• Title/Summary/Keyword: 전압 안정도 지수

Search Result 31, Processing Time 0.031 seconds

Effect of Sintering Time on Degradation Characteristics of ZPCCY-Based Varistors (ZPCCY계 바리스터의 열화특성에 미치는 소결시간의 영향)

  • 남춘우;박종아
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.6
    • /
    • pp.464-470
    • /
    • 2004
  • The electrical stability of ZPCCY-based varistors composing of ZnO-Pr$_{6}$O$_{11}$-CoO-C $r_2$ $O_3$- $Y_2$ $O_3$ ceramics were investigated in various DC accelerated aging stress with sintering times. Sintering time greatly affected electrical properties and stability. Sintering time decreased nonlinear exponent in the range of 51.2∼23.8 and increased leakage current in the range of 1.3∼5.6 ${\mu}$A. The varistor sintered for 1 h exhibited high nonlinearity, whereas relatively low stability. On the contrary, the varistor sintered for 3 h exhibited low nonlinearity, whereas relatively high stability. But the varistor sintered for 2 h exhibited not only good nonlinearity, with nonlinear exponent of 38.6 and leakage current of 3.6 ${\mu}$A but also high stability, in which the variation rates of varistor voltage, nonlinear exponent, leakage current, and dissipation factor are -0.80%, -1.81 %, +74.4%, and +0.88%, respectively.

A development of multiple substation hybrid control algorithm using local subsystem data (지역 계통 정보를 이용한 다기 변전소 협조제어 알고리즘 개발)

  • Choi, Yun-Hyuk;Kang, Sang-Gyun;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.22_23
    • /
    • 2009
  • 자동화된 변전소의 전압 - 무효전력을 효율적으로 제어하기 위해서는 계통 상태에 따른 운전전략이 필요하다. 즉, 계통의 상태를 파악할 수 있는 안정도 지수를 이용하여, 그에 따른 ULTC와 S.S의 운전 방안의 수립이 요구된다. 이러한 사실을 바탕으로 본 논문에서는 사고 발생 시 계통 안정도를 유지할 수 있는 예방제어 측면과 계통 정보 모니터링을 통한 Tap과 S.S 사이의 협조제어 알고리즘을 제안한다.

  • PDF

Improving the characteristics of Xe dielectric barrier discharge lamp. (제논 유전체 장벽 방전형 램프의 성능 개선에 관한 연구)

  • Park, Ji-Su;Song, Myong-Hun;Jang, Sang-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.147-150
    • /
    • 2007
  • 본 논문은 일반조명용과 LCD Backlight에 적용 가능한 제논 유전체 장벽형 평판형광램프에 대한 연구이다. 일반적으로, 수은을 포함한 형광램프는 낮은 온도에서의 휘도문제와 상대적으로 긴 점등시간, 수명, 그리고 환경 문제가 있다. 이러한 문제점들을 해결하기 위해서 제논 유전체 장벽형 평판형광램프가 연구되었다. 100(W)급($384{\times}321{\times}10mm$)으로 제작된 램프는 AC 펄스 전압에 의해 균일도, 안정한 방전, 우수한 전기적 및 광학적 특성을 가진다. 더 높아진 효율은 빠른 상승시간을 가진 AC 펄스전압, 주파수와 듀티의 구동 최적화, 전극의 형상, 압력 최적화 등에서 얻어진다. 이 연구에서 제논 유전체 장벽형 평판형광램프는 90(%)의 균일 도에서 7,600(cd/$m^2$)의 휘도와 32[1m/W] 이상의 효율을 얻었다.

  • PDF

Electrical Stability of Zn-Pr-Co-Cr-Dy Oxides-based Varistor Ceramics (Zn-Pr-Co-Cr-Dy 산화물계 바리스터 세라믹스의 전기적 안정성)

  • 남춘우;박종아;김명준;류정선
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.11
    • /
    • pp.1067-1072
    • /
    • 2003
  • The electrical stability of the varistor ceramics composed of Zn-Pr-Co-Cr-Dy oxides-based varistors was investigated at 0.0∼2.0 mol% Dy$_2$O$_3$ content under DC accelerated aging stress. The ceramic density was increased up to 0.5 mol% Dy$_2$O$_3$ whereas further addition of Dy$_2$O$_3$ decreased sintered ceramic density. The density sailently affected the stability due to the variation of conduction path. The nonlinearity of varistor ceramics was greatly improved above 45 in the nonlinear exponent and below nearly 1.0 ${\mu}$A by incorporating Dy$_2$O$_3$. Under 0.95 V$\_$1mA/150$^{\circ}C$/24 h stress state, the varistor ceramics doped with 0.5 mol% Dy$_2$O$_3$ exhibited the highest electrical stability, in which the variation rates of varistor voltage, nonlinear exponent, and leakage current were -0.9%, -14.4%, and +483.3%, respectively. The variation rates of relative permittivity and dissipation factor were +7.1% and +315.4%, respectively. The varistors with further addition of Dy$_2$O$_3$ exhibited very unstable state resulting in the thermal runaway due to low density.

