• Title/Summary/Keyword: 전산화 단층 촬영

Search Result 1,092, Processing Time 0.029 seconds

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

Full mouth rehabilitation using 3D printed crowns and implant assisted removable partial denture for a crossed occlusion: a case report (3D 프린팅 금관과 임플란트 보조 국소의치를 이용한 엇갈린 교합의 전악 수복 증례)

  • Sung-Hoon Lee;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak;Ji-Man Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.367-378
    • /
    • 2023
  • With the recent development of computer-aided design-computer-aided manufacturing technology and 3D printing technology, and the introduction of various digital techniques, the accuracy and efficiency of top-down definitive prosthetic restoration are increasing. In this clinical case, stable occlusion support was obtained through the placement of a total of 9 maxillary and mandibular posterior implants in patient with anterior-posterior crossed occlusion. The edentulous area of the maxillary anterior teeth, which showed a tendency of high resorption of the residual alveolar bone, was restored with a Kennedy Class IV implant assisted removable partial denture to restore soft tissue esthetics. Computed tomography guided surgery was used to place implants in the planned position, double scan technique was used to reflect the stabilized occlusion in the interim restoration stage to the definitive prostheses, and metal 3D printing was used to manufacture the coping and framework. This clinical case reports that efficient and predictable top-down full mouth rehabilitation was achieved using various digital technologies and techniques.

Evaluation of Dose Variation according to Air Gap in Thermoplastic Immobilization Device in Carbon Ion (탄소입자 치료 시 열가소성 고정기구의 공기층에 따른 선량 변화 평가)

  • Ye-jin Na;Ji-Won Jang;Se-Wuk Jang;Hyo-Kuk Park;Sang-Kyu Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.33-39
    • /
    • 2023
  • Purpose: The purpose of this study is to find out the dose variation according to thickness of the air gap between the patient's body surface and immobilization device in the treatment plan. Materials and Methods : Four conditions were created by adjusting the air gap thickness using 5 mm bolus, ranging from 0 mm to 3 mm bolus. Immobilization was placed on top in each case. And computed tomography was used to acquire images. The treatment plan that 430 cGy (Relative Biological Effectiveness,RBE) is irradiated 6 times and the dose of 2580 cGy (RBE) is delivered to 95% of Clinical Target Volume (CTV). The dose on CTV was evaluated by Full Width Half Maximum (FWHM) of the lateral dose profile and skin dose was evaluated by Dose Volume Histogram (DVH). Result: Results showed that the FWHM values of the lateral dose profile of CTV were 4.89, 4.86, 5.10, and 5.10 cm. The differences in average values at the on the four conditions were 3.25±1.7 cGy (RBE) among D95% and 1193.5±10.2 cGy (RBE) among D95% respectively. The average skin volume at 1% of the prescription dose was 83.22±4.8%, with no significant differences in both CTV and skin. Conclusion: When creating a solid-type immobilization device for carbon particle therapy, a slight air gap is recommended to ensure that it does not extend beyond the dose application range of the CTV.

  • PDF

Arterio-Biliary Fistula as a Rare Life-Threatening Complication of Transjugular Intrahepatic Portosystemic Shunt: A Case Report (경경정맥 간내 문맥 정맥 단락술 후 드물게 발생하는 동맥-담관루: 증례 보고)

  • Ji Su Ko;Lyo Min Kwon;Han Myun Kim;Min-Jeong Kim;Hong Il Ha;Ji Won Park;Ji Young Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.705-711
    • /
    • 2022
  • A 46-year-old male with alcoholic liver cirrhosis underwent a transjugular intrahepatic portosystemic shunt (TIPS) for refractory ascites. On the 9th day after the procedure, he presented with melena and decreasing hemoglobin levels. Hemobilia due to fistula formation between the right intrahepatic bile duct and right hepatic artery was suspected on computed tomography. Angiography revealed a fistula of the small branches of the hepatic segmental arteries, and right intrahepatic bile duct was confirmed; embolization was successfully performed with a coil for the eighth segmental hepatic artery, a glue-lipiodol mixture for the fifth segmental hepatic artery, and gelfoam slurry for the right anterior hepatic artery. However, 2 days after embolization, the patient died owing to aggravated disseminated intravascular coagulopathy. When gastrointestinal bleeding occurs after TIPS, careful evaluation is immediately required, and hemobilia should be considered.

Successful Transcatheter Arterial Embolization following Diverticular Bleeding in the Third Portion of the Duodenum: A Case Report (경동맥 색전술을 이용한 십이지장 3부 게실 출혈의 성공적인 지혈: 증례 보고)

  • Seok Jin Hong;Sang Min Lee;Ho Cheol Choi;Jung Ho Won;Jae Boem Na;Ji Eun Kim;Hye Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.237-243
    • /
    • 2021
  • This is a rare case of a 73-year-old male patient who presented with hematochezia and was treated using transcatheter arterial embolization following upper gastrointestinal bleeding in the third portion of the duodenum. The cause of the bleeding was not found on gastrointestinal endoscopy and CT. On the third day of hospitalization, the hemoglobin level continued to decrease. A technetium-99m-labeled red blood cell scan revealed suspicious bleeding in the diverticulum of the third portion of the duodenum. Superior mesenteric artery angiography showed active bleeding from the posteroinferior pancreaticoduodenal artery, which was embolized with N-butyl cyanoacrylate. The patient was discharged on the seventh day after embolization without re-bleeding or complication. We report a rare case of a patient with active bleeding from a duodenal diverticulum that was difficult to diagnose using routine modalities. Herein, we report a rare case of a patient with active bleeding from a duodenal diverticulum that was difficult to diagnose using routine modalities. We also conducted a relavant literature review.

