• Title/Summary/Keyword: 전압조정기

Search Result 191, Processing Time 0.034 seconds

A Design of a 5 GHz Low Phase Noise Voltage Tuned Dielectric Resonator Oscillator Using Loop Group Delay (루프 군지연을 이용한 저위상 잡음 5 GHz 전압제어 유전체 공진기 발진기 설계)

  • Son, Beom-Ik;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.3
    • /
    • pp.269-281
    • /
    • 2014
  • In this paper, a systematic design of a low phase noise voltage-tuned dielectric resonator oscillator(VTDRO) using loop group delay is proposed. Designed VTDRO is closed-loop type and consists of a cascade connection of a resonator, phase shifter, and amplifier. Firstly, a reference VTDRO is fabricated and its phase noise and electrical frequency tuning range are measured. Both the phase noise and electrical frequency tuning range depend on the loop group delay. Then, a required value of loop group delay for a new VTDRO with a low phase noise can be systematically computed. In addition, its phase noise and electrical frequency tuning range can be theoretically estimated using those obtained from the measurement of the reference VTDRO. When the loop group delay increases, the phase noise decreases and the electrical frequency tuning range also decreases. The former predominantly depends on the resonator structure. Therefore we propose a systematic design procedure of a resonator with high group delay characteristics. The measured loop group delay of the new VTDRO is about 700 nsec. The measured phase noise of the new VTDRO show a state-of-the-art performance of 154.5 dBc/Hz at 100 kHz frequency offset and electrical frequency tuning range of 448 kHz for a voltage change of 0~10V. The oscillation power is about 4.39 dBm.

A study for Optimal Voltage Control Method of Distribution Systems with Distributed Generation (분산전원 연계 배전개통의 최적전압조정에 관한 연구)

  • Seo, Gyu-Seok;Baek, Young-Sik;Kim, Jung-Nyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.334-336
    • /
    • 2005
  • 최근 생활수준의 향상과 정보통신 산업의 급속한 발전으로 인하여 전 세계적으로 전력품질에 대한 관심이 높아져, 각종 전력품질 개선장치로부터 최적 공급시스템에 이르기까지 다양한 각도에서 전력품질을 향상하기 위한 연구개발이 수행되고 있으며, 특히 정보통신기기 및 정밀제어기기 등의 보급증가로 전압품질에 대한 관심이 높아져가고 있다. 또한 전력소비는 증가하고 있지만 환경문제, 부지확보 문제로 인한 대형 발전 설비의 확충이 어렵고, 전력산업 구조개편으로 인해 분산전원의 도입이 적극 검토되고 있다. 지금까지 배전계통의 전압 관리는 배전용변전소 ULTC(Under Load Tap Changer)와 고압배전선로의 주상변압기에 의해 조정되어 왔다. 하지만 배전용변전소와 고압배전선로의 선로전압조정장치가 서로 독립적으로 운용되고 있기 때문에 선로전압조정장치의 효율성이 떨어지고 있는 실정이다. 또한 분산전원이 도입 한계량에 대한 연구도 지속적으로 이루어지고 있다. 따라서 본 논문에서는 배전계통에서의 최적 전압조정을 위한 전압조정 장치와 분산전원의 도입한계량의 협조 운용 방안을 제시하고자 한다.[1]

  • PDF

A Study of Improvement on the responsiveness of Digital AVR System (Digital 자동전압조정장치(AVR)의 속응성 향상에 관한 연구)

  • Kim, Song-hyun;Lee, Hyung-ki;Choe, Wook-yeon;An, Young-joo;Kim, Hyun-soo;Kim, Gi-Ryang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.246-247
    • /
    • 2015
  • Type of Automatic Voltage Regulator (AVR) can be divided into Analog and Digital Type. Automatic Voltage Regulator (AVR) of the synchronous generators of the brushless type are to be reduced to the voltage fluctuation on the basis of the total load. The PID control method is a general control technique is commonly widely used. In this study, the control target parameter iPID does not reset the parameters of the controller for the variable (Intelligent PID) using the controller synchronous generator Digital automatic voltage to you like all applied to the adjusting device (AVR) the voltage change is small, improved responsiveness was studied in this controller.

