• Title/Summary/Keyword: 전선

Search Result 1,426, Processing Time 0.027 seconds

Distribution of Fish Larvae and the Front Structure of the Korea Strait in Summer (여름철 대한해협의 전선구조에 따른 자치어의 분포 특성)

  • Kim, Sung;Yoo, Jae-Myung
    • Korean Journal of Ichthyology
    • /
    • v.11 no.1
    • /
    • pp.72-85
    • /
    • 1999
  • A study on the larval fish assemblage around the front area was conducted in the Korea Strait in August, 1993. The front was found in the shelf break located in $35{\sim}36^{\circ}N$. A total of 125 species were found in the study area. Of these Engraulis japonicus was the most dominant species comprising 84.3% of the total fish larvae collected and followed by Maurolicus muelleri accounting for 7.7%. Gobiidae, Callionymidae and Pomacentridae showed higher frequency of occurrence. These five species can be divided into three groups. First group was comprised in the larval fish species such as E. japonicus and Callionymidae which were found in the whole study area. The second group was comprised of Gobiidae and Pomacentridae which were found in the warm area located in the southern part of the front area. The other species was M. muelleri found in the cold area located in the northern part of the front area including the front area. The assemblage, geological distribution and body length composition of the fish larvae in the Korea Strait would be mainly determined by the spawning ecology of the fishes, and the geological distribution and structure of the front which is formed in the ocean boundary between the Tsushima Current and the East Sea Cold Water.

  • PDF

Evaluation of Thermal Aging on PVC Using Thermo Gravimetry Analysis and Accelerated Thermal Aging Test (TGA와 가속열화를 이용한 전선 피복용 PVC의 열적 열화평가)

  • 박형주;김기환;김홍
    • Fire Science and Engineering
    • /
    • v.18 no.3
    • /
    • pp.45-50
    • /
    • 2004
  • Thermal degradation of PVC which used for insulator of 600V vinyl insulated wire has been studied by thermo gravimetry analysis and accelerated thermal aging test. The activation energy using thermo gravimetry analysis was determined by the kinetic methods, such as Kissinger and Flynn-Wall-Ozawa. The activation energy was determined to from 89.29 kJ/mol to 111.39 kJ/mol in 600V PVC insulated wire and from 97.80 kJ/mol to 119.25 kJ/mol in 600v heat-resistant PVC insulated wire. And also, the activation energy through a long-term thermal aging test was calculated by using Arrhenius equation In the low temperature of 8$0^{\circ}C$, 9$0^{\circ}C$, 10$0^{\circ}C$. The results showed that 600V PVC insulated wire was 92.16 kJ/mol, and 600v heat-resistant PVC insulated wire was 97.52 kJ/mol. Consequently, the activation energy of 600V heat-resistant PVC insulated wire is larger than 600V PVC insulated wire. Therefore, it can be predicted that 600V heat-resistant PVC insulated wire has a long-term stability relatively.

Study of the Characteristics and Crystal Growth of a shorted Wire by Overcurrent (과전류에 의해 단락된 전선의 결정성장 특성에 관한 연구)

  • Park, Jin-Young;Bang, Sun-Bae;Ko, Young-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.83-90
    • /
    • 2017
  • If an overcurrent exceeding the rated value is applied to an electric wire, the temperature of the electric wire increases, and the electric wire covering deteriorates to cause a short circuit. The upper limit temperature of the wire varies according to the magnitude of the overcurrent. When a short circuit occurs at each upper temperature limit, a cooling speed difference occurs during the solidification process due to the temperature difference between the short circuit temperature and the wire surface temperature. At this time, the pattern characteristics of the dendritic structure formed on the molten cross section are different. In this study, the upper temperature limit, which varied according to the overcurrent magnitude, was measured. At the time a short circuit occurred, the second branch spacing (dendrite Arm Spacing : DAS) of the dendrite was analyzed and the numerical value was quantified. The experimental results showed that the upper temperature limit increases with the magnitude of the overcurrent, and that the second branch spacing increases with increasing wire temperature.

저자 인터뷰-"조선민족혁명당과 통일전선" 펴낸 강만길교수

  • Jeong, So-Yeon
    • The Korean Publising Journal, Monthly
    • /
    • s.83
    • /
    • pp.13-13
    • /
    • 1991
  • 30년대 후반 이후 민족해방통일전선의 이론적 맥락과 그 구체적 활동을 세세히 추적하고 있는 이 책에서 강교수는, 이념적 노선에 있어서는 상대적으로 좌파를 대표하지만 이들의 통일전선의 궁극적 성격은 계급노선이 아닌 민족노선으로 파악해야 한다고 주장한다.

  • PDF

회원사 동향

  • Korea Electrical Manufacturers Association
    • 전기산업
    • /
    • v.7 no.4
    • /
    • pp.96-102
    • /
    • 1996
  • PDF

A Study on the Conductor of 80kV HVDC Transmission Line (80kV HVDC 송전선로 선종에 관한 연구)

  • Ko, Chun-Seog;Kim, Jae-Youl;Park, Hyung-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.451-452
    • /
    • 2015
  • 제주 ${\pm}80kV$ 가공선로는 다양한 가공송전선 중에서 송전용량을 증대시킬 수 있으면서도 기계적인 특성이 뛰어나고(이도특성 우수) 경제성이 있는(지지물 설치비용 및 운영 유지보수 비용 저렴) 전선을 고려하였다. 그 결과, 제주 ${\pm}80kV$ HVDC 가공선로 본선과 귀로선은 최종적으로 ACCC/TW 전선으로 선정하였다. 전선의 단면적은 교류와 직류를 동시에 운전하게 될 제주 시험선로의 특성을 고려하여 송전용량을 주안점으로 두어 154kV 교류 ACSR $330mm^2$에 송전용량에 상응하는 ACCC/TW 전선으로 도체 단면적 $160mm^2$ 전선을 채용하였다.

  • PDF