Thermal degradation of PVC which used for insulator of 600V vinyl insulated wire has been studied by thermo gravimetry analysis and accelerated thermal aging test. The activation energy using thermo gravimetry analysis was determined by the kinetic methods, such as Kissinger and Flynn-Wall-Ozawa. The activation energy was determined to from 89.29 kJ/mol to 111.39 kJ/mol in 600V PVC insulated wire and from 97.80 kJ/mol to 119.25 kJ/mol in 600v heat-resistant PVC insulated wire. And also, the activation energy through a long-term thermal aging test was calculated by using Arrhenius equation In the low temperature of 8$0^{\circ}C$, 9$0^{\circ}C$, 10$0^{\circ}C$. The results showed that 600V PVC insulated wire was 92.16 kJ/mol, and 600v heat-resistant PVC insulated wire was 97.52 kJ/mol. Consequently, the activation energy of 600V heat-resistant PVC insulated wire is larger than 600V PVC insulated wire. Therefore, it can be predicted that 600V heat-resistant PVC insulated wire has a long-term stability relatively.
Keywords
PVC(Polyvinyl chloride); Kissinger method; Flynn-Wall-Ozawa method; Activation energy; Arrhenius equation; Long-term thermal aging;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 David R. Lide, 'Handbook of Chemistry and Physics', CRC Press, pp464-633(1997)
2 Kissinger H. E., Anal. Chem., 29A, 1702(1957)
3 CIGRE-KOREA 한국케이블연구회, '2001년 전력케이블 심포지움', (2001)
4 Flynn J. H., Wall L. A., J. Res. Nat. Bur. Stand A Phys. Chem., 70A, 487(1966)   DOI
5 Chung-Seog Choi, 'The Properties Annalysis of 600V Grade Polyvinyl Chloride Insulated Wire with Variation of Thermal Stress', T. of Korean Institute of Fire Sci. & Eng., Vol. 15, No.1, pp108- 115(2001)
6 옥경재, 오종용, 박민영, 이춘하, '오염된 절연재료의 Tracking 특성에 관한 연구', 한국화재·소방학회, 춘계학술논문발표회논문집, pp204-209(2003)
7 최충석, 송길목, 김향곤, 김동욱, 김동우, '열적피로에 의한 전원코드의 발화 특성과 전기화재의 분석에 관한 연구', 한국화재·소방학회, 춘계학술논문발표회논문집, pp164-170(2003)
8 정창수, 이우선, 한재홍, '지중 배전케이블의 고장원인 분석', J. of KIEEME, Vol. 12, No.5, pp423-429(1999)
9 이미영, 구철수, 김복렬, 이영관, '가교폴리에틸렌의 열노화에 따른 구조와 물성의 변화', 폴리머, Vol. 27, No. 3, pp249-254(2003)
10 박홍태, 김경식, 남창우, 이규철, '전력케이블용 절연재료의 열화특성 및 수명진단에 관한 연구', J. of KIEEME, Vol. 12, No.1, pp11-17(1999)
11 전력연구원, '배전케이블 수명예측 기준결정 및 열화진단 시스템 구축', (1996)
12 한재홍, 송일근, 김주용, 이병성, 정종욱, '지중 배전케이블의 열화에 미치는 온수의 영향', J. of KIEEME, Vol. 15, No. 7, pp609-614(2002)
13 이승엽, 조대희, 이인호, 박완기, '통계적 기법을 이용한 전력케이블 절연층(XL-PE)의 수명예측', 한국전기전자재료학회, 춘계학술대회논문집, pp.57-61(1999)
14 산업자원부, '배선용 및 기기용 전선의 화재위험성에 관한 연구', (2001)
15 황병표, '2002년 전기재해 통계분석 - 전기화재를 중심으로', 전기저널, 제2호(2004)