  • PDF

The study on the oscillatory frequency and factor(γ) of transient recovery voltage (과도회복전압의 진동주파수와 진폭율에 대한 연구)

  • Kim, Geun-Yong;Sung, Ki-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.652_653
    • /
    • 2009
  • 주어진 조건 하에서 의도하는 기간 동안 요구된 기능을 적절하게 수행하기 위해서는 제품의 신뢰성 확보가 무엇보다도 중요하다. 신뢰성 확보를 위해서는 제품의 안전성 및 내구성에 대한 고려가 충분히 이루어져야 한다. 고빈도 개폐를 목적으로 사용되는 전자기 접촉기 또한 제품의 안전성 및 성능의 신뢰성이 중요한 제품이라 할 수 있다. 그래서 이를 검증하기 위한 전자기 접촉기의 부하개폐동작성능에 대한 평가가 중요한 시험항목으로 부각되고 있다. 그리고 개폐특성을 평가하기 위한 부하는 규정된 과도회복전압특성을 얻을 수 있도록 조정되어야 한다. 본 논문에서는 부하측 중성점 접지 방식의 부하 회로 조정방법을 사용하여 전자기 접촉기의 개폐성능을 평가하기 위한 과도회복전압의 진동주파수와 진폭율의 특성을 고찰하였다.

  • PDF

An Improved Voltage Regulation Method in Power Distribution System Interconnected Multiple PV Systems (다수 PV 시스템 배전계통 연계 시 개선된 전압조정 방법)

  • Kang, Chul;Shin, Hee-Sang;Moon, Jong-Fil;Choe, Gyu-Ha;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • This paper presents the improved voltage regulation method in power distribution system with multiple PV systems. At present, Line Drop Compensator (LDC) method has been used as voltage regulation method of power distribution system, which regulates the voltage using Under Load Tap Changer (ULTC), regarding the power flow of distribution system as one way. However, the method may be not able to regulate the voltage in a permissible range when the power flow is two ways. Thus, in this paper, we present the improved voltage regulation method of power distribution system using the voltage data of the point connected PV systems.

Reactive power Control of Voltage Compensator for stabilization Distribution Line (배전선로 안정화를 위한 전압보상기의 무효전력 제어기법)

  • Seo, Joungjin;Jo, Jongmin;Kim, Yeong-Rok;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.103-105
    • /
    • 2020
  • 본 논문은 저압 배전선로의 전압 조정을 위해 상태관측기와 반복제어기를 적용한 무효전력 제어 알고리즘을 제안하였으며, 시뮬레이션 및 실험으로 이를 검증하였다. 무효전력 보상기는 단상 풀 브리지 인버터 구조이며 전압제어 시 DC 전압을 일정하게 유지하기 위한 전압 제어와 전류 제어기로 구성된다. DC 리플 보상방식은 상태관측기로 만들어낸 출력 값, DC 링크 리플 성분을 보상한 값을 전압제어기 피드백 성분으로 사용하여 전압을 일정하게 제어하였다. 무효전력을 안정하게 주입하기 위해 기본파 성분은 PI제어기로 제어하고 반복제어기를 PI제어기와 병렬로 연결하여 저차 고조파를 보상하였다. 반복 제어기는 동기 좌표계에서 구현됨에 따라 홀수파 고조파 성분을 제거하는 역할을 한다. 제안한 제어기법은 5kVar 단상 인버터 시스템으로 실험을 진행하였으며, 상태관측기와 반복제어기가 적용된 경우 THD가 9%에서 2%로 향상됨을 확인함으로써 제안한 알고리즘의 성능을 검증하였다.

  • PDF

Application of Voltage Controller on Vector Control for Adjusting Output Voltage (출력전압 조정을 위한 전압제어기의 벡터 제어 적용)

  • Lee, Eun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.396-397
    • /
    • 2018
  • 벡터제어는 V/F운전에 비해서 높은 기동 토크와 과부하시 효율적인 전류 제한이 가능한 장점으로 인하여 고성능이 요구되는 부하에 적용이 확대되고 있다. 하지만 출력전압이 V/F운전과 같이 주파수에 따라서 결정되지 않고, 모터파라미터와 D축전류에 의해 결정되므로 정격부하에서 출력전압이 작아지는 경우 출력전류가 정격전류 보다 지나치게 커지는 단점이 있다. 이러한 문제점을 해결하기 위해서 기존 약자속 운전에 적용되었던 전압제어기를 사용하여 출력전압을 제어하는 용도로 사용하고자 한다.

