• Title/Summary/Keyword: 전압 발생기

Search Result 1,068, Processing Time 0.029 seconds

Enhanced Performance of Li Metal Negative Electrode using Protection Film by Carbon Black and Polymeric Binder (카본블랙과 고분자 바인더로 구성된 보호필름을 통한 리튬금속 음극의 성능개선)

  • Noh, Seong Ho;Ryu, Da Young;Jang, Young Seok;Ryu, Ji Heon
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2022
  • In this study, the surface protection film based on organic-inorganic composite is manufactured for suppressing lithium dendrite growth, and the film is applied on the surface of Li metal negative electrode for lithium metal batteries (LMBs). The film is consist of the polyvinylidene fluoride (PVDF) polymeric binder which has good mechanical strength and high electrochemical stability, and carbon black (Super-P) which has outstanding electrical conductivity as the inorganic compound. First, in order to confirm the suppression of the internal short circuit by the lithium dendrite, the time required for the short circuit is measured while a constant current is continuously applied. As a result, the internal short circuit is delayed in proportion to the carbon black content of the film, and it is significantly delayed than bare Li metal electrode which does not use protection film. The cycle performance of the thick protection film (8 ㎛), is worse than that of the thin film (4 ㎛). However, as the carbon black content of the film increased, the cycle performance is improved. Thus, the surface protection film based on carbon black/PVDF composite can delay the internal short circuit, and has low overvoltage during the cycle. However, more stable cycle performance needs to be built through further improvements.

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF

Chemical Age Dating of Zircon and Monazite by E1ectron Microprobe (전자현미분석기를 이용한 저어콘 및 모나자이트의 화학적 연대 측정법)

  • 이석훈
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.179-189
    • /
    • 2001
  • The determination of trace concentration of U, Th and Pb was carried out for chemical dating of zircon and monazite by electron microprobe. Detection limit and error range should be considered to measure characteristic X-rays of M-line from those minerals, which are low in the ionization of atom and low peak intensity in the spectrum. The element of U, Th and Pb were simultaneously measured with 3 spectrometers equipped with PET crystal to reduce a total counting time and error due to drift of instrumental operating condition. Detection limit could be improved from increase of the peak/background ratio through adjusting pulse height analyzer about 1000 mv baseline. Under permissible maximum analytical conditions, theoretical detection limit of U, Th and Pb is down to 30 ppm (99% confidence level). The analytical result was maintained at a relative error $\pm$10% ($2{\sigma}$) in 800 ppm Pb, $\pm$5% ($2{\sigma}$) in 2330 ppm U and $\pm$10% ($2{\sigma}$) in dating from a single measurement of zircon at 15 keV and 100 nA. However, for the precise dating of zircon and monazite, if it is considered a 3 $\mu\textrm{m}$ spatial resolution, <100 ppm ($3{\sigma}$) detection limit and <$\pm$10% ($2{\sigma}$) relative error, optimum analytical conditions are given as 15~20 keV accelerating voltage, 100~200 nA beam current and 300~1200 sec total counting time. To reduce material damage by high current, there is need to be up to 3~5 $\mu\textrm{m}$ of electron beam diameter, or to use arithmetic average of multiple measuring at a shorter counting time. A younger or relatively low concentration rocks can be dated chemically by lower detection limit and improved precision resulted from increase of current and measuring time.

  • PDF

Characterization of the Stretch-Activated Channel in the Hamster Oocyte (햄스터난자에서 신전에 의해 활성화되는 통로의 성상)

  • Kim, Y.-M.;Hong, S.-G.
    • Journal of Embryo Transfer
    • /
    • v.19 no.2
    • /
    • pp.89-99
    • /
    • 2004
  • Stretch-activated channels (SACs) responds to membrane stress with changes in open probability (Po). They play essential roles in regulation of cell volume and differentiation, vascular tone, and in hormonal secretion. SACs highly present in Xenopus oocytes and Ascidian oocytes are suggested to be involved in the regulation of pH and fluid transport to balance the osmotic pressure, but remain unclear in mammanlian oocytes. This study was investigated to find the presence of SACs in hamster oocytes and to examine their electrophysiological properties. To infer a role of SAC in relation to the development of early stage, we followed up to the stage of two-cell zygote with patch clamp techniques. Single channels were elicited by negative pressure (lower than ­15 cm$H_2O$). Interestingly, SACs were dependent on permeable cations such as $Na^+$ or $K^+$. As permeable cation removed from both sides across the membrane, SAC activity completely disappeared. When permeable cations present only in intracellular compartment, outward currents appeared at positive potentials. In contrast to this, inward currents occurred only at the negative voltage when permeable cation absent in cell interior. These result suggests that SAC carry cations through the nonselective cation channel (NSC channel). Taken together, we found that stretch activated channels present in hamster oocyte and the channel may carry cations through NSC channels. This stretch activated-NSC channels may play physiological role(s) in oocyte growth, maturation, fertilization and embryogenesis in fertilized oocytes to two-cell zygotes of hamster.

