따라 발생하는 HAZ 액화균열은 입계특성에 의해 크게 영향을 받을 것으로 판단된다. 한편, 본 연구자들은 최근 입계 serration 현상을 단련용 합금에 도입시키는 특별한 열처리를 이론적 접근법을 통해 개발하였다. 형성된 파형입계는 결정학적인 관점에서 조밀 {111} 입계면을 갖도록 분해 (dissociation)되어 낮은 계면에너지를 갖게 됨을 확인하였으며, 입계형상 변화뿐만 아니라 탄화물 특성변화까지 유도하여 크리프 수명을 기존대비 약 40% 정도 향상시킴을 확인하였다. 이러한 직선형 입계 대비 'special boundary'로 간주되는 파형입계가 도입될 경우, HAZ 결정립크기 변화 및 액화거동에 미치는 영향을 고찰하고, 아울러 입계특성 제어가 용접성/용접부 품질 향상에 기여할 수 있는 가능성도 토의하고자 하였다. 본 연구에서는 재현 HAZ 열사이클 시험을 통해 미세구조를 정량적으로 비교하였다. 상대적으로 입계구조가 안정된 파형입계의 이동속도가 高계면 에너지를 갖는 직선형 입계보다 느려 HAZ 결정립 성장이 효과적으로 억제됨을 확인할 수 있었다. 입계 액화거동을 살펴보면, 두 시편 모두 $M_{23}C_6$, MC 등 입계탄화물 계면이 빠른 승온중 액화반응 (constitutional liquation)에 의해 입계가 액화되었으며, 이후 급냉에 의해 입계에 액상막이 존재한 흔적이 발견되었다. 최고온도별로 입계액화 폭/비율을 정량적으로 비교한 결과, 파형입계가 직선입계 대비 대체로 낮음을 확인할 수 있었으며, 때때로 액화되지 않고 잔존하는 입계 탄화물이 관찰되었다. 재현 HAZ 미세조직을 통해 Hot ductility 시험 결과를 유추하자면, 파형입계가 직선입계 보다 좁은 취성온도영역 (Brittle Temperature Range)을 나타낼 것으로 예상되어, 입계특성제어에 의해 Ni기 초내열합금의 용접성을 향상 가능성을 확인하였다.

  • PDF

A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler (870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰)

  • Woo, Gwang-Yoon;Kim, Soo-Seok;Park, In-Chan;Ham, Young-Jun;Lee, Eung-Yoon
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • In this study, the boiler efficiency and the change of boiler combustion state with the burner operation of the uppermost layer of 870MW opposite fired coal boiler were measured. Test results showed that the boiler efficiency was high in the order of the uppermost layer simultaneous operation of the front and rear burners, the front burner, and the rear burner operation. When the front and rear burners were operated simultaneously, the heat absorption rate of water walls in the boiler furnace was uniform at four side, and the temperature deviation of the left and right steam on the convection front surface decreased. As the heat absorption rate of the boiler improved, the loss of boiler exhaust gas decreased and the coal supply amount decreased by 8 tons/hour compared to the operation of the rear burner. This will contribute not only to the reduction of fuel cost but also to the reduction of greenhouse gas emissions.

  • PDF

Analysis of Heat Transfer Characteristics on Multi-layer Insulating Curtains Coated with Silica Aerogel (실리카 에어로겔이 흡착된 다겹보온커튼의 전열 특성 분석)

  • Jin, Byung-Ok;Kim, Hyung-Kweon;Ryou, Young-Sun;Lee, Tae-Seok;Kim, Young-Hwa;Oh, Sung-Sik;Kang, Geum-Choon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.3
    • /
    • pp.273-278
    • /
    • 2019
  • The multi-layer insulating curtains used in the experiment was produced in six combinations using non-woven fabric containing aerogel and compared and analyzed by measuring heat flux and heat perfusion rates due to weight, thickness and temperature changes. Using silica aerogel, which have recently been noted as new material insulation, this study tries to produce a new combination of multi-layer insulating curtains that can complement the shortcomings of the multi-layer insulating curtains currently in use and maintain and improve its warmth, and analyze the thermal properties. The heat flux means the amount of heat passing per unit time per unit area, and the higher the value, the more heat passing through the multi-layer insulating curtain, and it can be judged that the heat retention is low. The weight and thickness of multi-layer insulation curtains were found to be highly correlated with thermal insulation. In particular, insulation curtains combined with aerogel meltblown non-woven fabric had relatively higher thermal insulation than insulation curtains with the same number of insulation materials. However, the aerogel meltblown non-woven fabric is weak in light resistance and durability, and there is a problem that the production process and aerogel are scattering. In order to solve this problems, the combination of expanded aerogel non-woven fabric and hollow fiber non-woven fabric, which are relatively simple manufacturing processes and excellent warmth, are suitable for use in real farms.