Ultrasound-Guided Percutaneous Thrombin Injection of Femoral Artery Pseudoaneurysms Caused by Vascular Access (대퇴동맥을 통한 시술 후 발생한 가성동맥류의 초음파 유도하 경피적 트롬빈 주입 치료)

  • Seung Yoon Chae;Chan Park;Jae Kyu Kim;Hyoung Ook Kim;Byung Chan Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.589-599
    • /
    • 2021
  • Purpose To analyze the success and complication rates and factors associated with technical failure of the ultrasound (US)-guided percutaneous thrombin injection of femoral artery pseudoaneurysms caused by vascular access. Materials and Methods Records of 30 patients with post-catheterization femoral artery pseudoaneurysms who had been treated with US-guided percutaneous thrombin injections in the department of radiology between March 2009 and June 2019 were retrospectively analyzed. The lesion was diagnosed based on US or contrast-enhanced CT. The characteristics of the patients and their lesions were analyzed. Results The mean patient age was 67.8 years. The mean diameter of the pseudoaneurysmal sac was 20.88 mm (5-40 mm). Twenty patients (66.6%) obtained complete thrombosis after the primary injection, while 10 patients (33.3%) obtained partial thrombosis. The number of patients with a low platelet count (< 130 k/µL) was significantly higher in the partial thrombosis group than in the complete thrombosis group (p = 0.02). No substantial procedure-related complications were found in any patient. Conclusion The US-guided percutaneous thrombin injection is considered an initial treatment option for pseudoaneurysms caused by vascular access because of its safety and efficacy.

Epipericardial Fat Necrosis in a Pediatric Patient Diagnosed Using Contrast-Enhanced MRI Findings: A Case Report and Literature Review (소아 심장막 주위 지방 괴사 환자에서의 조영증강 자기공명영상 소견: 증례 보고 및 문헌고찰)

  • Seong Ju Kim;Byoung Hee Han;Youngjong Cho;Dae Shick Ryu;Ga Young Yoon;Wooyul Paik;Young Rae Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1160-1167
    • /
    • 2022
  • Epipericardial fat necrosis (EPFN) is a relatively rare cause of acute chest pain, with only five pediatric cases having been reported in the English-language medical literature to date. EPFN can be diagnosed based on the clinical symptoms of acute pleuritic chest pain and classic CT features of typically ovoid fatty lesions surrounded by a rim or capsule in the mediastinal or pericardial areas. Previous studies have reported that contrast-enhanced MRI can detect typical fat signal changes in adults with EPFN. We report a pediatric EPFN case diagnosed using gadolinium-enhanced MRI. Thus, contrast-enhanced MRI may be used to confirm EPFN in the differential diagnoses of the causes of acute chest pain.

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.

Clinical and Radiological Findings of Coronavirus Disease 2019 Pneumonia: 51 Adult Patients from a Single Center in Daegu, South Korea (Coronavirus Disease 2019 폐렴의 임상적, 영상의학적 소견: 대구의 단일 기관에서 51명의 성인 환자를 대상으로 한 분석)

  • Seung Eun Lee;Young Seon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.591-603
    • /
    • 2020
  • Purpose The purpose of this study was to describe the clinical features and chest computed tomography (CT) findings of coronavirus disease 2019 (COVID-19) pneumonia. Materials and Methods An Institutional Review Board-approved retrospective review was performed for 51 laboratory-confirmed COVID-19 pneumonia patients. Patients were divided into two groups depending on their clinical status: mild and severe. Clinical characteristics and chest CT findings were compared between the two groups. Results Among the 51 patients (22 men, 29 women; mean age, 56.5 ± 16 years; range, 22-88 years), 37 (72.5%) were in the mild group and 14 (27.5%) were in the severe group. The patients in the severe group (68.7 ± 12.5 years) were older than the patients in the mild group (51.8 ± 14.9 years, p < 0.001). Premorbid conditions and decreased lymphocyte counts were more often observed in the severe group than in the mild group (71% vs. 41%, p = 0.049 and 86% vs. 32%, p = 0.001, respectively). On chest CT, most patients exhibited a mixed ground-glass opacification (GGO) with consolidation (76%) or a GGO (22%) pattern. The majority of lesions were predominantly bilateral in the lower lung with a posterior, peripheral distribution. The patients in the severe group had higher severity scores than those in the mild group. Conclusion Patients with laboratory-confirmed COVID-19 pneumonia have typical chest CT findings that provide important information regarding expected disease severity.

Atypical Presentation of Chronic Granulomatous Disease in a Neonate with a Pulmonary Granuloma Mimicking a Tumor: A Case Report (신생아에서 종양으로 오인되는 폐 육아종의 비전형적인 소견을 보인 만성 육아종성 질환: 증례 보고)

  • Young Jin Yoo;Joo Sung Sun;Jang Hoon Lee;Hyun Joo Jung;Yeong Hwa Koh;Joonho Jung;Hyun Gi Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.4
    • /
    • pp.990-995
    • /
    • 2020
  • Chronic granulomatous disease (CGD) is an uncommon primary immune deficiency caused by phagocytes defective in oxygen metabolite production. It results in recurrent bacterial or fungal infections. Herein, we present a case of CGD with a large pulmonary granuloma in a neonate and review the imaging findings. The patient was a 24-day-old neonate admitted to the hospital with fever. A round opacified lesion was identified on the chest radiograph. Subsequent CT and MRI revealed a round mass with heterogeneous enhancement in the right lower lobe. There were foci of diffusion restriction in the mass. Surgical biopsy of the mass revealed chronic granuloma. Finally, the neonate was diagnosed with CGD caused by mutation of the gp91phox gene. Herein, we present the clinical and imaging findings of this unusual case of CGD.