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Clinical Application of Stent-graft in Thoracic Aortic Diseases (흉부 대동맥 질환에서 스텐트-그라프트의 임상적 적용)

  • Kim, Kyung-Hwan;Lee, Cheul;Chang, Ji-Min;Chung, Jin-Wook;Ahn, Hyuk;Park, Jae-Hyung
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.698-703
    • /
    • 2001
  • Background: Endovascular stent-graft insertion in aortic diseases is now generally accepted as an attractive alternative treatment modality. We reviewed our clinical experiences of endovascular stent-graft insertion in thoracic aorta. Material and Method: Since 1995, we performed 8 cases of endovasclar stent-graft insertion. Preoperative diagnoses were aortic aneurysms in 4, traumatic aortic ruptures in 3, and ruptured aortic pseudoaneurysm in 1. All procedures were performed in angiography room with the guidance of fluoroscopy. The stent-graft device is a custom-made 0.35mm thickness Z-shaped stainless steel wires, intertwined with each other using polypropylene suture ligation. It is covered with expanded Dacron vascular graft. Result: All procedures were performed successfully. Follow-up studies revealed 2 minimal perigraft leakages. There was no significant leakage or graft migration. 2 patients expired due to multiple organ failure and fungal sepsis. Other survivors(6) are doing well. Conclusion: Endovascular stent-graft insertion is relatively saft and effective treatment modality in the managment of various types of aortic diseases. In may be an effective alternative in aortic diseases of great surgical risk.

  • PDF

Detection of Respiratoiry Tract Viruses in Busan, 1997-2000 (1997-2000년 부산지역 호흡기계 바이러스의 탐색)

  • 조경순;김영희
    • Korean Journal of Microbiology
    • /
    • v.37 no.4
    • /
    • pp.284-288
    • /
    • 2001
  • Respiratory viruses are one of the most infectious agent in human. Six different respiratory tract viruses were detected from Busan while working on the preventive surveillance in 1997-2000. The isolation rate from suspected specimens were 8.4%. Influenza virus A, B type, parainfluenza virus, adenovirus, mumps virus, and measles virus were examined from throat swabs, serum, and secretions of patients. Influenza A/Sydney/05/97(H3N2)-like, A/Johanesburg/33/94(H3N2)-like, A/Beijing/262/95(H1N1)-like and Influenza B/Beijing/262/95-like, B/Harbin/07/94-like, B/Guangdong/08/93-like were found. Adenovirus serotype 1, 2, 3 and 5 were detected, antibody of mumps both IgM and IgG were shown and outbreaks of measles were confirmed. Different antigenic types of influenza virus were detected every year, one outbreak of parainfluenza in 1999, mumps outbreak in 1999 and 2000, and incidence of measles in 2000 were noticeable. Monthly outbreaks were November through following March with influenza virus, January through June with adenovirus, February through May and December with mumps, April through August and November, December with measles, respectively. The size of isolated viruses were 130 nm with influenza virus B type, non-enveloped, icosahedron with 70 nm with adenovirus, 170 nm with mumps virus and 180 nm with parainfluenza virus in diameter, respectively.

  • PDF

The Heat Transfer Performance of a Heat Pipe for Medium-temperature Solar Thermal Storage System (중온 태양열 축열조용 히트파이프의 열이송 성능)

