• Title/Summary/Keyword: 전압 변압기

Search Result 600, Processing Time 0.025 seconds

Cascade 3-Phase IHCML Inverter using Maximal Distension Vector Control (최근접 벡터 제어기법을 이용한 cascade 3상 IHCML 인버터)

  • Park, Jin-Hyun;Park, Sung-Jun;Song, Sung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.101-109
    • /
    • 2009
  • In this paper, a new method, cascade 3 phase IHCML(Isolated H-bridge Cascade Multi-Level) inverter and a control method is proposed by using two 3-phase transformers that have respectively different transformation rates. Vector control technique in which the highest proximity vector has been used is also put into use. With this process, the switching frequency is almost identical with the output fundamental frequency, which makes less switching loss, and the switching frequency of the small volume of the H-bridge that is in charge of small power is highly controlled, which improves the quality of the output voltage.

Series Compensation Analysis of Transmission Line using Inverter-type Var Compensator (인버터식 무효전력보상기에 의한 송전선로의 직렬보상 특성해석)

  • 한병문;한경희;신익상
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.4
    • /
    • pp.28-35
    • /
    • 1997
  • 본 논문에서는 송전선로에 직렬로 삽입되어 선로의 리액턴스를 동적으로 보상하는 인버터식 직렬보상기에 대한 동적 응동 해석을 기술하고 있다. 이 직렬보상기는 다중펄스로 동작하는 전압원인버터와 결합변압기, 그리고 제어장치로 구성되어 있으며, 점호각을 조절하여 선로의 리액턴스를 가변하고 용량성 뿐만 아니라 유도성 보상도 가능하다. 이 보상기로 선로의 리액턴스를 감소시키면 전송 유효전력의 증각가 가능한데, 이러한 효과를 본 논문에서는 단일기-무한대-버스 전력계통에 대해 EMTP를 이용한 시뮬레션으로 확인하였으며, 또한 축소모형 제작과 실험을 통해 실험적으로 확인하였다.

  • PDF

Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves (초음파를 이용한 에폭시 몰드변압기의 열화 진단)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 1999
  • Measurements of ultrasonic signals caused by partial discharges were perlonnrl by using an ultrasonic measurement technique to diagnose the electrical treeing deterioration in an epoxy mold-type power transformer. We also examined the characteristics of tree growth, partial discharge magnitude and ultrasonic pulse number with the increase of the deterioration time. From these results, it was found that the shape of the tree was a branch-type, and the rates of the tree growth were examined when ac voltages of 16[kV] and 20[kV] were applied Ultrasonic pulse number and discharge magnitude were rapidly increased as the length of the tree grows after the middle stage of the deterioration time, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, time-delaying and directivity characteristics of ultrasonic signals propagated into epoxy resin by using ultrasonic oscillation and receiving systems are also re[prted as a basic data of ultrasonic mesasurements in mold-type power transformer.former.

  • PDF

Current Limiting and Voltage Sag Compensation Characteristics of Flux-Lock Type SFCL Using a Transformer Winding (변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 및 전압강하 보상 특성)

  • Ko, Seok-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.1000-1003
    • /
    • 2012
  • The superconducting fault current limiter (SFCL) can quickly limit the fault current shortly after the short circuit occurs and recover the superconducting state after the fault removes and plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the flux-lock type SFCL with an isolated transformer, which consists of two parallel connected coils on an iron core and the isolated transformer connected in series with one of two coils, has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. The current limiting and the voltage sag compensating characteristics of a SFCL using a transformer winding were analyzed. Through the analysis on the short-circuit tests results considering the winding direction of two coils, the SFCL designed with the additive polarity winding has shown the higher limited fault current than the SFCL designed with the subtractive polarity winding. It could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

Development of the Lithium Polymer Battery Charger Using the Small Fuel Cell (소형 연료전지를 이용한 리튬 폴리머 배터리 충전기의 개발)

  • Kim, Tae-Hoon;Lee, Jong-Hak;Lee, Seung-Joon;Choi, Woojin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.73.2-73.2
    • /
    • 2010
  • 휴대용 전자기기들의 소비전력 증가에 따라 2차전지에 비해 에너지 밀도가 높은 연료전지를 이용한 충전기의 필요성이 부각되고 있다. 대다수의 충전기는 On-Grid 방식으로 벅타입 컨버터를 이용한 감압 방식이었으나, 연료전지를 이용할 경우 승압식 컨버터를 통한 배터리의 충전이 요구된다. 또한 배터리는 일반 저항부하와 달리 큰 커패시턴스 성분을 가지고 있기 때문에 컨버터의 출력단에 인덕터가 없는 경우 큰 출력 리플전류를 유도하게 되어 시스템의 효율과 배터리의 수명에 좋지 않은 영향을 끼치게 된다. 또한 이를 해결하기 위해 절연형 감압 컨버터를 사용하는 경우 변압기 사용에 의한 부피 증가와 부가 소자의 사용에 따른 가격 상승을 피하기 어렵다. Cuk 컨버터는 주스위치의 ON/OFF 동작에 관계없이 출력으로 에너지가 항상 전달되며, 이상적으로 리플이 거의 존재하지 않아 충전용으로 적합하다. 또한, 승압 및 감압이 자유롭기 때문에 배터리의 정격전압에 상관없는 범용 충전기의 설계도 가능하다. 따라서 본 논문에서는 Cuk 컨버터를 이용하여 배터리 충전기를 설계하고, 그의 상태공간 모델링, 주파수 특성 해석 및 제어기 설계에 대해 기술한다. 제안된 제어 방식은 소형 연료전지 스택을 이용하여 실제 배터리를 대상으로 한 정전류 및 정전압 제어를 실행하여 그 성능 및 안정성을 검증한다.