  • PDF

A Study on the Analysis for the Effect of Industrial Customers by Voltage Variations (전압변동이 산업체 수용가에 미치는 영향에 대한 분석에 관한 연구)

  • Kim, Byeong-Mok;Jeong, Jang-Muk;Yoon, Sam-Hee;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.632-635
    • /
    • 2009
  • 본 연구에서는 국내의 전압실태를 파악하고 산업체에 미치는 영향을 분석하기 위하여, 전압측정과 설문조사를 병행하였다. 먼저 전압측정을 위하여 수도권과 비수도권의 중규모 도시를 대상으로 측정지점과 대상선로를 선정하였다. 여기에서는 공장지역을 공급하는 4개의 배전용변전소의 주 변압기(M.Tr)와 5개의 고압선로(D/L)를 선정하여, 주 변압기의 직하전압(송출전압)과 말단의 수용가 단자전압을 5분간 평균치로 설정하여 측정하였다. 한편 설문조사 대전, 충남지역을 대상으로 산업체별로 전화와 설문지를 가지고 방문조사를 수행하여 분석하였다. 본 연구에서는 전압실태의 평가를 엄격하게 하기 위하여, 장거리의 고압선로이거나 부하변동이 심한 최악의 조건을 가지는 고압선로를 대상선로로 선정하였으며, 또한 선로전압조정장치(SVR)가 포함된 선로를 선정하여 고압선로 상에서의 전압조정에 대한 영향도 평가하도록 하였다.

  • PDF

The study on the characteristics of transient recovery voltage of electromagnetic contactor (전자기 접촉기의 과도회복전압 특성에 대한 연구)

  • Kim, Geun-Yong;Ryu, Jae-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.834-835
    • /
    • 2008
  • 전자기 접촉기(electromagnetic contactor)는 교류 또는 직류 저압의 전로(電路)에 사용되는 부하개폐기의 한 종류로 전자석 코일(electromagnet coil)의 여자(勵磁)에 의하여 주 접촉자를 개폐시키는 기기이다. 일반적으로 전자기 접촉기는 단락전류를 차단하도록 설계되어 있지는 않다. 그러므로 설치 시 적절한 단락 보호가 이루어져야 하며, 반드시 접촉기의 일부분일 필요는 없다. 차단기와 퓨즈 등을 단락보호장치(SCPD, Short-Circuit Protective Device)로 많이 사용한다. 전자기 접촉기는 특히 고빈도 개폐를 목적으로 사용되는 개폐기로, 농형모터(squirrel-cage motors)의 시동, 운전 중의 정지, 플러깅(plugging, 모터가 운전하고 있는 중에 모터의 1차측 접속을 역으로 바꿔서 모터를 급격히 정지시키거나 역 회전시키는 것) 및 인칭(inching, 모터를 짧은 기간 동안 1회 또는 반복 여자해서 피동기구를 조금 이동시키는 것)에 많이 쓰인다. 이러한 기기의 개폐특성을 평가하기 위한 부하는 과도회복 전압의 진동 주파수(oscillatory frequency)와 진폭율 ${\gamma}$를 얻을 수 있도록 조정되어야 한다. 본 논문에서는 고빈도 개폐능력을 갖고 있는 전자기 접촉기의 과도회복 전압 특성과 그 특성을 얻기 위한 부하 회로의 조정방법에 대해 고찰하였다.

  • PDF

Economic Evaluation of Step Voltage Regulator in Distribution Systems (배전계통에 있어서 선로전압조정장치의 경제성 평가에 관한 연구)

  • Rho, Dae-Seok;Lee, Eun-Mi;Park, Chang-Ho;Kim, Eung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.140-143
    • /
    • 2003
  • 배전선로에서 부하가 증가함에 따라 주상변압기의 탭 조정만으로는 모든 수용가단 전압을 규정치($220{\pm}6%$) 이내로 유지시킬 수가 없게 된다. 따라서, 수용가단 전압의 품질을 규정치 이내로 유지할 수 있는 보강공사가 필요하게 된다. 현재는 수용가단 전압품질에 문제가 발생하지 않으나, 선로의 부하가 증가 될수록 통과전류의 양이 많아져, 전압강하가 높아지기 때문에 일부 수용가에 저전압이 발생하게 될 가능성이 있게 된다. 여기서는 부하증가(부하증가율 : 1%, 2%, 3%, 4%, 5%)에 대한 대책으로 다음과 같은 3가지 대안을 고려하기로 한다. 본 연구에서는 1) 선로전압조정장치(SVR)의 설치 2) 회선증강(ACSR $95mm^2$ $\rightarrow$ ACSR $160mm^2$) 3) 회선신설(전압강하 5%이상 지점에 회선 추가)에 대한 경제성을 현재가치 환산법에 의해 평가해 보고, 가장 적정한 대안을 제안하여 배전계통 계획 및 운용에 대한 합리적인 투자 대안을 제시한다.