  • Park, Min Kyu;Lee, Jung Ryun;Boo, Joon Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.69-69
    • /
    • 2011
  • 태양열 발전 플랜트에 사용되는 중고온 범위의 축열조에 고체-액체간 상변화를 수행하는 용융염을 축열물질로 사용하면 액체상 또는 고체상만으로 된 열저장 매체에 비해 축열조의 규모를 축소함과 동시에 축열온도의 균일성 향상에 기여할 수 있다. 중온인 $250{\sim}400^{\circ}C$ 범위에서 이용 가능한 용융염으로는 질산칼륨($KNO_3$), 질산리튬($LiNO_3$)등이 있다. 그러나 이러한 용융염의 가장 큰 단점은 열전도율이 매우 낮다는 것이며, 이로 인해 요구되는 열전달률을 성취하기 위해서는 많은 열접촉면적이 필요하다는 것이다. 이러한 단점을 극복하는 방법을 도입하지 않고서는 축열시스템의 소규화를 성취하는데 큰 효과를 가져올 수 없다. 한편 열수송 성능이 탁월한 히트파이프를 사용하면 열원 및 열침과 축열물질 사이의 열전달 효율을 증가시켜 시스템의 성능 향상과 동시에 소규모화에 기여할 수 있다. 중온 범위 히트파이프의 작동유체로서 다우섬-A(Dowtherm-A)는 $150^{\circ}C$이상 $400^{\circ}C$까지의 범위에서 소수에 불과한 선택적 대안 중 하나이다. 따라서 본 연구에서는 용융염을 사용하는 중온 태양열축열조에 적용 가능한 다우섬-A 히트파이프의 성능을 파악하여 기술적 자료를 제시하고자 하였다. 열원으로는 고온 고압의 과열증기, 그리고 열침으로는 중온의 포화증기를 고려하였다. 용융염 축열조를 수직으로 관통하는 히트파이프는 하단부에서 열원 증기와 열교환 가능하며, 중앙부에서 축열물질과 열교환하고, 상단부에서는 중온 증기와 접촉할 수 있도록 배치하였다. 축열모드에서는 히트파이프의 하단부가 증발부로 작동하고, 중앙부가 응축부로 작동하여 용융염으로 열을 방출하면 용융염의 온도가 상승하고 용융점에 도달하면 액상으로의 상변화가 진행되면서 축열이 활성화된다. 축열모드에서 히트파이프의 상단부는 단열부로 작동한다. 방열과정에서는 히트파이프의 하단부가 단열된 상태이고, 중앙부는 용융염으로부터 열을 받아 증발부로 작동하며, 상단부는 중온 증기로 열을 방출하므로 응축부로 작동한다. 즉, 축열시스템의 작동모드에 따라 하나의 히트파이프에서 증발부, 응축부, 단열부의 위치가 변하게 된다. 특히, 히트파이프의 중앙 부분이 응축부에서 증발부로 전환될 때에도 작동이 보장되려면 내부 작동유체의 연속적인 재순환이 가능해야 하므로, 일반 히트파이프에서와는 달리 초기 작동액체의 충전량을 증발부 전체의 체적보다 더 많이 과충전해야 한다. 이러한 히트파이프의 성능 파악을 위한 실험에서 고려한 변수들은 열부하, 작동액체의 충전률, 작동온도 등이며, 열수송 성능의 지표로서는 유효열전도율과 열저항을 이용하였다. 중온범위에서 적정한 작동온도를 성취하기 위해 실험에서는 전압 조절기로 열부하를 조절하는 동시에 항온조로 응축부의 냉각수 입구 온도를 제어하였다. 하나의 히트파이프에 대해서 최대 1 kW까지의 열부하에서 냉각수 입구 온도를 $40^{\circ}C$에서 $80^{\circ}C$ 범위로 변화시키면 히트파이프 작동온도를 약 $250^{\circ}C$ 내외로 조절 가능하였다. 히트파이프 작동액체 충전률은 윅구조물의 공극 체적을 기준으로 372%에서 420%까지 변화 시켰다. 실험 결과를 토대로 열저항과 유효 열전도율을 각각 입력 열유속, 작동온도, 작동액체 충전률 등의 함수로 제시했다. 동일한 냉각수 온도에서는 충전률이 높을수록 히트파이프의 작동온도가 감소하였다. 열저항 값의 범위는 최소 $0.12^{\circ}C/W$에서 최대 $0.15^{\circ}C/W$까지로 나타났으며 유효 열전도율의 값은 최소 $7,703W/m{\cdot}K$에서 최대 $8,890W/m{\cdot}K$까지 변화했다. 최소 열저항은 충전률 420%인 경우에 나타났는데 이때의 작동온도는 약 $262^{\circ}C$이었다. 히트파이프의 작동한계로서 드라이아웃(dry-out)은 충전률 372%의 경우에 열부하 950 W에서 발생하였으나, 그 이상의 충전률에서는 열부하 1060 W까지 작동한계 발생이 관찰되지 않았다. 실험 결과 본 연구에서의 히트파이프는 중온 태양열 축열조에 적용되어 개당 약 1 kW의 열부하를 이송하면서 축열물질 및 축방열 대상 유동매체와 열교환을 하는데 사용하는데 충분할 것이라 판단된다.

  • PDF