  • PDF

The Electric Field Analysis of 2[MVA] Mold Transformer Considering the Void Effect in the Insulating Material (2[MVA] 몰드변압기 절연물내 기포 영향을 고려한 전계해석)

  • Kim, Chang-Eob;Jeon, Mun-Ho;Lee, Suk-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.177-184
    • /
    • 2010
  • This paper presents the electric field analysis for 2[MVA] mold transformer using finite element method. The electric field was calculated for the voltage applied to the mold transformer without voids in the insulating material. Then, it was analysed the maximum electric field when the voids was in the insulating materials. And the starting voltage of partial discharge was predicted due to the voids. The effects of voids in epoxy resin on the electric field were investigated for different sizes, shapes, positions and arrangements of voids.

A Study on the Harmonic of the electrical Installations in Apartment Housing (아파트 전기설비에서의 고조파 실태 분석 연구)

  • 이기홍;성세진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.2
    • /
    • pp.105-110
    • /
    • 2001
  • To analysis the effect by the Harmonics through Power facilities in Apartment housing, This paper measured the Harmonics at Lighting Transformer, Power Transformer and Services-entrance Conductors of electrical installation in apartment housing. The measured result is following as : 1) The Harmonics at Lighting Transformer is generated in the large of the 5th Harmonics. 2) The Harmonics at Power Transformer is generated in the large of the 5th and 7th Harmonics. And then 3) The THD at the Services-entrance Conductors is average 2.4[%], which is compared to the measuring Voltage, this meaning value is good condition until now against Harmonics effect. But, So the large capacitance of household electrical alliances with rectifiers in the future considered the effect of Harmonics at the Electric Power planning in apartment Housing.

  • PDF

Characteristics of Piezoelectric Transformer Using PMS-PZT, PMN-PZT Ceramics (PMS-PZT, PMN-PZT계 세라믹스를 이용한 압전변압기의 특성)

  • 이동균;안형근;한득영;윤석진;김현재
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.3
    • /
    • pp.220-226
    • /
    • 2000
  • The piezoelectric material for piezoelectric transformer needs the high electromechanical coupling factor( $k_{p}$) the piezoelectric constant( $d_{33}$) and the mechanical quality factor( $Q_{m}$)in order to obtain high voltage step-up ratio and low temperature rising. In this study the piezoelectric transformers were fabricated using Pb[$Zr_{0.45}$/ $Ti_{0}$48//L $u_{0.02}$(M $n_{1}$3//S $b_{2}$3/)$_{0.05}$$O_3$(PMS-PZT) and Pb[Z $r_{0.25}$/ $Ti_{0.375}$(M $g_{1}$3//N $b_{2}$3/)$_{0.375}$$O_3$+0.5wt%Mn $O_2$(PMN-PZT) ceramics. The piezoelectric properties of PMS-PZT and PMN-PZT were measured. The voltage set-up ratios of the piezoelectric transformers using PMS-PZT and PMN-PZT were the value of 15, 20 respectively under 100$_{KΩ}$ in Rosen type transformer.r.ormer.r.r.r.r.r.r.

  • PDF

Harmonic Analysis of Power Conversion System for Torque and Speed Changing of Electric Propulsion Ship (전기추진선박의 토크 및 속도변화에 따른 전력변환장치의 고조파 분석)

  • Kim, Jong-Su;Kim, Seong-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.1
    • /
    • pp.83-88
    • /
    • 2011
  • There are various environmental conditions under which ship may navigate over ocean or in harbor. Ship's torque and speed change frequently under the voyage conditions. In this case, harmonics is created in the electrical power systems. The major adverse impacts of voltage and current harmonics in the electrical power systems on generator, transformer, converter, inverter and propulsion motor lead to the increase of machine heating caused by iron and copper losses which are dependent on frequency. In this paper, an analysis of THD(total harmonic distortion) for currents and voltages in the propulsion equipment was carried out. The THD and torque ripple in the input currents of the propulsion motor have been confirmed by the simulation results.

Harmonic Reduction of Electric Propulsion Ship by Multipulse Drive (다중펄스 드라이브에 의한 전기추진선박의 고조파 저감)

  • Kim, Jong-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.425-431
    • /
    • 2011
  • The harmonic distortion level may be significant in electric propulsion systems, as the main loads usually are variable speed propulsion/thruster drives. Distortion of currents and supply voltage waveforms may lead to: Increased power dissipation(losses) in equipment connected to the network, such as generators, motors, transformers, cables, etc., from the harmonic currents, may cause overheating and deterioration of the insulation, and reduced life time of the equipment. In this paper introduced the canceling method of harmonic currents by a multipulse drive with phase shifting transformer. The simulation results indicated a good speed response to the middle speed range of electric propulsion motor. And also, THD(total harmonic distortion) and torque ripple could be reduced in comparing the 12-pulse drive with 6-pulse drive.