A S/C/X-Band GaN Low Noise Amplifier MMIC (S/C/X-대역 GaN 저잡음 증폭기 MMIC)

  • Han, Jang-Hoon;Kim, Jeong-Geun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.5
    • /
    • pp.430-433
    • /
    • 2017
  • This paper presents a S/C/X-band LNA MMIC with resistive feedback structure in 0.25 um GaN HEMT process. The GaN devices have advantages as a high output power device having high breakdown voltage, energy band gap and stability at high temperature. Since the receiver using the GaN device with high linearity can be implemented without a limiter, the noise figure of the receiver can be improved and the size of receiver module can be reduced. The proposed GaN LNA MMIC based on 0.25 um GaN HEMT device is achieved the gain of > 15 dB, the noise figure of < 3 dB, the input return loss of > 13 dB, and the output return loss of > 8 dB in the S/C/X-band. The current consumption of GaN LNA MMIC is 70 mA with the drain voltage 20 V and the gate voltage -3 V.

The Development of Probabilistic Power Quality Evaluation Method for Electrical Distribution System (배전시스템 전기설비 구성에 따른 확률론적 전력품질의 정량적 평가기법 개발)

  • Kim, Yong-Ha;Lee, Sung-Jun;Woo, Sung-Min;Lim, Hyun-Sung;Son, Seung-Ki;Ku, Min-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.34-43
    • /
    • 2007
  • This paper presents a methodology on the AHP(Analytic Hierarchy Process) to calculate unified power quality index which provide an overall assessment of the distribution system performance. To obtain the unified power quality index. we propose the use of the AHP model and consider contingency using Monte Carlo simulation. The proposed method is especially useful and effective for planning. We have applied the proposed method to an actual relatively large system.

A Study on the Quantitative Evaluation of Arc Stability in AC SMAW (교류 피복 아크 용접에 있어서 아크 안정성의 정량적 평가에 관한 연구)

    • Journal of Welding and Joining
    • /
    • v.16 no.4
    • /
    • pp.125-135
    • /
    • 1998
  • The shielded metal arc welding (SMAW) by AC power source was performed to evaluate the arc stability by arc monitoring and analysing. In this study, the arc stability index was evaluated quantitatively by using he coefficient of resistance variation for welding time. This coefficient was obtained for the long time (20sec.) by analysing the waveforms of welding current, voltage and resistance. The coefficient was applied to indicate numerically the variation level of arc length and the degree of arc extinction. Using the coefficient of resistance variation in practical welding, the arc stability of the high titanium oxide electrode (KS E4313) turned out to be better than that of the low hydrogen electrode (KS E4316). In evaluating the skill level of welders by the coefficient, the horizontal fillet weaving welding became clear to be very discriminating because the higher level welder could weave in keeping constant arc length, but the lower level welder showed the characteristics of weaving with the unstable arc length. And it was confirmed that the welding defects as blow holes was formed when the arc stability index were high.

  • PDF

Estimation of Voltage Instability Index Using RLS(Recursive Least Square) (RLS(Recursive Least Square)를 이용한 전압안정도 지수 평가)

  • Jeon, Woong-Jae;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.279-281
    • /
    • 2006
  • A Voltage Instability Predictor(VIP) estimates the proximity of a power system to voltage collapse in real time. Voltage Instability Index(Z-index) from VIP algorithm is estimated using LS(Least Square) method. But this method has oscillations and noise of result due to the system's changing conditions. To suppress oscillations, a larger data window needs to be used. In this paper. I propose the new other method which improves that weakness. It uses RLS(Recursive Least Square) to estimate voltage instability index without a large moving data window so this method is suitable for on-line monitor and control in real time. In order to verify effectiveness of the algorithm using RLS method, the method is tested on HydroQuebec system in real time digital simulator(HYPERSIM).

  • PDF

A Study on the Stability of Praseodymium-Based Zinc Oxide Varistor with Tittria Additives. (이트리아가 첨가된 프라세오디뮴계 산화아연 바리스터의 안정성에 관한 연구)

  • 남춘우;박춘현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.842-848
    • /
    • 1998
  • The stability of paraseodymium-based zinc oxide varistor consisting of Zn-Pr-Co-Cr-Y oxide was investigated according to yttria additives under different stress conditons, such as 0.8V\ulcorner\ulcorner/373K/12h and 0.85V\ulcorner\ulcorner/393K/12h. Wholly, all varistor after the stress showed nearly symmetric and stable I-V characteristics. Particularly, in the case of 2.0mol% and 4.0mol% yttria-added varistor showing a good I-V characteristics, the varation rate of varistor voltage were less 1% and that of nonlinear coefficient were about degree of 5%, and what is remarkable, leakage current with increasing stress time during the applied stress was almost constant. It the light of these facts, it is estimated that varistor constituents having 2.0mol% and 4.0mol% yittria, respectively, will be utilized to various application fields.

  • PDF

A Study on Voltage Stability Assessment Using the Reactive Reserve Iindex (무효전력 예비력 지수를 이용한 전압안정도 평가 방안에 관한 연구)

  • Seo, Sang-Soo;Lee, Byong-Jun;Nam, Su-Chul;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.457-458
    • /
    • 2007
  • The reactive reserves of generators is close to voltage stability. This characteristic has led to the development of a few year monitoring the reactive reserves. In this paper, the reactive reserves have been calculated considering the generator capability curve. In addition, through dividing the systems using electric distance, the reactive reserves of each area has been calculated. Then, using the correlative relationship between reactive reserves and PV margins, the method for monitoring the voltage stability is proposed. The proposed method is tested on PSS/E test system and KEPCO system.

  • PDF