• 제목/요약/키워드: 전열교환기

검색결과 39건 처리시간 0.031초

공동주택 전열교환기 필터종류 및 두께에 따른 미세먼지 제거율 평가 (Evaluation of Particulate Matter Removal Rate according to Filter Type and Thickness of Total Heat Exchanger in Apartment Houses)

  • 송용우
    • 토지주택연구
    • /
    • 제11권4호
    • /
    • pp.93-98
    • /
    • 2020
  • This study examined the particulate removal performance of three different types of air filters inside a heat exchanger. Of interest was the ability of each filter type in reducing the transmission of outdoor particulate matter of PM10 from entering an apartment while the heat exchanger was in operation. The study tested one commonly used medium filter (E11 grade) and two HEPA filters (H13 grade) of different thicknesses. Two different concentrations of particulate matter were used in the experiment to address different ambient air quality conditions in Korea, 32.75 ㎍/㎥ and 67.26 ㎍/㎥. Study results indicated that under the particulate matter concentration of 32.75 ㎍/㎥, all three filters were capable of removing more than 95% of the fine dust. However at a particulate matter concentration of 67.26 ㎍/㎥, the medium E11 grade filter was only able to remove about 90% of the particulates whereas the HEPA H13 grade filters were able to remove 95% or more of the particulates. The thicker HEPA filter (40T) was also more effective in removing particulates than the thinner HEPA filter (20T) by about 1.6 to 3 percentage points. Based on the findings of this study, it is recommended that HEPA filters of 20T thickness or greater be used during the high air pollution seasons of winter and spring in Korea while medium filters can be used during the other seasons to reduce outdoor air pollution transmission indoors.

열 교환 소자 형상의 CFD 시뮬레이션을 통한 판형 전열 교환기 성능평가 (A Performance Evaluation of Plate Type Enthalpy Exchanger through CFD Analysis of Elements)

  • 강인성;안태경;박진철
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2017
  • In order to better save energy, many buildings have been constructed with high levels of insulation and airtightness in recent years. Additionally, having high quality indoor air has become more relevant, necessitating a ventilating system. This study is aimed at evaluating the performance of a humidity exchanger through computational fluid dynamics (CFD) analysis of elements for the purpose of providing comfortable indoor air and reduced energy consumption. The simulation was conducted with three different shapes (triangle, rectangular, and curve) of heat exchanger elements, in order to find the most effective element. A follow-up simulation then proved the efficiency of the chosen humidity exchanger, which was selected by analyzing the results of the preceding simulation, comparing study data with measurement data from the Korea Testing Laboratory (KTL). The resulting analysis revealed that the rectangular element showed the lowest level of efficiency in both heating and cooling, while the curved element showed the highest level of efficiency in both heating and cooling.

외기 온·습도 변화에 따른 종이재질 전열교환 엘리먼트 성능에 관한 연구 (Thermal Performance of an Enthalpy Exchanger Made of Paper at Different Outdoor Temperatures and Humidities)

  • 김내현;이을종;송길섭;오왕규
    • 대한기계학회논문집B
    • /
    • 제34권7호
    • /
    • pp.697-702
    • /
    • 2010
  • 전열교환 엘리먼트는 열회수형 환기유닛의 핵심부품으로, 외기와 실내공기의 열 및 수분교환이 이루어진다. 본 연구에서는 현재 국내에서 사용되고 있는 전열교환 엘리먼트에 대하여 외기의 온 습도 변화가 전열교환 엘리먼트의 성능에 미치는 영향을 실험적으로 연구하였다. 전열교환 엘리먼트를 통과 하는 공기 유량, 입 출구의 건 습구 온도를 정밀하게 측정할 수 있는 실험장치를 특별히 제작하였고, 항온항습실내에서 외기의 상대습도 또는 절대습도를 변화시키며 실험을 수행하였다. 실험결과는 현열전달 유용도과 잠열전달 유용도으로 평가되는데 잠열 전달 유용도는 외기의 상대습도의 증가에 따라 증가하였으나 절대습도의 변화에는 거의 무관하게 냐타났다. 한편 현열 교환 유용도는 외기의 온도 및 습도 변화에 무관하게 일정하였다.

보어홀 전열저항이 보어홀 길이에 미치는 영향에 관한 연구 (A Study of the Effect of Borehole Thermal Resistance on the Borehole Length)

  • 이세균;우정선
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.20-27
    • /
    • 2009
  • The effect of borehole thermal resistance on the borehole length is studied. In performing this work a new concept BLRR(borehole length reduction rate) is developed based on the line source model. The solution of line source model is shown to be valid through the comparison with the data of thermal response test. It is shown that BLRR is a function of soil thermal conductivity(k) and borehole thermal resistance($R_b$). The value of BLRR increases with increasing k, which means reducing $R_b$ is more effective when k is high. The reduction of borehole length with change of $R_b$ is easily estimated with BLRR. The validity of BLRR is also examined with EED analysis.

전열교환기의 세대내 풍량 분배를 위한 CFD를 이용한 최적설계방안 (Optimal Design for Airflow Distribution of Total Heat Exchanger in House Using CFD)

  • 김진호;송난정;이건태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.701-705
    • /
    • 2009
  • After revision of law of architecture in 2006, all houses which have more 100 households must has ventilation unit for the indoor air quality. Optimal design of the natural and the mechanical ventilation has being considered. In this paper, it is carried out about optimal design for airflow distribution of total heat exchanger in houses using CFD. As the result, first design of ventilation has some problem in porch area. Adding diffusers in porch area and changing diffuser schedule make more efficient ventilation than original design.

  • PDF

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

다공의 전열판이 내장된 공기 대 공기 전열교환기의 성능 평가 (Performance Evaluation of Air-to-Air Total Heat Transfer with Rotating Porous Plates)

  • 임태우;조동현
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.20-25
    • /
    • 2007
  • The performance of air-to-air heat exchanger has been investigated with rotating porous plates newly developed in this study. With an equal interval of 18 mm, the rotating porous plates are installed inside the heat exchanger where the hot and cold airs enter at opposite ends. When flowing in opposite directions by the separating plate installed in the center of the rotating porous plates, the airs give and receive the heat each other. Dry bulb temperature is set by adjusting heat supply at heater. In order to measure the temperature distribution of the hot air side inside heat exchanger, the thermocouples are inserted between the plates. The first location of thermocouple is 10mm downstream from the inlet of heat exchanger, and succeeding ten locations are aligned at an equal interval of 18mm. From the experiment of air-to-air heat exchanger with the rotating porous plates, the heat transfer rate increased as both air flow rate and RPM of the rotating porous plate increased. It was found that the overall heat transfer coefficient increased with the increase in RPM of porous plate at the conditions of the same air flow rate.

  • PDF

종이 물성이 전열교환 엘리먼트 성능에 미치는 영향 (Effect of Paper Properties on the Performance of a Enthalpy Exchanger)

  • 김내현;조진표;송길섭;김동훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.414-418
    • /
    • 2008
  • The effects of paper properties such as density, air permeability, water vapor transmission rate on the thermal performance of plate-type enthalpy exchanger were experimentally investigated. Three enthalpy exchanger samples having different properties were made, and were tested according to the standard test procedure (KS B 6879). Effective efficiencies were defined, which accounted for the air leakage between supply and exhaust streams. Results showed that paper density affected the sensible heat transfer of the samples. Sensible heat transfer increased with density of the paper. It was also shown that water vapor transmission rate alone was not a proper indicator for the efficiency of latent heat transfer. Air permeability should also be considered for adequate evaluation of the latent heat transfer. Best performance was obtained for the sample having highest paper density and moderate water vapor transmission ratio.

  • PDF

직접접촉응축 열교환기의 분류 및 응용 (Classification and Applications of Direct Contact Condensation Heat Exchanger)

  • 오후규;김성규
    • 기계저널
    • /
    • 제35권7호
    • /
    • pp.638-646
    • /
    • 1995
  • 직접접촉 얼교환 기술은 냉각탑, 접촉급수 가열기 및 공기분리기 등과 같은 장치에 예전부터 이용되어 왔는데, 그 주요한 적용이유는 가열유체와 수열유체의 사이에 일어나는 전열이 일반 열교환기와는 달리 고체벽(금속 열전달표면)을 통과하지 않고 열교환을 함으로써, 종래의 열교 환기에 비하여 상대적으로 설비의 간단화, 부식 및 스케일 부착문제가 경감됨에 따른 적은 유 지보수비 및 높은 열전달률을 얻을수 있는 이점이 있으며, 저 온도차에서의 효율적인 사용이 가능하기 때문이다. 이 글에서는 직접접촉응축 현상의 장점을 이용하는 직접접촉식 교환기의 구조와 형태, 그리고 그 응용분야에 대해서 알아보고자 한다.

  • PDF

재생증발식 냉방기를 이용한 환기 냉방시스템의 성능해석 (Performance Simulation of a Ventilation System Adopting a Regenerative Evaporative Cooler)

  • 장영수;이대영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.8-15
    • /
    • 2011
  • Cooling load reduction was analysed of a ventilation system adopting a regenerative evaporative cooler. The regenerative evaporative cooler is a kind of indirect evaporative cooler which cools the air down to its inlet dewpoint temperature in principle without change in the humidity ratio. The regenerative evaporative cooler was found able to cool the ventilation air to $18{\sim}21^{\circ}C$ when the outdoor condition ranges $25{\sim}35^{\circ}C$ and 0.01~0.02 kg/kg. When the outdoor humidity ratio is lower than 0.018 kg/kg, the regenerative evaporative cooler was found to provide cooling performance enough to compensate the ventilation load completely and to supply additional cooling as well. Energy simulation during the summer was carried out for a typical office building with the ventilation system using the regenerative evaporative cooler. The results showed that the seasonal cooling load can be reduced by about 40% by applying the regenerative evaporative cooler as a ventilation conditioner. The reduction was found to increase as the outdoor temperature increases and the outdoor humidity ratio decreases.